LaserShield Instant Security System Скачать руководство пользователя страница 9

HOW TO SET UP YOUR SYSTEM

LaserShield

®

Instant Security System

OWNER’S MANUAL                Page 9

SECTION TW

O

Where to Position the 
Wireless Detection Unit

• Across from the 

main entry area

• 4-6 feet off the floor

(optimal height is 5 feet)

• Unobstructed view

Position Your Wireless Detection Unit

Positioning the Wireless Detection Unit

Place the WDU in a corner, aimed in the
direction a burglar would have to pass to enter
areas of your home or business. Optimum
height for the WDU is 4-6 feet. Typically,
higher placement of the WDU increases range
and distance. Obstructions such as furniture,
columns or narrow corridors can impair the
range of detection. Place an additional WDU
in a master bedroom, as burglars tend to
frequent this room.

You can check the area of coverage by
watching the red light in the motion sensor
window, which will flash on and off as you
move.

Adjust the location and position of the WDU to
obtain the best coverage. Avoid aiming motion
sensors directly at heating or air conditioning
registers or large panes of non-draped glass.
Large glass areas that receive direct sunlight
can trigger an alarm condition. Do not arm the
System when it is placed in a room with
windows left open. Motions sensors do not
see through glass so if windows are closed
the System will not be disturbed by outside
activities, such as pets, and gardeners.

Pet Owners: Please refer to page 18 "Using
LaserShield

®

with Pets".

Plug MAU into Power

Plug the AC Power Adapter (supplied) into the
wall and insert the DC connector into the
power jack located on the back of the Master
Alarm Unit.

Push and hold the Power Button on the MAU
until the voice says "LaserShield on." 

Setting up the Wireless Detection Unit
(WDU)

The WDUs communicate wirelessly with the
Master Alarm Unit. They require only an AC
Power connection (supplied). They do not
require a telephone connection. WDUs can be
placed on nightstands, tables, bookshelves or
anywhere you have a convenient non-
switched power receptacle. All WDUs offer the
best coverage pattern when placed in a
corner of a room.

Note:

The annunciator may refer to the WDUs

as "satellite units."

The Wireless Detection Unit features include:

Motion Sensor
Bypass Button to deactivate an individual unit
Panic Button
Battery Back-up

Activating your Wireless Detection Unit

Plug unit into a non-switched power
receptacle.
Press the power button until the red power
light goes on and remains on.
Follow instructions linking your WDU in 
the "Using Learn Mode to Link Devices" on
page 13.

1.

2.

3.

Recommended Placement 

for the WDU

Содержание Instant Security System

Страница 1: ...100503 5 L a s e r S h i e l d I n s t a n t S e c u r i t y S y s t e m OWNER S MANUAL...

Страница 2: ...r LaserShield HOW TO SET UP YOUR SYSTEM Remove the Battery Protection Strip 8 Position the LaserShield Master Alarm Unit 8 Connect the Telephone Line 8 Connect the Power 9 Activate the Wireless Detect...

Страница 3: ...Remote 17 Section FOUR Additional Features Household Pets the LaserShield Pet Shield 18 Managing the System by Telephone When You Are Away 19 False Alarm Protection Features 20 Loss of AC Power and Lo...

Страница 4: ...apartments condominiums or offices may only need the LaserShield Starter Kit to achieve adequate protection You may expand your LaserShield Instant Security System to other rooms with additional Wirel...

Страница 5: ...monitors your alarm for round the clock protection Operate your LaserShield Instant Security System using the Keychain Remote or by phone Test your System with Rapid Response Monitoring Service RRMS...

Страница 6: ...m permit If your community or local law enforcement agency requires an alarm permit and you operate your alarm without a permit you could be subject to fines law enforcement non response and or deacti...

Страница 7: ...Owner s Manual Product Registration Card 2 Emergency Cards Pet Shield Quick Start Guide Activation Incentive Card Additional Keychain Order Form LASERSHIELD INSTANT SECURITY SYSTEM INCLUDES Wireless D...

Страница 8: ...ough a PBX please contact LaserShield Customer Care for assistance Connecting through a PBX or other telephone switching system may prevent or reduce reliability in reporting alarm events to RRMS Plug...

Страница 9: ...a room with windows left open Motions sensors do not see through glass so if windows are closed the System will not be disturbed by outside activities such as pets and gardeners Pet Owners Please ref...

Страница 10: ...f the MAU The MAU will verbally announce Learn mode Next on each Keychain Remote and WDU press the Panic Button to link the unit The MAU will announce each unit linked When the MAU has announced a uni...

Страница 11: ...Rapid Response Service Monitoring Agreement and Information Form If you don t have access to the Internet you may Fax or Mail the enclosed Rapid Response Monitoring Service Agreement and Information...

Страница 12: ...iately If you use fax or mail to activate your monitoring service wait until a LaserShield Customer Care representative calls you to begin your test Press a panic button on your Keychain Remote MAU or...

Страница 13: ...ering the alarm If a Keychain Remote is lost you will need to deactivate all your remote devices and then re link the devices you still have How to Unlink All Your Remote Devices Press the Learn butto...

Страница 14: ...In case of an alarm RRMS will ask you for your personal Passcode Every authorized person in your household or business must have a copy of the Passcode It is also required to activate your monitoring...

Страница 15: ...second time to force arming overriding the condition Checking the MAU System Status If the amber status light on the MAU is blinking it means there is an abnormal system condition You can use your Ke...

Страница 16: ...hich will set off your siren and dial RRMS if you have activated monitoring from your Keychain Remote the MAU or any WDU MAU press RED Panic Button on top of unit until the siren sounds Wireless Detec...

Страница 17: ...ken door or window vulnerable to vandalism weather and other unwanted intruders Note You may update your emergency contact information at anytime using the Internet or by contacting Customer Care Reme...

Страница 18: ...and dogs jump on furniture place your WDU at a height where pets can move safely beneath the detection area You can aim the coverage of your WDU by watching the test light inside the motion sensor win...

Страница 19: ...to turn on the room monitoring microphone to listen to activity in the room You can also make some refinements in how your System works via touch tone phone You can disable Call Waiting and set your...

Страница 20: ...ery Detection The System will attempt to report a MAU low battery condition to Rapid Response Monitoring Service RRMS You may be contacted by e mail or mail if your alarm reports multiple low battery...

Страница 21: ...s to beep until the siren sounds Let the siren sound for a full 10 seconds Disarm the alarm using your Keychain Remote To test panic button simply press the panic button on any device you wish to test...

Страница 22: ...eb site Please recycle old batteries They may be recycled at retail electronics stores or at a local battery recycling location Do not dispose of batteries in landfills For more information on recycli...

Страница 23: ...s plugged into the back of the MAU Check for phones off hook Repeat the DISARM command If the problem continues please contact Customer Care The MAU reports NO PHONE LINE Repeat steps for unreported a...

Страница 24: ...you have an alarm system LaserShield offers remote control of your alarm using a secret passcode included with your unit and any remote telephone or cellular phone This passcode allows you to phone yo...

Страница 25: ...ons for those with sight difficulties There is also a protruding dot in the plastic over the WDU and MAU on off power buttons to make them simple to find by touch Keychain Remote buttons are shaped di...

Страница 26: ...Y LIABILITY Page 26 LaserShield Instant Security System OWNER S MANUAL SECTION EIGHT LaserShield s Warranty and Limitation of Liability are set forth on the Limited Warranty provided in this package w...

Страница 27: ...with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation...

Страница 28: ...6 618 4336 if you have any questions LaserShield Security Systems Inc LaserShield Customer Care c o Accent 645 Park East Boulevard New Albany IN 47150 Visit us on the Internet www lasershield net 2003...

Отзывы: