SPECIFICATIONS
LaserShield
®
Instant Security System
OWNER’S MANUAL Page 27
SECTION EIGHT
Operating Environment
Temperature
+41º F to +122º F (+5º to +50º C)
Humidity
0% to 95% relative humidity (non-condensing)
Storage Environment
Temperature
+32º F to +140º F (+0º to +60º C)
Humidity
0% to 95% relative humidity (non-condensing)
Communications
Telephone jacks
RJ-11
Dialing capability
Tone
Power Supply
Batteries
Master Alarm Unit: 6 V 1.2 Ah, sealed lead-acid, rechargeable
Wireless Detection Unit: WDU: CR123A Lithium
Keychain Remote Control: CR2032 Lithium
Power adapter
Input: 100-240VAC, 50-60 Hz.
Output: 10 V DC, 500mA
Safety
Approvals
FCC Part 68 FCC Part 15
Use only supplied UL approved power adapter
Manufacturer’s Declaration of Conformity
We declare under our sole responsibility that LaserShield
®
, to which this declaration relates, is in conformity with the
following standards or other normative documents:
Federal Communications Commission (FCC) Compliance Notice: Radio frequency Notice:
DECLARATION OF CONFORMITY
We, Lasershield Systems, Inc.
5931 Sea Lion Place, Suite 114
Carlsbad, CA 92008 USA
+1 (760) 930-1908
declare under our sole responsibility that the Master Alarm Unit, model number BSK-0013101 complies with Part 15 of FCC
Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
The devices
• Wireless Detection Unit, model number WDU-0013301
• Keychain Remote, Model, model number KCR-0011501
comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct
the interference by one or more of the following measures:
— Reorient or locate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
Any modifications to the unit, unless expressly approved by LaserShield
®
Systems, Inc., could void the user's authority to
operate the equipment.
Consumer Information and FCC Requirements
Telephone connection:
This equipment complies with Part 68 of the Federal Communications Commission rules. These rules permit this device to
be directly connected to the telephone network. Standardized jacks are used for these connections. This equipment
should not be used on party lines or coin lines.
If the device is malfunctioning, it may also cause harm to the telephone network; this device should be disconnected until
the source of the problem can be determined and until it has been repaired. If this is not done, the telephone company
may temporarily disconnect your service.
If the telephone company requests information on what equipment is connected to their lines, inform them of:
• The telephone number this unit is connected to
• The ringer equivalence number, for the Master Alarm Unit is 1.
• The FCC registration number that appears on the bottom of the unit.
•
•
•
•
•
•
•
•