7.4 Remote Test and Reset
Headers are provided that allow for remote testing and resetting of the mismatch detector. For
example, a key-operated switch could be connected to the headers so that when it is set one way it
tests the mismatch detector, and when set the other way resets it. The key is then returned to the
mid position and removed to allow normal operation to resume.
The two headers are shown on the diagram above. For convenience, a single four-way 0.1” pitch
connector can be connected across the two headers so that a four-core cable can be run to the
remote switch unit.
The ‘test’ switch should have a contact which is normally closed, and which opens to perform the
test. The ‘reset’ switch should have a contact which closes to reset the detector.
Contact Lasermet or your local distributor for assistance if you wish to use these features.