![Lasermet ICS-6 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/lasermet/ics-6/ics-6_instruction-manual_678408018.webp)
ICS-6 Instruction Manual
01000-53-000
Page 18 of 42
Issue 11 19 January 2021
5.4 Interlock Operator Output Contacts
The ICS-6 has three volt-free interlock operator output contacts which may be used for various
purposes including:
Switching laser power;
Controlling beam shutters;
Operating the laser’s interlock input;
Controlling door locks.
There is a 9-contact upgrade option should three contacts prove insufficient, please contact
Lasermet or your local distributor if this is required. The wiring space is very constrained when the 9-
contact board is fitted, and it is normally recommended that the deep-case option is also selected
which increases the overall depth of the ICS-6 from 89mm to 145mm.
5.4.1
Laser Power Supply
With this option, the laser mains supply is only switched on when the Arm Laser button is pressed.
This option may be suitable for smaller lasers. For larger lasers the interruption of the supply may
not be recommended as there may be a complicated and time-consuming restart sequence before
the laser is ready for use after tripping. If in doubt check with the supplier/manufacturer of the laser.
To avoid risk of shock always ensure the mains supply is isolated before making these connections.
The contact is rated at 6A resistive load maximum. If the laser mains supply requirement exceeds
the capability of the ICS-6, please contact Lasermet who can provide an enhanced version equipped
with monitored safety contactors for switching higher powers.