Verify that any override devices operate correctly from both sides of the door and that the door can
be opened without disarming the system while the override is in force. Check that any time function
(e.g. O-PCB or ICS-KP12 keypad) operates and times out after the desired time delay, and that if the
door is left open beyond the time delay the system is disarmed. Check that overrides in the B area
are indicated by a red light on the Switch Unit, and not on the B ICS.
Check that any illuminated signs indicate correctly when the system is armed and disarmed.
Confirm that the opening of doors in one area does not cause the other area to be disarmed.
Confirm that the activation of any override in one area does not defeat any interlocks in the other
area.
Confirm that the output of the ICS only operates when the relevant ICS is armed and that the output
of one ICS is not activated by the arming of the other.
5.2 One-Room Mode
Set the room divider open.
Set all doors closed and confirm that the B area ICS cannot be armed.
Check that the Switch Unit indicates ‘One-Room Mode’.
Perform the tests described in ‘Two-Room Mode’ above in one-room mode using the A area ICS and
check that all equipment in both halves of the room operate correctly as a single interlocked room,
and that all overrides and signs operate as required.
Confirm that any overrides allow access through the required doors and that the override is correctly
indicated on the A area ICS and Switch Unit.
Check that when the system is armed the correct outputs operate and the correct devices are
enabled, and that any outputs that should not work when the system is armed are disabled.