Technical data
Measurement principle
Resistive material moisture measurement
by way of integrated electrodes
Modes
2 wood groups
3 building materials
Test mode
Materials /
Measurement range
Cement screed: 1% ... 4,5%
Gypsum plaster: 0.1% ... 38.2%
Cellular concrete: 2.2% ... 99%
Wood: 5% ... 99%
Accuracy (absolute)
Wood:
± 1% (5% … 30%)
± 2% (<5% and >30%)
Building
materials:
± 0.15% (0% ... 10%)
± 1% (>10%)
Operating conditions
0°C…40°C, Max. humidity 85% rH,
no condensation, Max. working
altitude 2000 m above sea level
Storage conditions
-10°C…50°C, Max. humidity 85% rH
Power supply
1 x 6LR61, 9V
Dimensions (W x H x D)
57 x 120 x 44 mm
Weight (incl. battery)
146 g