If the unit is currently outside of its automatic levelling range (> 3.5°),
a warning signal will sound and the prism head will not rotate. The
unit must then be placed on a surface which is closer to level. When
in vertical use, the unit does not level itself automatically.
!
Horizontal use of AquaPro
– Set up the unit on a surface that is as level as possible or fasten it to a
tripod.
– Turn the transport lock (G) in the arrow‘s „Unlock“
direction to its limit.
This releases the locking mechanism that protects the pendulum during
transport.
– Press the On/Off button (A).
– Within its range of +/- 3.5°, the unit will level itself automatically and
the prism head will begin to turn.
– The speed of rotation can be changed with the selector button (B),
H = 600 RPM, M = 400 RPM, L = 200 RPM.
Vertical use of AquaPro
– Turn the transport lock (G) in the arrow‘s „Lock“ direction to its limit.
– Hook the vertical/wall bracket into its receptacle (O). To do this, the locking
lever (L) must be in its lower position and the bracket must latch audibly.
To release the bracket, press the locking lever (L) down.
– Align the unit with the adjustment foot (J) as indicated by the vertical
spirit level (F).
– Press the On/Off button (A). The prism head will begin to rotate.
– The speed of rotation can be changed with the selector button (B),
H = 600 RPM, M = 400 RPM, L = 200 RPM.
Always activate the Out-Off-Level function for horizontal levelling.
This is active when the unit is switched on and the transport lock is
turned to its „Unlock”
position. If the unit is currently outside of
its automatic levelling range (> 3.5°) , a warning signal will sound and
the prism head will not rotate. The unit must then be placed on a
surface which is closer to level.
!