Ref:.. \operat98\instructions 11\775600.qxp 19-01-11
©York Survey Supply Centre 2010
Tilt Alarm Function
FL60 Maxi Liner is equipped with an automatic TILT function. If level of a laser level is disturbed the instrument will
readjust itself (within the self levelling range). If level is disturbed at large range a height offset will be caused.
This will be avoided by the TILT function.
The instrument will shut off even within the self-levelling range.
Approx. 1 minute after FL60 has been switched on the TILT-Function will be activated automatically.
The red LED indicates that TILT-function is activated. If the level is now disturbed the unit will not read-
just itself (the lines are blinking)
To deactivate TILT-function press TILT-button again.
Technical Data
FL60
Automatic levelling range
±3°
Accuracy
±1mm / 10m
Operating Range
without receiver
Ø 20m *
*depending on surrounding
with receiver
Ø 80m *
& average light conditions
Fan angle Hz-Lines
130° each
Operating Time / Power Supply
12h NiMH
or
24h Alkaline
Temperature Range
-10° to +40°C
Visible Laser Diode / Laser Class
635nm / 2M
Receiver FR44
Indication
front: LCD-Display
side: LED
Accuracy
± 1mm
Tones
3
Operating Time / Power Supply
100h (1 x 9v)
FL 60 Maxi Liner
Code: 775600
Operating
Instructions