background image

 

JOBSITE CALIBRATION CHECK 

(Recommend performing calibration check once a week at minimum) 

 
 

1.

 

Using the trivet mount or tripod, get the Quad 1000HDU precisely over your reference 
point on the ground floor.

 

 

2.

 

Place the target / template precisely centered on the laser spot at the highest point 
possible above the Quad 1000HDU. (At least 100 feet if possible) Secure the target so it 
will not move.

 

 

3.

 

Rotate the Quad 1000HDU 180°; If using a tripod, make sure you are still positioned over 
your reference point.

 

 

4.

 

Go back to the target and measure any change of the laser spot relative to the bulls-eye 
target.

 

 

 Given the dynamics and movement of structures due to temperature, wind, loads etc., the 
target relation to the Quad 1000HDU laser may be moving and not providing a constant. This 
should definitely be taken into consideration so as a result, depending on conditions, you could 
be getting readings of 

 1/16 or 

 1/8 at the target per 100 vertical feet. If you are not 

comfortable or confident with the field calibration check, have it checked by your Dealer 
Service Department. 
 
 

 
MAINTENANCE

 

The Quad 1000HDU requires no maintenance other than periodically cleaning the laser output 
lens. Use a soft cloth with Windex or alcohol. 

*NOTE: Laser must be turned OFF when cleaning the lens! 

 
 

CERTIFICATION 

USA EN/IEC 60824-1 2007 Class 3R 
 
 

LASER SAFETY 
Laser Light-Avoid Direct Eye Exposure 

The maximum power output of this laser is less than 5mw. A laser safety kit is supplied with the Quad 
1000HDU laser. The kit contains operator qualification cards and a sign that should be posted near the 
laser whenever it is in use.  
 
Observe the following rules: 
 

 

Never look directly into a laser beam or point the beam into the eyes of others. Set the laser at a 
height that prevents the beam from shining directly into people’s eyes. 

 

DO NOT remove any warning signs from the laser. 

 

Only properly trained people are to use this product. 

 

Service to be performed only by factory trained personnel; unit contains no user serviceable 
parts. 

 

 

Содержание QUAD 1000HDU

Страница 1: ...1041 Rev 2 28 19 VERTICAL CONTROL LASER OWNERS MANUAL 1810 SE First Street Suite H Redmond OR 97756 Phone 541 548 0882 Fax 541 548 0892 Email laserline laserline net Website www laserlinemfg com Rev...

Страница 2: ...000HDU laser 2 Alignment Targets P N 4001 0010 Ultra bright bulls eye for the most visible and precise readings at any distance Targets feature laser pass through allowing multiple readings at one tim...

Страница 3: ...r the purpose of providing plumb control for your project It also features a short range downward shooting laser beam that is used like a plumb bob or optical tribrach to easily get directly over your...

Страница 4: ...the Quad has self leveled to within its operating spec the plum bob laser comes on steady and the long range upward Zenith shooting laser beam is activated Self leveling time is normally under ten sec...

Страница 5: ...e duration of the job Do not move the Quad 1000HDU up from floor to floor as the building progresses This can create compounding errors USING THE TRIVET MOUNT This is the preferred method It keeps the...

Страница 6: ...he target center that allows the center of the laser spot to pass through so that more than one target can be used at the same time E There are two mounting holes in each target to allow for custom mo...

Страница 7: ...r 1 8 at the target per 100 vertical feet If you are not comfortable or confident with the field calibration check have it checked by your Dealer Service Department MAINTENANCE The Quad 1000HDU requir...

Страница 8: ...Identification and Certification Non Interlocked Warning Label Top Explanatory and Warning Label Hazard Symbol Aperture Label Bottom LABELS Required for this product Aperture Label Top...

Страница 9: ...SA EN IEC 60824 1 2007 Class 3R International IEC 60825 1 2014 Class 3R USA OSHA compliant Meets all Federal and International standards Power source 12 VDC or 110 220 VAC with optional 1140 power con...

Страница 10: ...always check for accuracy per the enclosed instructions in this manual Warning Under no circumstances attempt to open or disassemble the Laser Housing Doing so may cause exposure to potentially hazar...

Страница 11: ...NOTES...

Отзывы: