SETTING UP
A)
Set the tripod over your point on the ground floor with the head fairly level.
B)
Attach the Quad1000HDU to the tripod with the 5/8
x 11 bolt. (Snug only, do
not over tighten)
C)
Power up the unit.
D)
Level the bulls- eye bubble on the Quad 1000HDU by adjusting the tripod legs
up or down.
E)
Loosen the 5/8
x 11 attachment bolt and slide the Quad 1000HDU until the laser
plumb-bob is directly over your point. Re-tighten attachment bolt to snug.
USING A TRIPOD:
(Standard Flat Head with 5/8
x 11 Attachment)
Tripod leg adjustment for leveling
the bulls- eye bubble
Note:
Always set the Quad 1000HDU on the ground floor or lowest floor possible and leave it in that location for the duration
of the job
.
Do not move the Quad 1000HDU up from floor to floor as the building progresses. This can create compounding
errors.
USING THE TRIVET MOUNT:
(This is the preferred method)
It keeps the instrument low to the deck and closer to your
reference point. Also, since the unit is only inches off the ground, it won’t be so vulnerable to getting knocked over like with a
tripod.
A.
Attach the Quad 1000HDU to the quick disconnect rotational receiver mount.
B.
Place the trivet over your reference point on the ground floor.
C.
Level the Quad 1000HDU bulls-eye bubble by using the 3 adjustable leveling bolts on the trivet mount.
D.
Power up the Quad 1000HDU and allow it to self-level. The plumb-bob laser will blink until it has leveled.
E.
Once leveled, slide the trivet until the plumb laser is directly over your point. The instrument is now projecting a
beam reference at Zenith
Содержание QUAD 1000HDU
Страница 11: ...NOTES...