TEST SMS
Testing the operation of the unit and of the
transponder
If the TRA200 is not turned on, we will receive an
SMS alerting us that the Tag is absent.
17
TEST
SMS command:
TEST or TEST + phone number for test
If only the TEST command is sent, the message will be sent
to the authorized numbers. If a new number is entered after
TEST, the message will be sent to the indicated number
only. The procedure allows you to test the correct
connection of the transponder to the device and it is
possible to simulate an alarm warning.
Testing only possible in PROGRAMMING mode
(GREEN LED of the unit turned on for 30 seconds)
NOTE:
If the LED is off, you can switch the system to PROGRAMMING mode by pressing
the RESET button of the unit. (see dedicated chapter)
Warning! When you receive the SMS OK, send a new
message “Stop2” as suggested in the message
received, in order to stop the alarm simulation.
Stop2
LED
Turn on the transponder by pressing the button for
5 seconds, until the LED lights up, release the
button and repeat the TEST by sending an new
text message.
Press for 5
seconds
IMPORTANT:
when the SMS message is received, the unit turns off the GREEN LED and
waits for the transponder connection. Upon recognizing it, the GREEN LED lights up and
sends the text message.
OK