REAR unit setting
41
Volume of rear LED indicator
volume
OFF
00
LOW
volume
01
(
)
02
factory setting
- FS
HIGH volume
for BZ model
42
Orientation of rear LED indication
(
)
00
FS
standard
change
left
and
right
side
01
43
Sensitivity of rear sensors
=
-9 - +9
FS
00
45
Range of rear central sensors
Above
100cm
display
120 - 180
FS
[cm]
= 160
shows 10 - 12
46
Range of rear corner sensors
[cm]
=
45 - 90
FS
65
47
Range of rear central sensors STOP zone
[cm]
=
Above
100cm
display
30 - 120
FS
35
shows 10 - 12
40
Number of rear sensors connected
=
02,03,04 FS
04
48
Range of rear corner sensors STOP zone
[cm]
=
30 - 90
FS
35
49
Suppression of rear protruding parts (spare wheel, hook)
(
)
00
FS
function disabled
05,10,15,20,25,30
exclusion of the protruding parts from bumper in Cm
99
automatic exclusion of the protruding parts
!!! NOTE:
change only if there is an overhang, eg. spare whell or other, increase
the value until the protrusion is no longer detected by the parking system.
52
Detection of very close obstacles
00
FS
(
)
not active
active
01
54
Acoustic signal timed of an obstacle in the R1, R2 and R3 areas
01
disabled function after 1 second
02, 03 - 10
timing, in step of operation sensors (seconds)
99
(FS)
constant signalling of obstacles
55
Delay of rear sensors activation
(
)
00
FS
vehicle with manual transmission
vehicle
with
automatic
transmission
01
56
State of rear sensors after turn ON
(FS)
00
all sensors active
everse
gear
command
01
R
for WIFI module (EPSKEY)
(operation with the connection of the yellow / Blue pin.7)
57
Dealay of rear sensors deactivation - time window
-
[s]
=
(it’s
necessary
that
control
unit
is
00
0
FS
3
00
powered through starting key)
60
State of rear sensors with connected trailer socket “pin 6" (negative command)
eactivated
(
)
00
FS
sensors d
STOP
zone
of
rear
sensors
is
set
according
parameters
61,
62
01
61
Range of rear central sensors STOP zone with bike carrier (pin 6 to ground)
[cm] =
100 - 130
FS
100
62
Range of rear c
sensors STOP zone with bike carrier (pin 6 to ground)
orner
[cm] =
100 - 130
FS
100
PARAMETERS SETTING
Pag.22