LaserBit PicoPlus Series 1.0                                     page     

18 

9 System 

installation 

 

9.1  On the table test 

 

Warning!

 Do not look either into the transmitter or the receiver optics because at 

this distance even the reflected laser beam 

can

 be dangerous to your eyes. 

Operating the system on much shorter distance than presumed originally can cause 
saturation or even permanent damage to the receiver. Always use optical 
attenuators for this kind of test. 
The on-the-table test needs careful planning and careful use during the test period. 
The units should be placed at about 2 m distance from each other with optical 
windows facing one another. Put an appropriate optical attenuator (Attenuating foil 
or cardboard with several small holes) between the heads. Make all the necessary 
connection as described below to connect your network equipment (computer or 
protocol analyzer) to the heads and power up the units. Turn ON the Outdoor 
Interconnection Units and check if the power LED is ON on the head. 
You should be able to align the units without any tool and get full received level on 
the signal strength LED’s. Make sure that the “Saturation” indicator is OFF. Adjust 
your attenuators if necessary to avoid saturation of the receivers. 
 
Please note that at this short distance, specially the longer distance links can reflect 
to the remote site or even to the same head. If you experience full receiving level, 
with no traffic throughput, in that case try to move the heads slightly units out of the 
reflection zone.  

 
Please also take in consideration that the laser beam is concentrated and in such a 
short distance can harm your eyes, every time you test the units on short distance, 
do it with extra care. Never look into the sighting device if the remote laser is turned 
on. We strongly suggest to double check the power connection before you turn on 
the device. Handle the power connection with extra care. Safety first. 
 
After obtaining the desired received level, check the data connection between 
devices. Using computers or appropriate testing devices. 
On the table tests are perfect for troubleshooting (If there is a transmission problem, 
check the status of the connecting devices (e.g. Link signal or cable polarity) and 
cables.) in a controlled area. If you experience some problems during the test, 
please try to test the connected equipments with a direct connection.  

 

Содержание PICO Plus Series

Страница 1: ...PICO Plus Users Manual 1 0...

Страница 2: ...on ____________________________________________ 13 6 2 Preferred installation sites __________________________________________ 13 6 3 Distance measurement _____________________________________________...

Страница 3: ...FSO systems use a laser diode as a light source and a receptor diode photo diode to receive the signals coming from the laser diode from the transmitter side But the basic elements are still the same...

Страница 4: ...ction across rivers and other natural or artificial obstacles where cable is not available The transmission technique used in the Laserbit FSO devices provides transparent and wire speed data transfer...

Страница 5: ...l is amplified encoded and then drives the laser diode The transmitter optics assures the proper beam shape and controls the beam divergence The receive optics perceives and directs the transmitter si...

Страница 6: ...se are Areas with natural or artificial obstacles Where cable is actually not an alternative like across rivers or railways or in rugged terrain Urban areas Where only leased lines are available with...

Страница 7: ...ith trainings meetings and other programs and a fine support community The purpose is to manufacture cost effective and best quality products which are simultaneously suitable for telecommunication st...

Страница 8: ...walls of buildings where a clear optical path exists between the two sites Next to the head the Outdoor Interconnection Unit provides fast and easy interconnection between the laser head and the cable...

Страница 9: ...The Pico Plus PoE systems should be considered as repeaters in the network So the installation distance between the head and the network device is 100m The distance on a back to back site is maximum 5...

Страница 10: ...part of the system you will receive E1 multiplexers These multiplexers provide fast and easy connection to the laser device The TC link speed is 2 048Mbps E1 Interface systems layout The PicoPlus E1 r...

Страница 11: ...aserBit PicoPlus Series 1 0 page 11 4 Product matrixes 4 1 Interface matrix In the spreadsheet below you can see the interface availability E1 E100TP PicoPlus 4 2 Power supply configuration E1 PicoPlu...

Страница 12: ...he Power supply unit and the bracket to the wall below you can see what is provided in the Pico Plus package ODIUs and ODIU accessories only in case of E1 systems 2ps of LB PICO Plus heads 2ps of LB O...

Страница 13: ...cases this effect can be avoided by careful selection of the mounting spot In order to comply with the requirements of the successful installation including the discussed four key factors and other c...

Страница 14: ...constructs Metal masts or Frames Hidden heat isolations like Styrofoam In cases where installations are listed under AVOID cannot be avoided than special mounting accessories to be designed and speci...

Страница 15: ...t is possible Examine both sides of the link at sunset and sunrise and find a position where the sun cannot get behind any of the heads Be aware that the path of the sun is changing throughout the yea...

Страница 16: ...ss II EN 60950 1 2001 electrical safety EN 55022 1998 Corr 2001 A1 2000 and EN 55024 1998 Dismounting the cover can cause fatal injury Manufactured by LaserBit Communications Corp 1037 Budapest Kunigu...

Страница 17: ...ll with a permanent marker Use your 10mm wall drill to drill all of the holes into the wall Clean the holes Place the wall plugs into the holes please note that some times you need to use hammer to pu...

Страница 18: ...l strength LED s Make sure that the Saturation indicator is OFF Adjust your attenuators if necessary to avoid saturation of the receivers Please note that at this short distance specially the longer d...

Страница 19: ...he bolts into the holes which is easily accessible for the installation and the two cuts Place up the washers and spring washers Fix the bolts with the nuts After you put up the washers and the nuts d...

Страница 20: ...l direction but be careful that the heads do not move out from its position Meanings of the LEDs Power The head is powered up FO Link Fibre optical link between the two heads TP Link Copper link betwe...

Страница 21: ...ht hand side and tighten it with the spanner and reach the maximum again We strongly suggest you to repeat the steps 2 3 times to make sure that the bolts are tight 3 In the meantime the remote end sh...

Страница 22: ...able This provides the power and the data for the LaserBit Pico Plus laser head The unit has connection for the management on the bottom of the Laser unit Please see the connection below This is the s...

Страница 23: ...range 8 5V Whi e 3 Green t GND 4 Blue RS485 5 Blue White RS485 6 Green 8 5VDC White 7 Brown 8 5VDC 8 Brown 30VDC 1 Orange hi RX RX W te 2 Orange Whi e 3 Green t 4 Blue TX 5 Blue White TX 6 Green White...

Страница 24: ...er two r the head On the secondary side the fuse ratings are T4A 250V F The outdoor interconnection unit ODIU provides the power supply and data connection The ODIU made from poly propylene enforced w...

Страница 25: ...Pull on the metal plate to the legs of the screws Fix the metal plate with four M5 nuts using the four washers and four spring washers like in the figure Then you can fix the whole construction to a w...

Страница 26: ...e head to the ODIU and the ODIU to the power supply Ensure that the cables are connected as it seen below For the power connection recommended to use three wired 0 75mm cables The order of the connect...

Страница 27: ...signals can be found on the blue and brown wires of the head power cable You have to connect these two wires into two pins of the four of the two green connectors These pins are connected to the pins...

Страница 28: ...ding loss of data lost profits lost savings lost business or other incidental or consequential or indirect damages arising out of the installation use maintenance performance failure or interruption o...

Страница 29: ...t The foregoing warranties and remedies are exclusive and are in lieu of all other warranties expressed or implied either in fact or by operation of law statutory or otherwise including warranties of...

Страница 30: ...10 Appendix A a Product registration form Please take your time to fill out Laserbit product registration form to ensure your warranty period begins otherwise Laserbit consider warranty beginning fro...

Страница 31: ...LaserBit PicoPlus Series 1 0 page 31 b Failure report form In case of failures please report it to us and fill out the failure report form forward to your distributor...

Страница 32: ...LaserBit PicoPlus Series 1 0 page 32 10 1 PICO PLUS Data Sheet...

Отзывы: