background image

L A S E R   T O O L S

Cam Belt Tensioner Gauge

5

1.

This is a precision measuring instrument. To ensure
accurate results it is essential that the operating
procedure is correctly followed.

2.

The instrument must only be used with the measuring
head with which it has been calibrated. When the unit is
supplied, the main unit and the measuring head will have
the same serial number, for example:

Main unit

H101000

Measuring head

H101000

3.

If the instrument is used with a different measuring head,
it must be re-calibrated before using.

4.

To avoid potential irreparable damage, never clamp the
measuring head onto a belt unless the head is plugged
in and the instrument is switched on. 

5.

The instrument warns of a head overload condition, but
is unable to if the head is unplugged or the instrument is
switched off.

6.

Never clamp the measuring head onto an inflexible
object such as a metal or wooden bar.

7.

Never drop the instrument or subject it to sharp impacts.

8.

Never allow the instrument or measuring head to hang
by the connecting cable.

1.

Before using the instrument for the first time, remove the
battery compartment cover, and fit four AA size 1.5V
alkaline batteries. Ensure that the batteries are inserted
correctly, as printed inside the battery compartment.

2.

Plug the DIN connector of the measuring head into the
DIN socket of the main unit.

3.

Switch on the instrument by pressing the

‘I’ 

key. The

three LED’s will flash for about two seconds whilst the
unit initialises. If the LED’s do not flash, then the batteries
may be flat or incorrectly fitted.

4.

The message 

‘LASER' 

will appear for one second.

5.

This is followed by the message 

‘DISPLAY CONTRAST’

then the prompt 

‘LIGHT / DARK / OK 

6.

If the display is too light or too dark, the contrast may be
adjusted by pressing and holding down the 

key to

darken it, or the     key to lighten it.

When the display contrast is OK, press the 

*

key. 

The display contrast is remembered when the instrument
is switched off, even if the batteries are removed. 

Precautions

Operation

>

>

Содержание 4212

Страница 1: ...4212...

Страница 2: ...Instructions Cam Belt Tensioner Gauge Measure the tension on most cam belts...

Страница 3: ...ay whilst adjusting the belt The selected tension limits measurement units and calibration parameters are stored in a non volatile memory and will be remembered even when the instrument is switched of...

Страница 4: ...functions The I key switches on the instrument During operation of the instrument it functions as an ENTER key The SET key switches the instrument from measurement mode to setting mode It also functio...

Страница 5: ...Never drop the instrument or subject it to sharp impacts 8 Never allow the instrument or measuring head to hang by the connecting cable 1 Before using the instrument for the rst time remove the batter...

Страница 6: ...KILOGRAMS FORCE SEEM LOWENER UNITS NEWTONS PEISELER UNITS POUNDS FORCE 12 When the required unit appears on the screen press the key to select them The rst time the instrument is used the default unit...

Страница 7: ...ll be displayed At this point the measuring head should not be clamped onto the belt nor have any load applied to it Ensure that the clamping knob is fully unscrewed 18 Press the key to zero the instr...

Страница 8: ...tension as described in Getting the best results 28 If it is required to change the measurement unit target tension or limits the instrument can be switched from measuring mode to set mode by pressing...

Страница 9: ...r out of limit indication When TURN BEEPER OFF is displayed pressing the key turns the beeper off Note The beeper always sounds to con rm a key press or a fault condition When TURN LEDS ON is displaye...

Страница 10: ...rs If the battery needs changing the red LED will ash and the display will show the message LOW BATTERY Note If the battery is completely drained the instrument will not operate at all The tension gau...

Страница 11: ...d Up to 36mm 0 750 0 to 77 0 to 170 0 to 12 0 0 to 53 0 to 14 5 0 to 114 750 850 10 or at least 1 sig digit 5 of full scale 16 Characters LCD 3 LEDs Piezoelectric sound 5 key tactile membrane 4 x 1 5v...

Отзывы: