LTI TruSense S300 Series Integration Manual 3nd Edition
Page 61
Copyright © [2016] Laser Technology, Inc. All Rights Reserved. Unauthorized duplication, in whole or in part, is strictly prohibited.
S300/S310 I/O Trigger Cable Wiring with Optional RS-232 for Ruggedized Enclosure Terminal
Block
Wiring with cable 7054674
Sensor Connection Table
PIN #
Wire Color
S330
1
Grey
SHTDWN
2
Black
GND
3
Brown
RS232 TX
4
Blue
RS232 RX
5
Red
+12-24 VDC
6
White
TRIG
RS-232
TX
TRIG
RS-232
Rx
GND (-)
SHTDWN
12-24VDC
(+)
Ruggedized Enclosure Terminal Block
RS-232
TX
TRIG
RS-232
Rx
GND (-)
SHTDWG
12-24VDC
(+)
Drawing 8: S300 / S310 I/O Trigger Ruggedized Enclosure Terminal Block
1 2 3 4 5 6
V
12-24VDC
Sensor
Power
Source
+
-
OEM Connector
Brown
Blue
White
Black
Red
Grey
1
RX 2
TX 3
4
GND 5
6
7
8
9
Cu
sto
me
r Wir
in
g
Se
n
so
r Wir
in
g
Grey
White
There are three option available for Pins 2 (See serial command
$TG)
IMPORTANT:
Only use one Optional wiring 1 or 3 below per
sensor.
1.
Trigger-In
(See $TG) Note: R1 is 1.2KOhm 5% - ¼ W
(Optional for 5VDC)
2.
Shutdown
Note: Power voltage 5VDC
3.
Trigger-Out
(See $TG) Note: Maximum drive is 5VDC at
40mA.