A = 600 cm2 convective air inlet
B = 600 cm2 discharge decompression hood
C = Ø 80 mm, N ° 2 independent hot air forced outlets, can be ducted
up to 5 meters (use phonically and thermally insulated pipes)
D = Ø 200 mm, minimum flue chimney diameter, recommended
height 5 linear straight lines (12 pascal)
E = Ø 100 mm, external air intake according to UNI10683 regulations
F = Inspection door to access all components (minimum 50 x 140 cm)
REQUIRED COVER TECHNICAL INSPECTION
IMPORTANT: On the side of the electrical
components in the coating must include a cover
technical inspection for routine maintenance with
opening large enough to access the components
(minimum size L 50 x H 140 cm).
12. THE CHIMNEY
WARNING: This appliance is NOT equipped with
smoke extractor (instead present exclusively in the
pellet working products). The chimney must therefore
have a NATURAL DRAFT of minimum 12 Pa, maximum
20 Pa whether used in wood or pellets: this is the
essential condition for safe use of the appliance.
IMPORTANT: Contact a qualified installer and have
the draft checked according to UNI 10389/2. The
Company declines all responsibility if the required draft
is not checked and certified.
The wall outlet is forbidden (in addition to the warranty
being waived, the fireplace would not work).
The chimney must comply with the requirements of UNI
10683, which is currently in force in Italy. For all other
countries, national regulations must be respected.
The device can only be connected to a single flue dedicated to it and
it must be done in order to allow the recovery of ash and must be
viewable, inspectable and cleanable with brushes. All chimneys and
pipes suitable for the connection must be fitted with a regular marking
plate indicating the characteristics as indicated in the Italian standard
UNI 10683.
Smoke evacuation system components designation example:
EN 1443
1
T400
2
N1
3
D
4
2
5
G50
6
1
Number of corresponding legislation
2
Temperature class (UNI EN 1443)
3
Pressure class: N or P or H (UNI EN 1443)
4
Condensation resistance class (UNI EN 1443)
5
Corrosion resistance class (UNI EN 1443)
6
Soot fire resistance class: G or O followed by distance from
flammable materials.
Temperature class (es: T400 minimum, T450-T600
suggested)
The chimney temperature class (as per UNI EN 1443) should not be
lower than the maximum exhaust gasses temperature declared by the
stove manufacturer.
For all appliances as per UNI EN 14785 (appliances for home heating
burning wooden pellet as fuel – requirements and testing procedure)
temperature class lower than T400 are not allowed. In any case
always check the stove data sheet for technical details but
temperature Txxx should be at least 50 °C higher than the maximum
smoke temperature.
Pressure class (smoke tightness) N
Since all chimneys must work in depression, the pressure class will be
N = negative
By the end a chimney showing this tag is perfect to fit a pellet stove:
T450N1D2GXX
Soot fire resistance class G
All smokestacks connect to appliances burning solid fuel must be soot
fire resistant; the designation letter will therefore be G followed by the
distance in millimeters (XX) (as per UNI EN 1443) from flammable
materials. The chimney has to be built as UNI 10683 regulation, for
all other countries, accordance with local and national regulations in
force.
WARNING The chimney must be hermetically
connected to the appliance but its weight should not be
burdened with it.
13. CROSSING ROOFS/CEILING INFLAMMABLES
Be very careful when getting through walls, ceilings or roofs made of
flammable materials. The high smoke temperatures can start a fire.
Do always respect the safety distances as per UNI 10683 Italian
regulation. For all other countries, respect all local and national
regulations in force.
A = isolated double-walled tube
B = flammable material
X = The distance indicated on the chimney plate GXXX in mm
14. EXTERNAL AIR INLET CONNECTION
The outside air intake must have a minimum Ø of 100 mm.
The appliance can be connected directly to the air inlet with a tube. Ø
80 mm only in case of exclusive use of wood (no pellets). In this case
the maximum length of the connection can be a tube of 1 meter and
maximum a 90 ° curve.
If using pellets or pellets / wood combined leave the air intake free on
the back of the chimney without connecting it directly.
However, UNI 10683 or local and national regulations must be
respected for the size and presence of external air intake.
Содержание Pellicano M14
Страница 14: ...L ARTISTICO SRL IT 14 Cod 40014 Rev 04 08 06 2018 32 SCHEMA ELETTRICO ...
Страница 16: ...L ARTISTICO SRL EN 16 Cod 40014 Rev 04 08 06 2018 ...
Страница 29: ...L ARTISTICO SRL EN 29 Cod 40014 Rev 04 08 06 2018 32 ELECTRICAL DIAGRAM ...
Страница 31: ...L ARTISTICO SRL 31 Cod 40115 Rev 04 08 06 2018 ...