background image

IND-CDL-SQ-10-FUVC-MP-1L-V1

Larson Electronics, LLC

 

  Phone: (800) 369-6671 

 Fax: (903) 498-3364 

 www.larsonelectronics.com 

1

 of 

1

5

Far-UV Recessed 10" Square Light

(1) 10W Microplasma Board, 222 nm UVC Sanitation - Recessed Mount

Instruction Manual

Thank you for your purchase of the Larson Electronics

 

IND-CDL-SQ-10-FUVC-MP-1L-V1

.

EPA Reg. No 98409-1

EPA Est. No. 98409-TX-1

WARNING: 

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. 

CRITICAL SAFETY INSTRUCTIONS: 

INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY

RELEVANT LOCAL BUILDING CODES.

RISK OF FIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF 

FIXTURE'S

 ELECTRICAL

SYSTEMS. IF NOT QUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.

BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.

MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE

 FIXTURE'S

 RATED VOLTAGE.

TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP

OBJECTS. SUITABLE FOR DAMP LOCATIONS.

IMPORTANT

 

READ  CAREFULLY  BEFORE  INSTALLING  THIS  FIXTURE.  SAVE  THESE  INSTRUCTIONS  FOR  FUTURE 

MUST

REFERENCE. 

THE 

IND-CDL-SQ-10-FUVC-MP-1L-V1

 

 

BE

WIRED 

IN  ACCORDANCE  WITH  NATIONAL  ELECTRICAL  CODE  AND  ALL  APPLICABLE  LOCAL 

CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.  

WE  STRONGLY  ENCOURAGE  ONLY  A  LICENSED  ELECTRICIAN  INSTALL,  OPERATE  AND  MAINTAIN  THIS 

PRODUCT.  IF  YOU  ARE  NOT  QUALIFIED  OR  UNFAMILIAR  WITH  ANY  ASPECT  OF  THIS  INSTRUCTION 

SHEET, CONSULT AN ELECTRICIAN. THERE ARE NO SERVICEABLE PARTS INSIDE. 

WARNING:

 

MAKE SURE POWER IS TURNED 

OFF

 BEFORE STARTING THE 

INSTALLATION OR PERFORMING ANY MAINTENANCE.

 

 

RISK OF FIRE/ELECTRIC SHOCK –

 

DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING.

 

RISK OF PERSONAL INJURY –

 

FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROPERLY. 

RISK OF BURN –

 

ALLOW FIXTURE TO COOL BEFORE SERVICING. 

WARNING: 

USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE.

  THIS  LINE

CORD IS INTENDED TO ALLOW OPERATORS TO EXTEND POWER TO EQUIPMENT WHEN STATIONARY OUTLETS ARE NOT 

READILY AVAILABLE.

 

IMPROPER USE OF THIS CORD, PLUG, AND RECEPTACLE CAN LEAD TO SERIOUS INJURIES OR DEATH TO 

PERSONNEL. 

PERIODIC INSPECTION OF THE CORD IS NECESSARY.

 

THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY ARE FOUND, 

THE CORD MUST BE REPLACED BEFORE RESUMING USE.   

UV Warning 

WARNING: 

ULTRAVIOLET LIGHT IS HARMFUL TO EYES AND SKIN. DO NOT STARE DIRECTLY INTO THE 

ULTRAVIOLET BEAM WITHOUT WEARING PROTECTIVE GEAR TO PROTECT EYES FROM LONG TERM DAMAGE. 

UNPLUG LAMP BEFORE SERVICING. 

The Larson Electronics IND-CDL-SQ-10-FUVC-MP-1L-V1 Far-UV Recessed Square Light disinfects 99% of 

viruses, bacteria, mold and spores from ceilings in occupied areas. This eye and skin safe disinfection unit uses 

one 10-watt microplasma board that emits far-UV 222 nm germicidal light. Featuring an expected lifespan of 6,000+ 

hours, the unit is compatible with 120-277V AC, 50/60Hz.

Содержание IND-CDL-SQ-10-FUVC-MP-1L-V1

Страница 1: ...ND MAINTAIN THIS PRODUCT IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION SHEET CONSULT AN ELECTRICIAN THERE ARE NO SERVICEABLE PARTS INSIDE WARNING MAKE SURE POWER IS TURNED OFF BEFORE STARTING THE INSTALLATION OR PERFORMING ANY MAINTENANCE RISK OF FIRE ELECTRIC SHOCK DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING RISK OF PERSONAL INJURY FIXTURE MAY BECOME UN...

Страница 2: ...of the fixture will cover the hole once mounted 1 Carefully unpack and unwrap fixture 2 Turn OFF power at switch and fusebox or circuit breaker 3 Remove existing trim installed in recessed housing if necessary 4 Install medium base adapter into socket 5 Connect the two terminals together 6 Insert torsion springs into fixture housing brackets 7 When installing trim into recessed housing the torsion...

Страница 3: ...ed modification may impair the function and or safety of this device and could affect the life of the equipment Always check for damaged or worn out parts before using the device Store it in a secure place out of the reach of children when not in use Inspect for good working condition prior to storage and before re use REPLACEMENT PARTS The IND CDL SQ 10 FUVC MP 1L V1 is designed to provide years ...

Страница 4: ...Independent studies have shown that Far UV C light is less likely to be harmful to eyes and skin As of 2020 the FDA has not approved Far UV C light sources for use in occupied areas in medical facilities This is something to be voted on in the near future for medical applications At this time the FDA has not ruled on the safety Independent studies have been done Please see the following whitepaper...

Страница 5: ...Far UV 222 nm vs 254 nm Safety and Germicidal Effectiveness ...

Страница 6: ...1 How Does UV C Light Sanitation Work 4 0 Far UV C 222 nm 4 1 UV 222 nm Wavelength Properties 4 2 Safety Considerations 4 3 Germicidal Effectiveness 5 0 UV C 254 nm 5 1 UV 254 nm Wavelength Properties 5 2 Safety Considerations 5 3 Germicidal Effectiveness 6 0 Conclusion 7 0 References ...

Страница 7: ...althcare centers laboratories food processing wastewater facilities HVAC system management and more At 2018 the UV disinfection equipment market was valued at 1 1 billion by Allied Market Research This industry is forecasted to reach 3 4 billion by 2026 or at a compound annual rate of 15 percent from 2019 to 2026 UV light contains several unique properties and characteristics which can be used to ...

Страница 8: ...e mechanism when deactivating bacteria and viruses other factors must be considered when choosing between far UV 222 nm and conventional 254 nm lamps Such factors include the area of deployment occupied or empty distance of target surface or area access to UV lamp technology to date 222 nm excimer lamps are not readily available in mainstream markets and preferred method of disposal traditional me...

Страница 9: ... Such objectives prevent the microbe from spreading and decreases the rate of infection for harmful viruses or bacteria Higher UV doses must be applied to bacteria that is capable of actively repairing thymine dimers Far UV 222 nm and conventional 254 nm UV light utilizes the same mechanism as described above to eliminate microorganisms on surfaces and in the air Both types of UV bands are capable...

Страница 10: ...e light beam distribution and intensity With a compact footprint smaller disinfection lights can be used to eliminate microbes The units require support from a driver that protects the device from abnormal power conditions and ensures power stability Unlike traditional 254 nm UV sanitation lights excimer lights do not require extensive safety gear during use Furthermore the lamps can be secured cl...

Страница 11: ...against irritants such as debris and bacteria and plays a primary role in light absorption Damage to the cornea often results in vision impairment or loss During the study researchers exposed rats to 222 nm and 254 nm lights at 30 150 and 600 mJ cm2 intensities The animals exposed to far UV 222 nm did not display corneal damage Moreover cyclobutane pyrimidine dimer positive cells were not present ...

Страница 12: ...rds A 2020 study10 showed that far UV 222 nm lamps can inactivate Alicyclobacillus acidoterrestris spores which are known to have high thermal resistance In food processing facilities handling juices the microorganisms also thrive in extreme conditions and can germinate at low pH levels Scientists were able to achieve complete inactivation by 5 logs at a concentrated dose of 2 011 mJ cm2 Compared ...

Страница 13: ...g at UV lamps does not cause a natural squinting reaction In some cases the negative effects of UV exposure are delayed by more than six hours As a safety precaution when sanitizing rooms humans should not be present in the area during the process Operators may setup temporary signs around the space to ensure people are aware of ongoing sanitation and avoid exposure Exposure to chemicals such as m...

Страница 14: ...fect on the eggs compared to the adult mites Based on the results of the study the scientists cited UV 254 nm light to be effective in disrupting the lifecycle of mites at the embryonic stage to reduce the proliferation of allergens 6 0 Conclusion Both far UV 222 nm and conventional 254 nm wavelengths are effective in eliminating viruses bacteria spores and other disease causing microbes As these ...

Страница 15: ...cidal Efficacy and Mammalian Skin Safety of 222 nm UV Light 2017 https www ncbi nlm nih gov pmc articles PMC5552051 7 Evaluation of Acute Corneal Damage Induced by 222 nm and 254 nm Ultraviolet Light in Sprague Dawley Rats 2019 https pubmed ncbi nlm nih gov 30947566 8 Far UVC light A new tool to control the spread of airborne mediated microbial diseases 2018 https www nature com articles s41598 01...

Отзывы: