Warning: 

Check product label for correct input voltage!

 

Attach supply line wires to the appropriate light fixture wires as shown in the 

diagram 

 

Secure  each  pair  of  wires  according  to  the  diagram.  Utilize  a  junction  box  or 

similar  device  and  take  precautionary  steps  for  weatherproofing  all 

connections  if  installed  in  a  location  where  water  may  come  in  contact  with  the  unit. 

Ensure the unit is properly grounded and that wiring is done according to all local and 

national electrical/building codes. 

MOUNTING

 

Standard pigtail(flying leads) wiring 

We strongly encourage a licensed electrician install this product

, in all locations especially in outdoor areas 

where weatherproofing may be required. Universal voltage driver permits operation at 1

2

0V  -  277V AC, 50 or 60Hz. 

WIRING 

NOTE: User must cutout a 9.4" x 9.4" hole for the 

fixture to be inserted into the ceiling. The remaining 

parts of the fixture will cover the hole once mounted.

1.

Carefully unpack and unwrap fixture.

2.

Turn OFF power at switch and fusebox or circuit 

breaker.

3.

Remove existing trim installed in recessed 

housing (if necessary).

4.

Install medium base adapter into socket.

5.

Connect the two terminals together.

6.

Insert torsion springs into fixture housing 

brackets.

7.

When installing trim into recessed housing, the 
torsion spring must be moved. Make sure 
mounting bracket is

 

installed with the label faced 

downwards.

8.

Gently push up trim and torsion springs so they 

begin to expand and lift trim in place.

The far-UV sanitation light is compatible with recessed mounting on ceilings. This unit can be secured on existing 10" square lights. When 

mounted at a height of 8-10 feet, the germicidal UV light covers up to 50-100 square feet of targeted surface. Residual sanitation occurs up 

to 300 square feet.

WARNING:

This unit 

DOES NOT

 have a glass lens. Users should avoid touching the exposed board at all costs. 

Touching the board 

can cause an electric shock.

 

Fixture needs to be installed in a location where contact to the board cannot be made.

INSTALLATION

Figure:1

4x Retaining Spring Clips

FUVC Light Fixture

Ceilling

Figure:2

Содержание IND-CDL-SQ-10-FUVC-MP-1L-V1

Страница 1: ...ND MAINTAIN THIS PRODUCT IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION SHEET CONSULT AN ELECTRICIAN THERE ARE NO SERVICEABLE PARTS INSIDE WARNING MAKE SURE POWER IS TURNED OFF BEFORE STARTING THE INSTALLATION OR PERFORMING ANY MAINTENANCE RISK OF FIRE ELECTRIC SHOCK DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING RISK OF PERSONAL INJURY FIXTURE MAY BECOME UN...

Страница 2: ...of the fixture will cover the hole once mounted 1 Carefully unpack and unwrap fixture 2 Turn OFF power at switch and fusebox or circuit breaker 3 Remove existing trim installed in recessed housing if necessary 4 Install medium base adapter into socket 5 Connect the two terminals together 6 Insert torsion springs into fixture housing brackets 7 When installing trim into recessed housing the torsion...

Страница 3: ...ed modification may impair the function and or safety of this device and could affect the life of the equipment Always check for damaged or worn out parts before using the device Store it in a secure place out of the reach of children when not in use Inspect for good working condition prior to storage and before re use REPLACEMENT PARTS The IND CDL SQ 10 FUVC MP 1L V1 is designed to provide years ...

Страница 4: ...Independent studies have shown that Far UV C light is less likely to be harmful to eyes and skin As of 2020 the FDA has not approved Far UV C light sources for use in occupied areas in medical facilities This is something to be voted on in the near future for medical applications At this time the FDA has not ruled on the safety Independent studies have been done Please see the following whitepaper...

Страница 5: ...Far UV 222 nm vs 254 nm Safety and Germicidal Effectiveness ...

Страница 6: ...1 How Does UV C Light Sanitation Work 4 0 Far UV C 222 nm 4 1 UV 222 nm Wavelength Properties 4 2 Safety Considerations 4 3 Germicidal Effectiveness 5 0 UV C 254 nm 5 1 UV 254 nm Wavelength Properties 5 2 Safety Considerations 5 3 Germicidal Effectiveness 6 0 Conclusion 7 0 References ...

Страница 7: ...althcare centers laboratories food processing wastewater facilities HVAC system management and more At 2018 the UV disinfection equipment market was valued at 1 1 billion by Allied Market Research This industry is forecasted to reach 3 4 billion by 2026 or at a compound annual rate of 15 percent from 2019 to 2026 UV light contains several unique properties and characteristics which can be used to ...

Страница 8: ...e mechanism when deactivating bacteria and viruses other factors must be considered when choosing between far UV 222 nm and conventional 254 nm lamps Such factors include the area of deployment occupied or empty distance of target surface or area access to UV lamp technology to date 222 nm excimer lamps are not readily available in mainstream markets and preferred method of disposal traditional me...

Страница 9: ... Such objectives prevent the microbe from spreading and decreases the rate of infection for harmful viruses or bacteria Higher UV doses must be applied to bacteria that is capable of actively repairing thymine dimers Far UV 222 nm and conventional 254 nm UV light utilizes the same mechanism as described above to eliminate microorganisms on surfaces and in the air Both types of UV bands are capable...

Страница 10: ...e light beam distribution and intensity With a compact footprint smaller disinfection lights can be used to eliminate microbes The units require support from a driver that protects the device from abnormal power conditions and ensures power stability Unlike traditional 254 nm UV sanitation lights excimer lights do not require extensive safety gear during use Furthermore the lamps can be secured cl...

Страница 11: ...against irritants such as debris and bacteria and plays a primary role in light absorption Damage to the cornea often results in vision impairment or loss During the study researchers exposed rats to 222 nm and 254 nm lights at 30 150 and 600 mJ cm2 intensities The animals exposed to far UV 222 nm did not display corneal damage Moreover cyclobutane pyrimidine dimer positive cells were not present ...

Страница 12: ...rds A 2020 study10 showed that far UV 222 nm lamps can inactivate Alicyclobacillus acidoterrestris spores which are known to have high thermal resistance In food processing facilities handling juices the microorganisms also thrive in extreme conditions and can germinate at low pH levels Scientists were able to achieve complete inactivation by 5 logs at a concentrated dose of 2 011 mJ cm2 Compared ...

Страница 13: ...g at UV lamps does not cause a natural squinting reaction In some cases the negative effects of UV exposure are delayed by more than six hours As a safety precaution when sanitizing rooms humans should not be present in the area during the process Operators may setup temporary signs around the space to ensure people are aware of ongoing sanitation and avoid exposure Exposure to chemicals such as m...

Страница 14: ...fect on the eggs compared to the adult mites Based on the results of the study the scientists cited UV 254 nm light to be effective in disrupting the lifecycle of mites at the embryonic stage to reduce the proliferation of allergens 6 0 Conclusion Both far UV 222 nm and conventional 254 nm wavelengths are effective in eliminating viruses bacteria spores and other disease causing microbes As these ...

Страница 15: ...cidal Efficacy and Mammalian Skin Safety of 222 nm UV Light 2017 https www ncbi nlm nih gov pmc articles PMC5552051 7 Evaluation of Acute Corneal Damage Induced by 222 nm and 254 nm Ultraviolet Light in Sprague Dawley Rats 2019 https pubmed ncbi nlm nih gov 30947566 8 Far UVC light A new tool to control the spread of airborne mediated microbial diseases 2018 https www nature com articles s41598 01...

Отзывы: