IND-CDL-SQ-10-FUVC-MP-1L-V1
Larson Electronics, LLC
Phone: (800) 369-6671
Fax: (903) 498-3364
www.larsonelectronics.com
2
of
1
5
Warning:
Check product label for correct input voltage!
Attach supply line wires to the appropriate light fixture wires as shown in the
diagram
Secure each pair of wires according to the diagram. Utilize a junction box or
similar device and take precautionary steps for weatherproofing all
connections if installed in a location where water may come in contact with the unit.
Ensure the unit is properly grounded and that wiring is done according to all local and
national electrical/building codes.
MOUNTING
Standard pigtail(flying leads) wiring
We strongly encourage a licensed electrician install this product
, in all locations especially in outdoor areas
where weatherproofing may be required. Universal voltage driver permits operation at 1
2
0V - 277V AC, 50 or 60Hz.
WIRING
NOTE: User must cutout a 9.4" x 9.4" hole for the
fixture to be inserted into the ceiling. The remaining
parts of the fixture will cover the hole once mounted.
1.
Carefully unpack and unwrap fixture.
2.
Turn OFF power at switch and fusebox or circuit
breaker.
3.
Remove existing trim installed in recessed
housing (if necessary).
4.
Install medium base adapter into socket.
5.
Connect the two terminals together.
6.
Insert torsion springs into fixture housing
brackets.
7.
When installing trim into recessed housing, the
torsion spring must be moved. Make sure
mounting bracket is
installed with the label faced
downwards.
8.
Gently push up trim and torsion springs so they
begin to expand and lift trim in place.
The far-UV sanitation light is compatible with recessed mounting on ceilings. This unit can be secured on existing 10" square lights. When
mounted at a height of 8-10 feet, the germicidal UV light covers up to 50-100 square feet of targeted surface. Residual sanitation occurs up
to 300 square feet.
WARNING:
This unit
DOES NOT
have a glass lens. Users should avoid touching the exposed board at all costs.
Touching the board
can cause an electric shock.
Fixture needs to be installed in a location where contact to the board cannot be made.
INSTALLATION
Figure:1
4x Retaining Spring Clips
FUVC Light Fixture
Ceilling
Figure:2