MAINTENANCE

Caution:

 To avoid personal injury, disconnect power to the light and allow the unit to cool down before performing 

maintenance. 
Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine checks to be made on 

a yearly basis. Frequency of use and environment should determine this.  It is recommended to follow an Electrical 

Preventive Maintenance Program as described in NFPA 70B: Recommended practice for Electrical Equipment. 
The lens should be cleaned periodically as needed to ensure continued photometric performance. Clean the lens with a 

damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid cleaner.
Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.

BULB CHANGE

The lens is held on by 3 removable clips and a hinge on one side that allows it to swing open. To change the bulb, first 

remove the 3 clips by pulling them out away from the fixture from the back side of the fixture. This will free the lens to be 

able to swing open via the hinge. There is a rubber gasket around the edge of the lens, so some light prying may be 

necessary. Take care not to damage this gasket when opening. Remove the bulb by turning counter-clockwise until it is 

free of the socket, and replace with a new bulb by turning it into the socket clockwise until firmly seated. Close the lens, 

pressing evenly around the edge to seat the rubber gasket back in place, and replace the removable clips to hold in 

place. 

USE AND CARE

Unauthorized modification may impair the function and/or safety of this device and could affect the life of the equipment. 

Always check for damaged or worn out parts before using the device. Store it in a secure place out of the reach of 

children when not in use. Inspect for good working condition prior to storage and before re-use.

 

 

REPLACEMENT PARTS

The 

HID-22-SL

 is designed to provide years of reliable performance. Should the need for replacement parts arise, 

please contact Larson Electronics. 

THESE INSTRUCTIONS MAY  NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. 

SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT 

[email protected]

 OR BY PHONE AT 

1-877-348-9680

 FOR FURTHER ASSISTANCE. 

PLEASE VISIT LARSONELECTRONICS.COM FOR 

WARRANTY

 AND 

RETURN

 INFORMATION.

Larson Electronics, LLC

 

 Phone: (8

77

) 3

48

-

9680

 

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

2

 of 

2

 

Отзывы: