PneUmAtic motor VerSion
initiAl SetUP
1. Secure a compressed air source capable of supplying a minimum 80 - 100 psi and 70 cfm flow rate. A minimum
hose I.D. of a 1/2” is required to connect to a 1/2” Industrial Interchange style male plug.
2. The air motor has no moving parts and requires no service if the air source is clean air, free of oil and water. An
“on-oFF” valve is provided to regulate flow to the air motor.
Warning:
operating this air motor above 100 psi may cause implosion of the metal can.
Do not tamper with the relief valve supplied internally on the air motor.
Filter maintenance
caution:
Always unplug vacuum from power source before changing filters.
2-Ply Disposable Paper Filter Bag
When the 2-ply disposable paper bag is full, it must be replaced. Excessive overfilling of this bag makes if difficult
to remove from the vacuum tank and can result in breakage and/or spills.
2-Ply intermediate Filter
The 2-ply intermediate filter should be replaced with every fifth (5) change of the paper bag, or whenever there is
damage or visible collection of debris on the outside of the filter.
HePa Filter
Replace the HEPA filter when loss of suction continues to occur after you have checked for an obstruction in the
hose or wand, installed a new 2-ply-disposable paper filter bag, and installed 2-ply intermediate filter.
caution:
Hazardous materials must be disposed of properly. nEVER throw contaminated debris in your standard
trash receptacle. Place debris in a 6 mil poly bag or container marked with HAZARDoUS MATERIALS warning and
dispose of in accordance with your local hazardous waste regulations.
eQUiPment mAintenAnce
Contact distributor or manufacturer to receive written authorization for return of vacuum. Transportation
charges to the service location must be paid by the purchaser.
Any w
arranty is void if electrical components
are ser
-
viced by non-factory service personnel. The use of non-certified parts can result in possible safety
hazards and void UL certifications.
6