background image

 

 

 

EPLC2-QP-1X150LED-100 

Larson Electronics, LLC

 

          Phone: (800) 369-6671   

 Fax: (903) 498-3364  

     www.larsonelectronics.com 

3

 of 

4

 

WIRING 

(see attached wiring diagram)

 

This unit comes preconfigured with selected cord cap, and beam spread. Once deployed, plug cord 
cap into compatible receptacle with 

Voltage: 100-277 Volts AC, 50/60Hz

 

MAINTENANCE

 

Caution: 

To avoid personal injury, disconnect power to the light and allow the unit to cool 

down before performing maintenance. 

 

Warning: 

No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens 

will void the warranty. 

 

1. 

Perform visual, mechanical and electrical inspections on a regular basis. We recommend 
routine checks to be made on a yearly basis. Frequency of use and environment should 
determine this.  It is recommended to follow an Electrical Preventive Maintenance Program 
as described in NFPA 70B: Recommended practice for Electrical Equipment. 

2. 

The lens should be cleaned periodically as needed to ensure continued photometric 
performance. Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use 
mild soap or a liquid cleaner. 

3. 

Inspect the cooking fins on the luminaire to ensure that they are free of any obstructions 
or contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if 
needed. 

4. 

Do not operate if the lens is cracked or damaged. All fasteners should be properly seated. 

 

 

WARNING:

 CHECK NAMEPLATE 

FOR PROPER VOLTAGE. DAMAGE 
FROM IMPROPER VOLTAGE WILL 
VOID WARRANTY. 

Отзывы: