background image

EPL-20W-HID-X12V-347V-GR50

Larson Electronics, LLC

 

 Phone: (800) 369-6671 

Fax: (903) 498-3364 

www.larsonelectronics.com 

9

 of 

9

 

SPRING MOTOR REPLACEMENT 

1.

CAUTION: 

Do not open the spring motor or personal injury may result.

2.

Due to spool cable being sealed in the shaft, spring motors can only be factory rebuilt and replaced.

TROUBLESHOOTING 

PROBLEM

 

POSSIBLE CAUSE

 

SOLUTION

 

Reel will not retract cable 
but has some tension 

1.

Improper pretension

2.

Incorrect reel for
application (lift vs.
stretch)

3.

Cable guide adjustment

1.

See section “Spring Tension
Adjustment”

2.

Quantify application vs. reel selection

3.

Check guide alignment

Reel does not have any 
spring tension 

1.

Broken spring. Quantify
application to prevent
recurrence

1.

Factory rebuild

Ratchet will not activate 

1.

Broken ratchet pawl
spring

2.

Lock-out option arm
deactivated

1.

Replace ratchet pawl spring

2.

Activate lock-out arm

Ratchet will not 
deactivate 

1.

Over-extension of reel

1.

Manually rotate reel spool to deactivate
ratchet. Do not over-extend. (Guide adjustment may
prevent lock –up when over-extended

Cable wraps improperly 
(uneven wrapping, wraps 
above or jumps flange) 

1.

Reel mounting no level

2.

Cable retraction rate too
high

3.

Cable guide out of

adjustment

1.

Mount reel on level surface

2.

Maintain steady retraction rate

3.

Properly adjust cable guide

Cable twisting and 
knotting 

1.

Improperly installed cable

2.

Cable rubbing on or
bending around fixed
object

3.

Excessive spring tension

4.

Inadequate anchoring of
cable

1.

See section “Cable Installation”

2.

Check roller guide for function and cable payout
path

3.

Quantify application vs. reel selection Also check
pretension

4.

Adjust anchoring method i.e. and strain
relief

Open or intermittent 
circuit 

1.

Inadequate connection

2.

Loss of brush contact to
slip ring

3.

Cable defective

1.

Check all termination points

2.

Check brush wear, spring tension & alignment

3.

Perform continuity check on cable
termination points

Circuit trips and/or pitted 
burned rings or brushes 

1.

Inadequate amp rating of
reel selection

1.

Quantify application requirements vs.
reel and cable rating

Circuit arcing 

1.

Amp or voltage above
rating of reel

2.

Excessive carbon
dust accumulation

3.

Loss of brush to ring
contact

1.

Quantify application requirements vs. reel and cable
rating

2.

Clean dust from inside slip ring

3.

Replace brush and/or brush spring

THESE INSTRUCTIONS MAY  NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. SHOULD FURTHER 
INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT 

[email protected]

 OR BY PHONE 

AT 1-800-369-6671 FOR FURTHER ASSISTANCE. 

PLEASE VISIT LARSONELECTRONICS.COM FOR 

WARRANTY

 AND 

RETURN

 INFORMATION. 

Содержание EPL-20W-HID-X12V-347V-GR50

Страница 1: ...HESE INSTRUCTIONS FOR FUTURE REFERENCE THE EPL 20W HID X12V 347V GR50 MUST BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES PROPER GROUNDING IS REQUIRED FOR SAFETY W...

Страница 2: ...CESSARY THE CORD MUST BE ROUTINELY CHECKED FOR CUTS BREAKS OR ANY SEVERE ABRASIONS AND IF ANY ARE FOUND THE CORD MUST BE REPLACED BEFORE RESUMING USE OF THE UNIT ELECTRICAL POWER SUPPLY MUST BE OFF BE...

Страница 3: ...be required Universal voltage driver permits operation at 347V AC stepped down to 12V DC Warning Check product label for correct input voltage Attach supply line wires to the appropriate light fixtur...

Страница 4: ...the light without worry of damage or cool down It is suggested not to flash the light as this will shorten run time and lamp life INSTALLATION Electrical wiring on the reel must be done by a qualified...

Страница 5: ...y in the event of mounting failure WARNING Modifications of this equipment may cause excessive wear and will void the warranty Contact the manufacturer regarding changes or modifications of equipment...

Страница 6: ...eel cable more evenly 2 The cable should not pile against either end of the spool during winding as this will tend to inhibit level winding of the cable 3 The guide should be secured at the best of tw...

Страница 7: ...the drum and cable together in the direction of pay out in order to pre tension the spring The number of pre tension turns is determined by cable size and footage Usually four to sixteen turns is suff...

Страница 8: ...proper seating and all are in good condition with no marks or dents Replace all seals as necessary Lubricate with silicon lubricant or low mineral petroleum jelly A discoloration of the lamp reflecto...

Страница 9: ...retraction rate 3 Properly adjust cable guide Cable twisting and knotting 1 Improperly installed cable 2 Cable rubbing on or bending around fixed object 3 Excessive spring tension 4 Inadequate anchor...

Отзывы: