background image

EPL-20W-HID-X12V-347V-GR50

Larson Electronics, LLC

 

 Phone: (800) 369-6671 

Fax: (903) 498-3364 

www.larsonelectronics.com 

7

 of 

9

 

CABLE INSTALLATION 

Cable is factory installed and sealed. Consult factory for changes. 

SPRING TENSION ADJUSTMENT 

WARNING: 

Do not allow cable to retract without restraining the retraction speed. Walk the cable back to the reel during 

the spring tension adjusting process. Always maintain two full cable wraps on drum at maximum cable extension, size 
cable accordingly. 

1.

The EXPCRL reels come with pre-tension from the factory. Some adjustments may be required to meet
specific application requirements.

2.

To assure that the cable will retract properly and operate under the correct tension for intended

application; the reel should be tested. Securely mount reel before testing with cable installed on drum and end
of spool cable not connected, proceed with the next steps.

3.

Pull the cable out to the intended travel distance and allow it to rewind. This procedure should

be repeated five (5) to ten (10) times in order to set the spring. Walk the cable back to the reel during the
spring tension adjusting process.

Rotate Spool while holding Cable to Test the Spring Tension 

4.

With all the cable wound on the reel, grasp the end of the cable and
rotate the drum and cable together in the direction of pay out in
order to pre-tension the spring. The number of pre- tension turns is
determined by cable size and footage. Usually, four to sixteen turns
is sufficient, but additional turns may be used if testing indicates that
the cable will not fully retract as desired with just four turns.

Adding Spring Tension 

5.

Feed the end of the cable through the cable guide and pull the cable

out the required length. 

6.

Repeat steps 3 to 5, if necessary, to add tension. To decrease

tension, rotate drum and cable counter-clockwise. 

POWER CONNECTIONS 

1.

Provide power source with over-current protection to prevent overheating of the reel and cable.

2.

Reels are supplied with cord to ballast box. Those cords are the same cable as is supplied on the spool.
They are factory sealed with explosion proof potting compound and supplied with a watertight strain relief. If
a conduit connection is required, the strain relief must be removed and conduit connections made.

OPERATION 

1.

Do not exceed the voltage or amperage for the cable. Overheating, fire, damage to equipment or personal
injury could result.

2.

Do not allow cable to retract without restraining the retraction speed.

3.

Operate the reel within the cable size and length and spring tensioning limits for which it was intended.

4.

Keep two wraps of cable on the reel at maximum extension to avoid excessive tension on the cable and to
prevent pullout of cable from entrance watertight.

Содержание EPL-20W-HID-X12V-347V-GR50

Страница 1: ...HESE INSTRUCTIONS FOR FUTURE REFERENCE THE EPL 20W HID X12V 347V GR50 MUST BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES PROPER GROUNDING IS REQUIRED FOR SAFETY W...

Страница 2: ...CESSARY THE CORD MUST BE ROUTINELY CHECKED FOR CUTS BREAKS OR ANY SEVERE ABRASIONS AND IF ANY ARE FOUND THE CORD MUST BE REPLACED BEFORE RESUMING USE OF THE UNIT ELECTRICAL POWER SUPPLY MUST BE OFF BE...

Страница 3: ...be required Universal voltage driver permits operation at 347V AC stepped down to 12V DC Warning Check product label for correct input voltage Attach supply line wires to the appropriate light fixtur...

Страница 4: ...the light without worry of damage or cool down It is suggested not to flash the light as this will shorten run time and lamp life INSTALLATION Electrical wiring on the reel must be done by a qualified...

Страница 5: ...y in the event of mounting failure WARNING Modifications of this equipment may cause excessive wear and will void the warranty Contact the manufacturer regarding changes or modifications of equipment...

Страница 6: ...eel cable more evenly 2 The cable should not pile against either end of the spool during winding as this will tend to inhibit level winding of the cable 3 The guide should be secured at the best of tw...

Страница 7: ...the drum and cable together in the direction of pay out in order to pre tension the spring The number of pre tension turns is determined by cable size and footage Usually four to sixteen turns is suff...

Страница 8: ...proper seating and all are in good condition with no marks or dents Replace all seals as necessary Lubricate with silicon lubricant or low mineral petroleum jelly A discoloration of the lamp reflecto...

Страница 9: ...retraction rate 3 Properly adjust cable guide Cable twisting and knotting 1 Improperly installed cable 2 Cable rubbing on or bending around fixed object 3 Excessive spring tension 4 Inadequate anchor...

Отзывы: