EPL-20W-HID-X12V-347V-GR50

Larson Electronics, LLC

 

 Phone: (800) 369-6671 

Fax: (903) 498-3364 

www.larsonelectronics.com 

2

 of 

9

 

WARNING 

TO AVOID THE RISK OF FIRE, EXPLOSION OR ELECTRIC SHOCK, THIS PRODUCT SHOULD BE INSTALLED, 

INSPECTED AND MAINTAINED BY A QUALIFIED ELECTRICIAN ONLY, IN ACCORDANCE WITH ALL 

APPLICABLE ELECTRICAL CODES. 

TO AVOID ELECTRIC SHOCK: 

BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.

PRODUCT  MUST  BE  CONNECTED TO A  WIRING  SYSTEM  WITH  AN  EQUIPMENT-GROUNDING

CONDUCTOR.  

TO AVOID EXPLOSION: 

MAKE SURE THE SUPPLY VOLTAGE IS WITHIN THE VOLTAGE RATING.

ENSURE THE MARKED T RATING IS LESS THAN THE IGNITION TEMPERATURE OF THE HAZARDOUS

ATMOSPHERE.

DO  NOT  OPERATE  IN AMBIENT  TEMPERATURES  ABOVE  THOSE  INDICATED  ON  THE PRODUCT

NAMEPLATE.

DO  NOT  OPERATE  IF THE  LENS, CORD, SEALS, HOUSING, RECEPTACLES, ETC. IS CRACKED  OR

DAMAGED. IF SO, DISCONTINUE USE AND CONTACT MANUFACTURER FOR REPLACEMENT PARTS.

ALL FASTENERS SHOULD BE PROPERLY SEATED.

WARNING: 

USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE. WHEN EXTENSION 

CORD IS CONNECTED TO A POWER SOURCE IN HAZARDOUS AREA, PLUG AND MATCHING RECEPTACLE 

MUST BE SUITABLE FOR HAZARDOUS LOCATION INVOLVED. IMPROPER USE OF THIS DEVICE, ASSOCIATED 

PLUG, RECEPTACLE, AND CORD CAN LEAD TO SERIOUS INJURIES OR DEATH TO PERSONNEL. 

PERIODIC INSPECTION OF THE RECEPTACLE AND CORD IS NECESSARY.

 

THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY 

ARE FOUND, THE CORD MUST BE REPLACED BEFORE RESUMING USE OF THE UNIT.  

ELECTRICAL POWER SUPPLY MUST BE “OFF” BEFORE AND DURING INSTALLATION AND MAINTENANCE. 

INSTALLATION AND MAINTENANCE PROCEDURE MUST BE PERFORMED BY A TRAINED AND COMPETENT 

ELECTRICIAN. 

IF ANY PARTS OF THE RECEPTACLE OR PLUG APPEAR TO BE MISSING, BROKEN, OR SHOW SIGNS OR 

DAMAGE, DISCONTINUE USE IMMEDIATELY. REPLACE WITH THE PROPER REPLACEMENT PART(S) BEFORE 

CONTINUING SERVICE. 

WARNING: 

USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE. IF WIRING OR LAMP REPLACEMENT 

INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, THE HANDLAMP MAY NOT BE SUITABLE FOR THE HAZARDOUS LOCATION INVOLVED. 

WHEN HANDLAMP IS CONNECTED TO A POWER SOURCE IN HAZARDOUS AREA, PLUG AND MATCHING RECEPTACLE MUST BE SUITABLE 

FOR HAZARDOUS LOCATION INVOLVED. WHEN HANDLAMP IS CONNECTED TO POWER SOURCES OUTSIDE OF HAZARDOUS AREA, 

STANDARD DUTY PLUGS AND RECEPTACLES MAY BE USED.  

STANDARD PLUG AND TRANSFORMER MUST ONLY BE CONNECTED TO A RECEPTACLE LOCATED OUTSIDE THE 

HAZARDOUS AREA! 

IMPROPER USE OF THIS HANDLAMP, ASSOCIATED PLUG, RECEPTACLE, AND CORD CAN LEAD TO SERIOUS INJURIES OR DEATH TO 

PERSONNEL. 

PERIODIC INSPECTION OF THE HANDLAMP AND CORD IS NECESSARY.

 

THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY ARE FOUND, THE CORD MUST 

BE REPLACED BEFORE RESUMING USE OF THE HANDLAMP.  

THE GLOBE IS MADE OF TEMPERED GLASS. IF THIS GLASS BECOMES SCRATCHED OR CHIPPED IT SHOULD BE REPLACED IMMEDIATELY. 

Содержание EPL-20W-HID-X12V-347V-GR50

Страница 1: ...HESE INSTRUCTIONS FOR FUTURE REFERENCE THE EPL 20W HID X12V 347V GR50 MUST BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES PROPER GROUNDING IS REQUIRED FOR SAFETY W...

Страница 2: ...CESSARY THE CORD MUST BE ROUTINELY CHECKED FOR CUTS BREAKS OR ANY SEVERE ABRASIONS AND IF ANY ARE FOUND THE CORD MUST BE REPLACED BEFORE RESUMING USE OF THE UNIT ELECTRICAL POWER SUPPLY MUST BE OFF BE...

Страница 3: ...be required Universal voltage driver permits operation at 347V AC stepped down to 12V DC Warning Check product label for correct input voltage Attach supply line wires to the appropriate light fixtur...

Страница 4: ...the light without worry of damage or cool down It is suggested not to flash the light as this will shorten run time and lamp life INSTALLATION Electrical wiring on the reel must be done by a qualified...

Страница 5: ...y in the event of mounting failure WARNING Modifications of this equipment may cause excessive wear and will void the warranty Contact the manufacturer regarding changes or modifications of equipment...

Страница 6: ...eel cable more evenly 2 The cable should not pile against either end of the spool during winding as this will tend to inhibit level winding of the cable 3 The guide should be secured at the best of tw...

Страница 7: ...the drum and cable together in the direction of pay out in order to pre tension the spring The number of pre tension turns is determined by cable size and footage Usually four to sixteen turns is suff...

Страница 8: ...proper seating and all are in good condition with no marks or dents Replace all seals as necessary Lubricate with silicon lubricant or low mineral petroleum jelly A discoloration of the lamp reflecto...

Страница 9: ...retraction rate 3 Properly adjust cable guide Cable twisting and knotting 1 Improperly installed cable 2 Cable rubbing on or bending around fixed object 3 Excessive spring tension 4 Inadequate anchor...