background image

EPL-16BS-1X150LED-25

Larson Electronics, LLC

 

  Phone: (800) 369-6671 

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

2

 of 

4

 

WARNING 

TO AVOID THE RISK OF FIRE, EXPLOSION OR ELECTRIC SHOCK, THIS PRODUCT SHOULD BE INSTALLED, 

INSPECTED AND MAINTAINED BY A QUALIFIED ELECTRICIAN ONLY, IN ACCORDANCE WITH ALL 

APPLICABLE ELECTRICAL CODES. 

TO AVOID ELECTRIC SHOCK: 

BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.

PRODUCT  MUST  BE  CONNECTED TO A  WIRING  SYSTEM  WITH  AN  EQUIPMENT-GROUNDING

CONDUCTOR.  

TO AVOID EXPLOSION: 

MAKE SURE THE SUPPLY VOLTAGE IS WITHIN THE VOLTAGE RATING.

ENSURE THE MARKED T RATING IS LESS THAN THE IGNITION TEMPERATURE OF THE HAZARDOUS

ATMOSPHERE.

DO  NOT  OPERATE  IN AMBIENT  TEMPERATURES  ABOVE  THOSE  INDICATED  ON  THE PRODUCT

NAMEPLATE.

DO  NOT  OPERATE  IF THE  LENS, CORD, SEALS, HOUSING, RECEPTACLES, ETC. IS CRACKED  OR

DAMAGED. IF SO, DISCONTINUE USE AND CONTACT MANUFACTURER FOR REPLACEMENT PARTS.

ALL FASTENERS SHOULD BE PROPERLY SEATED.

The EPL-16BS-1X150LED-25 from Larson Electronics is an Explosion Proof LED Base Stand Light that is rated Class I 

Divisions 1 & 2 Groups C & D and Class II Divisions 1 & 2 and uses a 22 inch Cree LED light head to produce 21,000 

lumens of light while drawing only 150 watts. The EPL-16BS-1X150LED-25 is mounted on a convenient aluminum base 

stand that provides a stable way to hold the light head in position in the work place.

WIRING 
Standard pigtail(flying leads) wiring 

We strongly encourage a licensed electrician install this product

, in all locations especially in outdoor areas 

where weatherproofing may be required. Universal voltage driver permits operation at 1

2

0V  -  277V AC, 50 or 60Hz

.

Warning: 

Check product label for correct input voltage!

 

Attach supply line wires to the appropriate light fixture wires as shown 

in the diagram 

 

Secure each pair of wires according to the diagram. Utilize a junction box or 

similar  device  and  take  precautionary  steps  for  weatherproofing  all 

connections if installed in a location where water may come in contact with the 

unit. Ensure the unit is properly grounded and that wiring is done according to 

all local and national electrical/building codes. 

Exp Cord Cap 

Position  device  near  work  area  for  operation.  Run  cable  to  nearby  power 

source. Insert and twist-lock explosion-proof plug into a compatible receptacle within 

the hazardous environment. See 

plug operation

 below. 

PLUG OPERATION 

Electrical connection between plug and compatible receptacle is accomplished 

after plug fully inserts into receptacle and rotated clockwise. 

1.

Lift receptacle door and locate polarization on mating plug pin and

 

receptacle face. Insert plug straight all the way into receptacle until it

 

cannot go further.

2.

Rotate plug clockwise limit (37º), this closes internal contacts and

 

completes circuit. This also mechanically locks plug into receptacle so it

 

cannot be pulled out.

3.

To remove plug, push plug inward and turn to counterclockwise, pull plug

 

straight out.

Отзывы: