WARNING
TO AVOID THE RISK OF FIRE, EXPLOSION OR ELECTRIC SHOCK, THIS PRODUCT SHOULD BE INSTALLED,
INSPECTED AND MAINTAINED BY A QUALIFIED ELECTRICIAN ONLY, IN ACCORDANCE WITH ALL
APPLICABLE ELECTRICAL CODES.
TO AVOID ELECTRIC SHOCK:
•
BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.
•
PRODUCT MUST BE CONNECTED TO A WIRING SYSTEM WITH AN EQUIPMENT-GROUNDING
CONDUCTOR.
TO AVOID EXPLOSION:
•
MAKE SURE THE SUPPLY VOLTAGE IS WITHIN THE VOLTAGE RATING.
•
ENSURE THE MARKED T RATING IS LESS THAN THE IGNITION TEMPERATURE OF THE HAZARDOUS
ATMOSPHERE.
•
DO NOT OPERATE IN AMBIENT TEMPERATURES ABOVE THOSE INDICATED ON THE PRODUCT
NAMEPLATE.
•
DO NOT OPERATE IF THE LENS, CORD, SEALS, HOUSING, RECEPTACLES, ETC. IS CRACKED OR
DAMAGED. IF SO, DISCONTINUE USE AND CONTACT MANUFACTURER FOR REPLACEMENT PARTS.
•
ALL FASTENERS SHOULD BE PROPERLY SEATED.
The EPL-16BS-1X150LED-25 from Larson Electronics is an Explosion Proof LED Base Stand Light that is rated Class I
Divisions 1 & 2 Groups C & D and Class II Divisions 1 & 2 and uses a 22 inch Cree LED light head to produce 21,000
lumens of light while drawing only 150 watts. The EPL-16BS-1X150LED-25 is mounted on a convenient aluminum base
stand that provides a stable way to hold the light head in position in the work place.
WIRING
Standard pigtail(flying leads) wiring
We strongly encourage a licensed electrician install this product
, in all locations especially in outdoor areas
where weatherproofing may be required. Universal voltage driver permits operation at 1
2
0V - 277V AC, 50 or 60Hz
.
Warning:
Check product label for correct input voltage!
Attach supply line wires to the appropriate light fixture wires as shown
in the diagram
Secure each pair of wires according to the diagram. Utilize a junction box or
similar device and take precautionary steps for weatherproofing all
connections if installed in a location where water may come in contact with the
unit. Ensure the unit is properly grounded and that wiring is done according to
all local and national electrical/building codes.
Exp Cord Cap
Position device near work area for operation. Run cable to nearby power
source. Insert and twist-lock explosion-proof plug into a compatible receptacle within
the hazardous environment. See
plug operation
below.
PLUG OPERATION
Electrical connection between plug and compatible receptacle is accomplished
after plug fully inserts into receptacle and rotated clockwise.
1.
Lift receptacle door and locate polarization on mating plug pin and
receptacle face. Insert plug straight all the way into receptacle until it
cannot go further.
2.
Rotate plug clockwise limit (37º), this closes internal contacts and
completes circuit. This also mechanically locks plug into receptacle so it
cannot be pulled out.
3.
To remove plug, push plug inward and turn to counterclockwise, pull plug
straight out.