Figure 3-18 Access-T 1500 Module (Side View), DIP Switch Location
Hardware Configuration/Operation Mode
Before power-up, Access-T must be configured for the number of DTE ports
and the operation mode via the DIP switches on the rear panel of the unit. The
Access-T software can be configured to operate with a 1-port, 2-port, or 4-port
unit in either master or slave mode. For a more detailed explanation on master
and slave modes, consult Chapter 8.
DIP switch settings for all hardware configuration/operation mode combina-
tions are provided in Table 3-A. Set DIP switches according to the procedure
described in Setting DIP Switches.
CAUTION: Series 400 units have a second set of DIP
switches on the rear panel (
SP11
). Verify that all these
DIP switches are CLOSED (down) except switch 8,
which must be OPEN (up).
OP
EN
1
2
3
4
5
6
7
8
SP1
RP15
U15
TP3
3
GN
D
Q7
Top
Thumbscrew
ACST-0351-005
Chapter 3
June 1996
Installation
3-27