LT-3100S GMDSS User & Installation Manual Rev. 1.02
Using the system
Lars Thrane A/S
www.thrane.eu
Page 46 of 71
Temporary silence
Active unacknowledged alerts cause a short but periodically repeated audible signal. To temporarily silence
all alerts (and thus the audible signal)
, press the “Silence
BAM
” soft key.
The temporary silence period
expires after 30 s, after which active silenced alerts become active unacknowledged alerts again, causing
the audible signal to resume.
Priority
Icon
State
Condition
Audible signal
Warning
Active
–
unacknowledged
Alert condition present.
Alert not acknowledged.
Yes
Active
–
silenced
Alert condition present.
Alert not acknowledged, but
audible signal has been silenced by
the operator.
No
Active
–
acknowledged
Alert condition present.
Alert acknowledged by the
operator.
No
Active
–
responsibility
transferred
Alert condition present.
A function of the BAM compliant
equipment with additional system
knowledge has taken over.
No
Rectified
–
unacknowledged
Alert condition rectified.
Alert still unacknowledged.
No
None
Normal
No alert condition present.
No
Caution
Active
Alert condition present.
No
None
Normal
No alert condition present.
No
Table 18: BAM alert icons, priority and state