12
GIOTTO
English
N
N5
N4
N1
N3
OFF
N2
CORRECT PROCEDURE OF DECOMPRESSION
• Insert the gun clamp (
N1
).
• Move the ON/OFF switch (
N2
) to the
OFF
position
(0)
to stop
the equipment.
• Disconnect the power supply cable (
N3
).
• Release the gun clamp (
N4
). Point the gun at the tank of the
product and press the trigger to release pressure. At the end
of the operation, insert the gun clamp.
• Open the re-circulation valve (
N5
) to release residual pressure.
WARNING
:
If the equipment is still under pressure after performing the operations above described
because of the nozzle or the flexible hose clogged, proceed as follows:
• Loosen very slowly the gun nozzle.
• Release the clamp.
• Point the gun at the container of the product and press the trigger to release
pressure.
• Loosen very slowly the fitting of connection from the flexible hose to the gun.
• Clean or replace the flexible hose and the nozzle.