REPLACING HYDRAULIC OIL
After operating for 100 hours, replace the oil in the pump;
• Discharge the waste oil through the
hydraulic filter
fitted at
the bottom of the pump casing.
• Clean and, if necessary, replace the worn seals.
• Replace the filter in its seat by screwing it tightly.
• Fill the pump with the recommended oil until it reaches the
maximum level.
• Then, substitute the oil every 250 hours.
CLEANING THE MOTOR COOLING FAN GUARD
Clean the motor cooling fan protection guard periodically to
ensure the best cooling.
ROUTINE MAINTENANCE
TOP UP HYDRAULIC OIL
With each start up, check the hydraulic oil level by looking through
the gauge on the side of the hydraulic body. If necessary, use
“AGIP OSO 46 type hydraulic oil”
to top up the level.
RELEASE THE SUCTION VALVE
If the pump malfunctions, release the suction valve fitted on the
head of the pump in the following way:
• Remove the suction hose fitting and release the valve by
inserting a rigid rod (
I1
) with a diameter of no more than 15
mm.
CLEANING THE COMPRESSION VALVE
When the compression valve must be removed, clean it with
specific solvents depending on the type of paint used and refit
all parts by inverting the removal order.