Operation manual
- 7 -
1.2 Safety Precautions during Operation:
General Precautions:
1. The operator must employ safe working practices and observe all related local work safety
requirements and regulations.
2. If any of the following statements does not comply with local legislation, the stricter of the
two shall apply.
3. Installation, operation, maintenance and repair work must only be performed by authorized,
trained, specialized personnel.
4. The compressor is not considered capable of producing air of breathing quality. For air of
breathing quality, the compressed air must be adequately purified according to local
legislation and standards.
5. Before any maintenance, repair work, adjustment or any other non-routine checks, stop the
compressor, press the emergency stop button, switch off the voltage and depressurize the
compressor, in addition, the power isolating switch must be opened and locked.
6. Never play with compressed air. Do not apply the air to your skin or direct an air stream at
people. Never use the air to clean dirt from your clothes. When using the air to clean
equipment, do so with extreme caution and wear eye protection.
All responsibility for any damage or injury resulting from neglecting these
precautions, or non-observance of the normal caution and care required for
installation, operation, maintenance and repair, even if not expressly stated,
will be disclaimed by the manufacturer.
PRECAUTIONS DURING OPERATION:
1. Use only the correct type and size of hose end fittings and connections. When blowing
through a hose or air line, ensure that the open end is held securely. A free end will whip and
may cause injury or death. Make sure that a hose is fully depressurized before disconnecting
it.
2. Persons switching on remotely controlled machines shall take adequate precautions to
ensure that there is no one checking or working on the machine. TO this end, a suitable
notice shall be affixed to the remote start equipment.
3. Never operate the machine when there is a possibility of taking in flammable or toxic fumes,
vapour or particles.
4. Never operate the machine below or in excess of its limit ratings.
5. Keep all bodywork doors shut during operation. The doors may be opened for short periods
only, E.G.. to carry out routine checks. Wear ear protectors when open a door.
6. People staying in environments or room s where the sound pressure level reaches or
exceed 90 Db(A) shall wear ear protectors.
7. Periodically check that:
1) All guards are in place and securely fastened
2) All hoses and/or pipes inside the machine are in good condition, secure and not rubbing.
3) There are no leaks
4) All fasteners are tight
5) All electrical leads are secure and in good order
6) Safety valves and other pressure-relief device are not obstructed by dirt or paint.
7) Air outlet valve and air net, i.e. pipe, coupling, manifolds, valves, hosed, etc. are in good
repair, free of wear or abuse.
8. If warm cooling air from compressors is used in air heating system, e.g. to warm up a
Содержание V120103-RS11
Страница 11: ...Operation manual 11 Rotation In Direction Of Arrow Emergency Stop Switch Stop Switch Start up Switch ...
Страница 17: ...Operation manual 17 Figure 2 2 Installation Drawings ...
Страница 25: ...Operation manual 25 Figure 4 8 Trouble Display ...
Страница 27: ...Operation manual 27 Figure 4 9 Alarming Display Figure 4 10 Parameter Display ...
Страница 41: ...Operation manual 41 ...
Страница 42: ...Operation manual 42 Figure 6 5 a the Electrical Drawing 230 Voltage ...
Страница 43: ...Operation manual 43 ...
Страница 44: ...Operation manual 44 Figure 6 5 b the Electrical Drawing 575 Voltage ...
Страница 59: ...Operation manual 59 ...
Страница 60: ...Operation manual 60 Electrical Main Parts List ...
Страница 61: ...Operation manual 61 9 2 LPRS11 575V the P N of LaPlante is 001118 001118 Exploded Drawing ...
Страница 62: ...Operation manual 62 001118 Parts List ...
Страница 63: ...Operation manual 63 Electrical Main Parts List ...