If synthetic lubricants are not available contact your local lubricant supplier a lubricant that
meets the specification in Table 1 below.
3.3 Electric Specification Sheet
Table 3-2 cable size, overload relay and fuses
Description
Voltage(V)
AMP (A)
SF AMP (A)
Frequency(HZ)
LPRS-11
230
23.6
27.1
60
No. 10 Wire
460
11.8
13.6
60
No. 14 Wire
Inlet Cable
Size No.
575
10.2
11.8
60
No. 14 Wire
230
-
-
60
22~30
460
-
-
60
12.5~18
Main Overload
Relay (A)
575
-
-
60
8.5~12.5
As a general rule take the motors full load amp(FLA) X1.25 or (25%) = to determine
your breaker & wire size;
CAUTION
:
All electrical work must be performed by a qualified electrician and must conform to
national, state, and local electrical code in your area.
NOTE:
- The starting method is delta
- When change the voltage, the electrical component will be changed;
- Component is CSA or UL cert.
Содержание V120103-RS11
Страница 11: ...Operation manual 11 Rotation In Direction Of Arrow Emergency Stop Switch Stop Switch Start up Switch ...
Страница 17: ...Operation manual 17 Figure 2 2 Installation Drawings ...
Страница 25: ...Operation manual 25 Figure 4 8 Trouble Display ...
Страница 27: ...Operation manual 27 Figure 4 9 Alarming Display Figure 4 10 Parameter Display ...
Страница 41: ...Operation manual 41 ...
Страница 42: ...Operation manual 42 Figure 6 5 a the Electrical Drawing 230 Voltage ...
Страница 43: ...Operation manual 43 ...
Страница 44: ...Operation manual 44 Figure 6 5 b the Electrical Drawing 575 Voltage ...
Страница 59: ...Operation manual 59 ...
Страница 60: ...Operation manual 60 Electrical Main Parts List ...
Страница 61: ...Operation manual 61 9 2 LPRS11 575V the P N of LaPlante is 001118 001118 Exploded Drawing ...
Страница 62: ...Operation manual 62 001118 Parts List ...
Страница 63: ...Operation manual 63 Electrical Main Parts List ...