![Laon People LPMVC-CL025M Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/laon-people/lpmvc-cl025m/lpmvc-cl025m_user-manual_3615334038.webp)
LPMVC-CL025M Manual
More than Imaging – Laon People
38
2016-03-04
5.10.1.
Free-Run Mode
The cycle of the internal trigger signal in the Free-Run mode is decided by the one frame
image data transmission time and the sensor exposure time.
The one frame image data transmission time depends on the size of the image (ROI).
If the one frame image data transmission time is shorter than the sensor exposure time,
the frame rate will be ‘1 / (the sensor exposure time)’, and if the sensor exposure time is
shorter than the time one frame of image data is transmitted, the frame rate is '1 / (the
one frame image data transmission time).
5.10.2.
External Sync Mode (Pulse Width Trigger)
In the External Sync Mode, the Camera maintains the standby status until the external
trigger signal is input and then exposes the sensor as long as the trigger signal width
and transfer the image data. In order to operate the camera with External Sync Mode,
User should the Trigger Source by the External Trigger port or the CC1 port and should
set the Sensor Exposure Time to the ‘
Pulse Width Trigger
’. In External Sync Mode, it is
impossible to control the exposure time and the frame rate because the control power of
the exposure time of the sensor and the camera's frame rate is given to the external
trigger device.
Figure 26. Timing Chart of Free-Run Mode
Figure 27. Timing Chart of Pulse Width Trigger Mode
Содержание LPMVC-CL025M
Страница 1: ...2016 03 04 LPMVC CL025M User Manual Version 1 0...
Страница 22: ...LPMVC CL025M Manual More than Imaging Laon People 22 2016 03 04 Figure 9 Parallel Data Mapped to LVDS outs...
Страница 23: ...LPMVC CL025M Manual More than Imaging Laon People 23 2016 03 04 Table 6 Camera Link TAP Port Assignments...
Страница 33: ...LPMVC CL025M Manual More than Imaging Laon People 33 2016 03 04 Figure 20 Horizontal Timing Chart of 8Tap...
Страница 34: ...LPMVC CL025M Manual More than Imaging Laon People 34 2016 03 04 Figure 21 Horizontal Timing Chart of 10Tap...