There are temperature sensors within the switch to monitor the temperature inside the switch. If the power 

supply within the switch gets too hot, all ports will be shut down regardless of priority. This is to prevent the 

switch from overheating and causing permanent damage. 

PoE Port Acceptable Power

 

Port 1 

Device 

Power 

(W) 

Port 2 

Device 

Power 

(W) 

Port 3 

Device 

Power 

(W) 

Port 4 

Device 

Power 

(W) 

Acceptable for -AC 

Version? 

Acceptable for -DC 

Version? 

Acceptable for -PD 

Version? 

15.4 

15.4 

15.4 

15.4 

Yes 

Yes 

Yes 

30 

30 

30 

30 

Yes 

Yes 

No, total power 

exceeds 90W 

30 

30 

30 

Yes 

Yes 

Yes, if using 802.3bt 

compliant PSE 

60 

60 

60 

60 

No, total power 

exceeds 180W 

Yes 

No, total power 

exceeds 90W 

60 

45 

45 

30 

Yes 

Yes 

No, total power 

exceeds 90W 

90 

Yes 

Yes 

Yes, if using 802.3bt 

compliant PSE 

90 

90 

No, 90W devices 

adjacent 

No, 90W devices 

adjacent 

No, total power 

exceeds 90W 

90 

90 

Yes 

Yes 

No, total power 

exceeds 90W 

90 

15.4 

90 

15.4 

No, total power 

exceeds 180W 

Yes 

No, total power 

exceeds 90W 

90 

90 

90 

90 

No, total power 

exceeds 180W 

No, total power 

exceeds 240W 

No, total power 

exceeds 90W 

CUSTOMER

 

ACCESS 

Use a 3/8" nut driver to unlock the enclosure. Push in and lift up on the 
plastic lever to the right of the 3/8" bolt. 
There is also access for an additional lock (not included). 

 

Console Port 

The Console port provides an RJ45 connector for serial connection to a network PC running a terminal emulation 
package such as Hyper Term or PuTTY. See the SESPM1040-541-LT-xx Operation Guide for CLI command 
information. 
 

 

Содержание SESPM1040-541-LT Series

Страница 1: ...41 LT xx Self Enclosed Managed Hardened Gigabit Ethernet PoE Switch 4 10 100 1000Base T PoE Ports 1 10 100 1000Base T or 100 1000Base X SFP RJ 45 Combo Ports Install Guide Part Number 33772 Revision F...

Страница 2: ...no obligation to update the information in this publication Lantronix does not make and specifically disclaims all warranties of any kind express implied or otherwise regarding title non infringement...

Страница 3: ...040 541 LT PD Components 15 Dimensions 16 Related Manuals 17 For More Information 17 2 Switch Installation 18 System Requirements 18 Package Contents 18 Unpacking 18 Cautions and Warnings 19 Warnings...

Страница 4: ...Version 39 PD Version 39 Composite Fiber 42 SESPM 4P FMK Fiber Tray Option 42 Boot Process 42 LED Locations 43 LED Descriptions 43 Removing the Switch 44 4 Additional Information 45 Q A 45 Troubleshoo...

Страница 5: ...ic Emissions 55 Temperature and Humidity 55 Backward Compatibility 56 Identification 56 145 7 Protocol Implementation Conformance Statement PICS proforma for Clause 145 PoE 56 Compliance Information 5...

Страница 6: ...tion on page 31 The PD version includes a 12V Aux port which can be used to provide auxiliary power to a PC lighting or other accessories On all versions a second 10 100 1000Base T RJ 45 maintenance o...

Страница 7: ...mbo Port Module to activate a 2nd combination 10 100 1000Base T maintenance port or 100 1000Base X combo uplink port and provide 24VDC for non standard PoE powered devices Optional Accessories sold se...

Страница 8: ...59VDC PD Version PoE Powered 90W PoE or standalone DC power supply Power Consumption AC version 10 vA DC version 10 W PoE powered PD version 5 W Power over Ethernet PoE Max PoE Budget AC version 180 W...

Страница 9: ...eliable technology and it is RoHS compliant Supported standards include ISO IEC 14443 A B MIFARE ISO IEC 18092 JIS X 6319 4 FeliCa NFCIP 1 ECMA 3 40 and NFC Forum Tag 4 It operates at a Frequency of 1...

Страница 10: ...E to other devices or to receive and provide PoE where external power sources are not available 6kV Surge Protection Protects switch from lightning or other surges in current NEMA 4X IP66 Rated Enclos...

Страница 11: ...as pair swaps pair polarity and excessive skew It can also detect cable opens shorts or impedance mismatch in the cable and report accurately within one meter the distance to the fault MAC Address Tab...

Страница 12: ...Lantronix SESPM1040 541 LT xx Install Guide 33772 Rev F https www lantronix com Page 12 of 64 Components View The basic switch components are shown below Device Views...

Страница 13: ...Lantronix SESPM1040 541 LT xx Install Guide 33772 Rev F https www lantronix com Page 13 of 64 SESPM1040 541 LT AC Components...

Страница 14: ...Lantronix SESPM1040 541 LT xx Install Guide 33772 Rev F https www lantronix com Page 14 of 64 SESPM1040 541 LT DC Components...

Страница 15: ...Lantronix SESPM1040 541 LT xx Install Guide 33772 Rev F https www lantronix com Page 15 of 64 SESPM1040 541 LT PD Components...

Страница 16: ...Lantronix SESPM1040 541 LT xx Install Guide 33772 Rev F https www lantronix com Page 16 of 64 Dimensions...

Страница 17: ...Option Install Guide 33779 Switch Manager Mobile App for SESPM1040 541 LT xx User Guide 33789 SESPM 2P 24V CP Option Install Guide 33829 SESPM 2P 24V CP Option Quick Start Guide 33832 Release Notes v...

Страница 18: ...they apply System Requirements Tablet any with Android OS and NFC capability Smart Phone any with Android OS and NFC capability OS current Windows or Linux distro Browser current version of most popul...

Страница 19: ...ersions or applications installations See Electrical Safety Warnings on page 23 for Electrical Safety Warnings translated into multiple languages Wiring methods shall be in accordance with the Nationa...

Страница 20: ...ved to de energize the unit Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Warning Ultimate disposal of this product should be handled acco...

Страница 21: ...different switch models Note Tighten the earth ground wire connection screw to 8 10 in lb of torque Caution The input voltage source of the alarm output relay circuit must be an isolated source and li...

Страница 22: ...ing and components c High energy transients coupled onto the LAN cabling system d Voltage potential differences between safety grounds to which various LAN components are connected Such safety hazards...

Страница 23: ...rschriften worden ge nstalleerd S curit lectrique IMPORTANT Cet quipement doit tre utilis conform ment aux instructions de s curit S hk turvallisuus T RKE T m laite on asennettava turvaohjeiden mukais...

Страница 24: ...surge can cause serious damage to mission critical equipment if the IP cameras are connected to the main production network Each of the PoE port interfaces four data pairs as well as the included comb...

Страница 25: ...Warning For ALL versions connect a ground wire to the Ground Post in upper right corner of the enclosure 1 Connect one end of an 18 gauge or greater ground wire to the grounding post using two 5 16 wa...

Страница 26: ...ocation and secure with mounting screws not included 2 Ground the switch before connecting other cables 3 Disconnect the grounding only after disconnecting all other cables Pole Mount Installation For...

Страница 27: ...rvice Bulletin on Guidelines for Supporting Power Delivery Over Balanced Twisted Pair Cabling o ISO IEC TR 29125 and CENELEC TR 50174 99 1 International cabling guidelines for PoE o ANSI TIA 568 C 2 f...

Страница 28: ...ire gland inserts are provided To maintain NEMA IP rating and Switch warranty be sure to use the most appropriately sized insert for your cable and fill all unused holes with the hole plugs provided W...

Страница 29: ...e air flow Grommet sizes available for the entrance locations of the fiber and cables there are 2 7mm holes in each wire gland standard on the switch The Fiber Management Kit comes with 1 replacement...

Страница 30: ...maintain NEMA IP rating and Warranty Flexible Metal Conduit FMC Short segments of FMC are often used as circuit pigtails between junction boxes and fixtures Whip assemblies are available for sale and...

Страница 31: ...ure Note If using more than one 90W port alternate ports i e no adjacent 90W ports Use ports 1 and 3 or ports 2 and 4 Exception using ports 2 and 3 for 90W is allowed Since the PD version cannot suppl...

Страница 32: ...60 60 60 60 No total power exceeds 180W Yes No total power exceeds 90W 60 45 45 30 Yes Yes No total power exceeds 90W 90 0 0 0 Yes Yes Yes if using 802 3bt compliant PSE 90 90 0 0 No 90W devices adjac...

Страница 33: ...Industrial rated models must be used for outdoor switch installation See Lantronix Hardened SFP webpage for more SFP information SFP Orientation The FOA Fiber Optic Association is an international non...

Страница 34: ...factory settings displays in the Web UI Note that you can also perform a Restart or Reset from the Web UI You can perform a Restore system configuration copy command or Reload reload command from the...

Страница 35: ...ose tasks when desired The following messages will appear on the user console note that there will be a delay before the last line appears while the factory settings are applied to the system System B...

Страница 36: ...is via an external PSE that can classify with IEEE 802 3bt Type 4 Class 8 devices such as the SESPM1040 541 LT AC and DC The PD can also be powered by a standalone DC power supply The PD version feat...

Страница 37: ...gs Voltage 300 VAC Temperature 105 deg C Flame Rating VW 1 Conductor Wire Size 18 AWG Number 3 Conductor Material Bare Copper Stranding 41 0 16 mm Insulator Material PVC Color White Black Green Yellow...

Страница 38: ...6 Connect data to switch a Run Ethernet cable through cable glands and insert into port 5 or b run fiber cable s through wire glands and route through fiber management insert SFP into SFP cage and co...

Страница 39: ...ated Power Wire gland Connect DC wires to DC Power Terminal Block in upper left corner of enclosure Note polarity as indicated the DC switch is diode protected against reverse polarity Warning Do not...

Страница 40: ...ust be from an IEEE 802 3bt Type 4 Class 8 compliant PSE device For applications longer distance from power source Composite cable can be used to power the DC or PD unit Data over the fiber Power over...

Страница 41: ...ronix SESPM1040 541 LT xx Install Guide 33772 Rev F https www lantronix com Page 41 of 64 2 Powering a PD beyond 100m 2a Powering a PD beyond 100m from AC or DC using Parallel Copper Fiber Composite C...

Страница 42: ...d to earth ground close to the switch For terminating the power cable there is a screw terminal block on the DC input module or the PD Aux board within the switch For terminating the fiber cable a fib...

Страница 43: ...s and switch power and BLE pairing information as shown and described below 1 PoE Activity LEDs PSE Pair Powered LEDs PSE Port 1 off no power amber 2 pair powered green 4 pair powered PSE Port 2 off n...

Страница 44: ...rade is not in process They slow flash together during a firmware upgrade then revert to heartbeat pattern when firmware upgrade is done success or fail Switch LEDs 6 7 and 8 6 Power Off On Yellow LED...

Страница 45: ...T RJ 45 or 100 1000Base X Combo Port In addition an optional second 10 100 1000Base T RJ 45 or 1000Base X Combo Port is available Q5 What is the 24V Passive PoE Module A5 The optional 24V Passive PoE...

Страница 46: ...ntional intrusions from outside power lines Q12 How does the parallel power and fiber connection work A12 To extend the Ethernet signals beyond the 100m Ethernet cable limitation a combined fiber cabl...

Страница 47: ...ny known issues 3 Check the SESPM1040 541 LT xx webpage for the more current firmware 4 Verify the System Requirements on page 18 5 Verify the Cautions and Warnings on page 23 6 Verify the Cable and C...

Страница 48: ...y reloads or disconnects from inline power verify all electrical connections from the switch to the PD An unreliable connection results in power interruptions and intermittent PD operation such as PD...

Страница 49: ...d device 2 Make sure that your Bluetooth accessory and Android device are close to each other 3 Turn your Bluetooth accessory off and back on again 4 Make sure that your Bluetooth accessory is on and...

Страница 50: ...s other equipment such as LCD displays computer workstations and biomedical equipment Minimum cable type Cat5e recommend Cat 6A cabling Passive PoE Passive PoE describes Ethernet power sources like Po...

Страница 51: ...2009 standard It is backward compatible supports PoE Type 1 devices and provides 30W of DC power to each PoE port up to 25 5W of power for each device PoE Type 2 can support devices such as more compl...

Страница 52: ...A when both PSE and PD are located indoors inside the same building In this environment there has to be electrical isolation between the PoE circuitry and the data circuitry inside a PSE Multi port P...

Страница 53: ...3 84 Watts 13W IP Camera VoIP Phone Wireless Access Point Networked Audio 30W IP Telephone WiMAX Access Point PTZ Camera Remote Computer Terminal 60W Door Access System Video Phone Thin Client 100W D...

Страница 54: ...Standard for Installing Commercial Building Telecommunications Cabling ANSII NECA BICSI 568 describes minimum requirements and procedures for installing the infrastructure for telecoms including balan...

Страница 55: ...etwork or during modification of an existing network Installation and Maintenance Guidelines From IEEE Approved Draft P802 3bt D3 7 Sept 2018 145 6 3 It is a mandatory requirement that sound installat...

Страница 56: ...proforma for Clause 145 PoE From IEEE Approved Draft P802 3bt D3 7 Sept 2018 145 7 2 145 7 2 1 Implementation identification Supplier1 Lantronix Contact point for inquiries about the PICS1 Eric Bass I...

Страница 57: ...y with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operat...

Страница 58: ...its for radio noise for digital apparatus set out in the radio interference regulations of the Canadian Department of Communications Le radio l appareil num rique n met pas de bruits radio lectriques...

Страница 59: ...Lantronix SESPM1040 541 LT xx Install Guide 33772 Rev F https www lantronix com Page 59 of 64 PCB Hardware Revision label example only...

Страница 60: ...__________________________________ Describe any action s already taken to resolve the problem e g changing mode rebooting etc ________________ _________________________________________________________...

Страница 61: ...Its net data rate ranges from 54 Mbit s to 600 Mbit s The IEEE has approved the amendment and it was published in October 2009 Prior to the final ratification enterprises were already migrating to 80...

Страница 62: ...ct against when completely and properly installed Type 4X Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts to pr...

Страница 63: ...Mode B respectively at the PD Power Sourcing Equipment PSE A DTE or midspan device that provides power to a single link section which may also carry data Single signature PD A PD that simultaneously s...

Страница 64: ...arters 48 Discovery Suite 250 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support Online https www lantronix com technical support Sales Offices For a curr...

Отзывы: