Backward Compatibility
Although new features were added, higher power is supported and some algorithms were changed to ensure
interoperability. The idea is that the system will work with legacy Type 1 and Type 2 devices. It should work
automatically, as long as the PSE is capable (in terms of power) of supporting the PD and both are standard
compliant. Should the PD require higher power (IEEE 802.3bt PD) and the PSE cannot support it (IEEE 802.3af
PSE), the PD will either remain off or it will turn on and consume only the power available from the PSE.
The table on PoE backward compatibility is updated every six weeks, after the
take place. The SESPM1040-541-LT-PD requires Type 4 Class 8.
Identification
145.7 Protocol Implementation Conformance Statement (PICS) proforma for Clause 145, PoE
From IEEE Approved Draft P802.3bt/D3.7 Sept 2018 145.7.2.
145.7.2.1 Implementation identification
Supplier
1
Lantronix
Contact point for inquiries about the PICS
1
Eric Bass
Implementation Name(s) and Version(s)
1,3
SESPM1040-541-LT-xx Series
Other information necessary for full identification-
e.g., name(s) and version(s) for machines
and/or operating systems; System Name(s)
2
Power ++ Family
NOTE 1-Required for all implementations
NOTE 2-May be completed as appropriate in meeting the requirements for the identification.
NOTE 3-The terms Name and Version should be interpreted appropriately to correspond with a supplier’s
terminology (e.g., Type, Series, Model).
145.7.2.2 Protocol summary
Identification of protocol standard
IEEE Std 802.3bt-201x, Clause 145, Power over
Ethernet
Identification of amendments and corrigenda to this
PICS proforma that have been completed as part
of this PICS
Have any Exception items been required? No [x ] Yes [ ]
(See Clause 21; the answer Yes means that the implementation does not conform to IEEE Std 802.3bt-201x.)
Date of Statement
1/22/19