Configuration Procedures
There are several ways to configure the SESPM1040-541-LT-xx: using NFC (the easiest way), Web UI, or CLI.
NFC Pre-Configuration (Configuring the Switch Directly in the Box)
After you verify the contents of the box, you can configure the switch directly in the box and unpack the box
contents later at the install location.
1.
Open the packing box.
2.
Configure each switch using the Mobile App on an NFC-enabled smart device.
3.
Select the saved configuration.
4.
Move the device closely over the NFC target on the front cover of the switch.
5.
Hit Tap and Go.
Basic Installation Steps
1.
Pre-configure one or more switches using NFC, BLE, CLI or GUI. Note the BLE MAC address.
2.
If pole mounting, attach optional pole mount brackets. See the SESPM-4P-PMB Kit Option Install Guide.
3.
Attach switch to pole or wall.
4.
Attach ground wire on all models. See
Surge Protection / Grounding and Bonding
on page
5.
If using any optional modules, install them now. See the
a.
For 24V Passive PoE module or Combo Port module, install provided thermal pad under module.
6.
Connect data to switch:
a.
Run Ethernet cable through cable glands and insert into port 5,
or
b.
run fiber cable(s) through wire glands and route through fiber management; insert SFP into SFP cage
and connect fiber to SFP.
7.
Connect PDs to switch; run Ethernet cable from switch PSE ports 1-4 to devices to be connected & powered.
a.
Note if connecting multiple 90W devices, it is recommended that those devices be connected to
ports that are separated from one another. Examples: ports 1 and 3, or ports 1 and 4, or ports 2 and
4; it is also OK to use ports 2 and 3 although they are not separated.
6.
Connect power to switch:
a.
-AC: plug in switch to AC outlet
i.
If hard wiring, cut off power connector and:
1.
Connect to junction box (if allowed);
2.
run cable through conduit and hardwire to junction box (if code requires).
b.
-DC: run DC power cable to switch; connect power.
c.
PoE: Attach PoE cable from power source through cable gland and insert into port 5 or if using
parallel fiber and power cable, run low voltage DC power cable through cable gland and connect to
terminal block on switch.
9.
Close switch door and lock enclosure using hex driver or tool.
10.
When successfully installed, configure ports, power, etc. via BLE, CLI, or Web UI. Note the BLE MAC address.
Defaults
: IP = 192.168.1.10. Login = admin/admin. Console port = 23. Bits per second = 115200, Data bits =