Installation
Installation
2 - 5
The MSS485 is designed to connect to any RS485-based serial device using
either
the screw terminal block connector (as shown in Figure 2-10)
or
the RJ45
connector.
Do not
connect wires to both ports simultaneously.
Figure 2-10:
Connecting Wire to Screw Terminal Block
NOTE:
Lantronix recommends the use of shielded twisted pair cabling for RS-485 serial
connections. To ensure that data wires are connected properly see RS-485
Networking Overview on page 1-2 and Appendix C, Pinouts.
When connecting your RS-485 network to the MSS via the screw terminal block,
you may have to connect from 2 to 6 wires depending upon the desired MSS
usage mode. Do not over-tighten the screws; only light pressure is necessary.
NOTE:
If you would like to change your RS-485 connection at a later time, be sure to
power down the unit before changing cables or DIP switch settings.
3.
Connect the MSS to the Ethernet.
The MSS can be connected to a 10BASE-T Ethernet network. Connect a 10BASE-T
twisted-pair Ethernet cable to the RJ45 connector on the back of the MSS.
The MSS1-T2 can also be connected to a 10BASE2 Ethernet network.
Connect a 10BASE2 thin coaxial cable to the BNC connector on the back
of the MSS. Also attach a valid network terminator if required.
The MSS1-T2 can autosense which of the two Ethernet interfaces has been
connected and operate accordingly.
Do not
connect cables to both interfaces at
the same time.
NOTE:
If you would like to change interfaces at a later time, be sure to power down the unit
before switching Ethernet cables.
4.
Connect a terminal to the MSS485 DB9 console port, if desired.
The terminal will allow you to view commands as you configure the MSS. It will
also display operational and error messages so that you can monitor the unit.
NOTE:
The DB9 console port parameters are 9600 baud, 8 data bits character size, no
parity, and one stop bit.
5.
Set the eight DIP switches on the bottom of the unit to correspond with your
network (MSS483 only). Choose one option from each of the following
functional groupings, and be sure not to mix two-wire and four-wire mode
settings. (See Figure 2-7 on page 2-3 for DIP switch locations.)
NOTE:
Any DIP switch configuration not described here could render your MSS
inoperable. Be sure to follow these instructions carefully.
Screwdriver
Wire
Содержание MSS1-T
Страница 1: ...MSS Reference Manual For Lantronix MSS1 T MSS1 T2 and MSS485 Micro Serial Servers...
Страница 2: ......
Страница 6: ......
Страница 8: ......
Страница 14: ......
Страница 16: ......
Страница 24: ......
Страница 26: ......
Страница 32: ......
Страница 34: ......
Страница 44: ......
Страница 46: ......
Страница 60: ......
Страница 104: ......
Страница 108: ......