27
macros that are defined in Matrix-Hub memory. If a macro name is specified at
the command line, the commands defined for the macro will be listed.
The
MN
command creates a new macro. The name of the new macro must follow
the command or an error message will be returned and a new macro will not be
created. After correctly entering the command (with new macro name), the
Matrix-Hub will prompt the user for the commands that are to be executed when
the macro is run. Once all the commands for the macro have been entered, the
user must press
<ENTER>
at the
Enter macro item:
prompt to exit from
command entry and create the macro.
The
MD
command deletes a macro. The name of the macro to be deleted must
follow at the command line or an error message will be returned and the macro
will not be deleted. When the command is correctly entered, the Matrix-Hub will
ask the user to confirm that the macro will be deleted. Once deleted, a macro is
not recoverable and must be re-entered if it will be used again.
8.6.1 Autoexec Macro
The Matrix-Hub will automatically execute a macro named
AUTOEXEC
at power-
up if a macro with that name has been created. This macro could contain system
default connections or connections for management of power problems. The
execution of the macro cannot be halted unless the macro itself is deleted before
power is turned off and back on. If there is no macro named
AUTOEXEC
, then no
macro will execute at power-up.
8.7 Password Commands
Users are defined or deleted using the password commands. There are two
levels of passwords: level one and level two. Level one passwords allow
complete access to all functions and commands available on the Matrix-Hub.
Level two passwords allow a user to only make or break connections using
entities or macros. A level two password user does not have access to any
commands other than
C
,
D
, or
MR
; the
C
and
D
commands may only be used with
entity names. Entity and macro names cannot be listed, so the level two user
must know the name of the entities or macros before using them.
The user prompt changes according to the password level. For level one
passwords, the prompt is
MatrixHub#
; for level two passwords it is
MatrixHub$
.
The Matrix-Hub is shipped from the factory with two passwords defined: one level
one password, and one leve l two password. The level one password is
mh1
,
Содержание MatriX-Hub Series 1000