30
SW1 – System Use (do not change)
Switch Position
? ? ? ? ?
1
2
3
4
5
6
7
8
on
off
off
off
off
off
off
off
SW2 – IN Port Baud Rate
Switch Position
? ? ? ? ?
Baud
Rate
1
2
3
4
5
6
7
8
19,200
off
off
off
off
off
off
off
off
9600*
off
off
off
off
off
off
on
off
4800
on
on
off
off
off
off
off
on
2400
off
off
on
off
off
off
on
on
*Factory default setting
SW3 – User Interface Options
Switch Position
off
on
1
Display temperature in
?
F
Display temperature in
?
C
2
Do not echo characters
Echo Characters
3
Do not send error
messages
Send error messages
4
Do not add line feed to
output
Add line feed to output
5-7
Not used
Not used
8*
Disable diagnostic
commands
Enable diagnostic
commands
*The diagnostic command setting on position 8 of SW3 is not enabled in normal
operation of the Matrix-Hub. It allows the use of a more basic (but more cryptic)
command language through the control card IN port. This command language is
used mostly for diagnostic purposes, and does not add or take away any
functionality from the Matrix-Hub.