background image

                                                                                                               

 

8 10/100TX with X-Ring Management 

Industrial Switch 

 

 

 

IES-2008 

User Manual 

 

 

 

 

 

 

 

 

 

 

 

Содержание IES-2008

Страница 1: ...8 10 100TX with X Ring Management Industrial Switch IES 2008 User Manual...

Страница 2: ...oftware kernel version hardware version and firmware version If the switch functions have any different from the manual contents description please contact the local sale dealer for more information F...

Страница 3: ...n a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try...

Страница 4: ...scription 3 Physical Dimension 3 Front Panel 3 Reset Button 4 Bottom View 4 DIP switch 4 LED Indicators 6 Ports 7 Cabling 9 Wiring the Power Inputs 10 Wiring the Fault Alarm Contact 10 Wiring the Faul...

Страница 5: ...ing Application 17 Dual Homing Application 18 Web Based Management 19 About Web based Management 19 Preparing for Web Management 19 System Login 20 Port status 21 Port Statistics 22 Port Control 23 Sw...

Страница 6: ...Configuration 40 Redundant ring 44 QoS Configuration 46 IGMP 48 SNMP Configuration 49 Security Manager 51 Configuration Backup 52 TFTP Update Firmware 53 Factory Default 54 System Reboot 55 Save Conf...

Страница 7: ...MDI X function Wide range redundant power design DIN rail and wall mount design Easy configuration design Store and Forward switching architecture Support IEEE 802 1p class of service and provide por...

Страница 8: ...t below to verify them against the checklist 8 10 100TX with redundant ring Web management industrial switch One DIN Rail attached on the switch One wall mount plate and six screws User manual 8 10 10...

Страница 9: ...on and wiring installation Physical Dimension 8 10 100TX with redundant ring Web management industrial switch dimension W x H x D is 54mm x 135mm x 105mm Front Panel The Front Panel of the 8 10 100TX...

Страница 10: ...witch will set all configurations back to default setting Bottom View The bottom panel of the 8 10 100TX with redundant ring Web management industrial switch consists one terminal block connector with...

Страница 11: ...por3 t Alarm If the port s link fails the fault LED will light up OFF Disable port4 Alarm 4 ON Enable port4 Alarm If the port s link fails the fault LED will light up OFF Disable port 5 Alarm 5 ON En...

Страница 12: ...witch after the Redundant ring DIPswitch is set LED Indicators There are 7 diagnostic LEDs located on the front panel of the industrial switch They display real time information of system and optional...

Страница 13: ...attached Yellow The port is operating in full duplex mode Blinks Collision of Packets occurs in the port FDX COL Port 7 8 Off The port in half duplex mode or no device attached Ports RJ 45 ports There...

Страница 14: ...rvers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below s...

Страница 15: ...Cable Schematic Cabling Use four twisted pair Category 5 cabling for RJ 45 port connection The cable between the converter and the link partner switch hub workstation etc must be less than 100 meters...

Страница 16: ...nsert the power wire NOTE The wire range of terminal block is from 12 24 AWG V V V V 1 Insert the positive and negative wires into the V and V connector on the terminal block connector 2 To tighten th...

Страница 17: ...ilure and form an open circuit And the following figure shows an application example for the fault alarm contact NOTE The wire range of terminal block is from 12 24 AWG Fault Alarm Contact 24V DC Buzz...

Страница 18: ...f the DIN Rail is not screwed on the industrial switch please see the following figure to screw the DIN Rail on the switch Follow the below steps to hang the industrial switch Use the screws to screw...

Страница 19: ...rst insert the top of DIN Rail into the track 2 Then lightly push the DIN Rail into the track 3 Check the DIN Rail is tightly on the track 4 To remove the industrial switch from the track reverse step...

Страница 20: ...ve the DIN Rail 2 Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at the corners of t...

Страница 21: ...ire the power please refer to the Wiring the Power Inputs section The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights 5 Prepare th...

Страница 22: ...low Redundant ring Application The industrial switch supports the redundant ring protocol that can help your network system to recovery from network connection failure within 300ms or less and make yo...

Страница 23: ...more than one redundant ring group By using the coupling ring function can connect each redundant ring for the redundant backup It can ensure the transmissions between two ring groups will no failure...

Страница 24: ...t ring group and upper level core switch The Dual Homing function only work when the redundant ring function is active The maximum Dual Homing port is one in a redundant ring group NOTE In Dual Homing...

Страница 25: ...orts Internet Explorer 5 0 And it is applied for Java Applets for reducing network bandwidth consumption enhance access speed and present an easy viewing screen NOTE By default IE5 0 or later version...

Страница 26: ...address of the switch and then Press Enter 3 The login screen will appear right after 4 Key in the user name and password The default user name and password is root 5 Click Enter or OK then the home...

Страница 27: ...at user configured Actual means the current value of the port Speed Duplex Display port connection speed Config means the value that user configured Actual means the current value of the port Flow Con...

Страница 28: ...22 Port information interface Port Statistics Display the current port statistic information Click Clear button to clean all counts Port Statistics Interface...

Страница 29: ...ex mode 6 Flow control Set flow control function is Symmetric or Asymmetric in Full Duplex mode The default value is Disable 7 Click Apply button to apply all configuration 8 The port current configur...

Страница 30: ...Address Display the unique hardware address assigned by manufacturer default Switch settings interface NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose...

Страница 31: ...r mode NOTE 1 If you want to disable the function select the monitor mode as disable 2 Remember to execute the Save Configuration action otherwise the new configuration will lose when the switch power...

Страница 32: ...among only members of the same VLAN group Note all unselected ports are treated as belonging to another single VLAN If the port based VLAN enabled the VLAN tagging is ignored In order for an end stat...

Страница 33: ...27 VLAN PortBase interface 1 Click Add to add a new VLAN group The maximum VLAN group is up to 64 VLAN groups 2 Enter the VLAN name group ID and group the members of VLAN group 3 Click Apply...

Страница 34: ...modify existing VLAN group NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when the switch power off 802 1Q VLAN Tagged based VLAN is an IEEE 802 1Q sp...

Страница 35: ...Management Security In fact it can remote management that includes telnet SNMP and Web browse the switch only when the port of VLAN group ID is equal to the Management VLAN ID Fill the specific VLAN...

Страница 36: ...has the right to remote management the switch 3 Group Name Assign a name for the new VLAN 4 VLAN ID Fill in a VLAN ID 2 4094 The default is 1 5 Select ports from the ports list and then click Add to g...

Страница 37: ...or untagged and then click Apply Tag outgoing frames with VLAN Tagged Untag outgoing frames without VLAN Tagged Port VID Configure port VID settings 1 Port VLAN ID Enter the port VLAN ID 2 Click Appl...

Страница 38: ...of alert e mail event and power alarm You can configure each alert function as you needed Email Alert Configuration When the specific events occur the system will send the alert to the email account...

Страница 39: ...il account must exist on the mail server which user had set up in SMTP Server IP Address column Password The email account password Confirm Password reconfirm the password 4 E mail Address of Receipie...

Страница 40: ...thentication Failure when the SNMP authentication fail the system will send out the alert to the dedicate SMTP server Redundant Ring topology change when the redundant ring topology has changed the sy...

Страница 41: ...es the Relay alarm action Without enabling power alarm function the Relay alarm action will not work even the Relay alarm is set Mark the check box and click Apply button Power Alarm interface IP Conf...

Страница 42: ...k cancel IP Address Assign the IP address that your network is using If DHCP client function is enabling and then user does not need to assign the IP address And the network DHCP server will assign th...

Страница 43: ...time zone for reference Local Time Zone Conversion from UTC Time at 12 00 UTC November Time Zone 1 hour 11am Oscar Time Zone 2 hours 10 am ADT Atlantic Daylight 3 hours 9 am AST Atlantic Standard EDT...

Страница 44: ...SR Zone 4 5 hours 5 pm ZP6 USSR Zone 5 6 hours 6 pm WAST West Australian Standard 7 hours 7 pm CCT China Coast USSR Zone 7 8 hours 8 pm JST Japan Standard USSR Zone 8 9 hours 9 pm EAST East Australian...

Страница 45: ...Configuration IP Security IP security function allows user to assign 10 specific IP addresses which have permission to access the switch through the web browser for the securing switch management 1 En...

Страница 46: ...on of the Spanning Tree Protocol and provides for faster spanning tree convergence after a topology change The system also supports STP and the system will auto detect the connected device that is run...

Страница 47: ...lue between 6 through 40 Hello Time 1 10 the time that controls switch sends out the BPDU packet to check RSTP current status Enter a value between 1 through 10 Forward Delay Time 4 30 the number of s...

Страница 48: ...cked by priority in LAN Enter a number 0 through 240 The value of priority must be the multiple of 16 4 Admin P2P Some of the rapid state transactions that are possible within RSTP are dependent upon...

Страница 49: ...ort to True status 6 Admin Non Stp The port includes the STP mathematic calculation True is not including STP mathematic calculation False is including the STP mathematic calculation 7 Click Apply but...

Страница 50: ...ure The switch supports one Dipswitch for configuring the switch as the ring master or slave mode The ring master has the rights to negotiate and place command to other switches in the redundant ring...

Страница 51: ...ction Marking the check box to enable the coupling ring function Coupling port assign the member port Control port set the switch as the master switch in the coupling ring Enable Dual Homing set up on...

Страница 52: ...e the port priority will follow the default port priority that user has assigned High middle low or lowest COS only the port priority will only follow the COS priority that user has assigned TOS only...

Страница 53: ...l check the TOS value of the received IP packet If the TOS value of received IP packet is 25 priority high and then the packet priority will have highest priority NOTE QoS and Rate control cannot be e...

Страница 54: ...se from each host belonging to the multicast group Report A message sent by a host to the querier to indicate that the host wants to be or is a member of a given group indicated in the report message...

Страница 55: ...fine management stations as trap managers and to enter SNMP community strings Also define a name location and contact person for the switch Fill in the system options data and then click Apply to upda...

Страница 56: ...object information and to set MIB objects 4 Click Add Trap Manager A trap manager is a management station that receives traps the system alerts generated by the switch If no trap manager is defined n...

Страница 57: ...ent security issue 1 User name key in the new user name The default is admin 2 Password key in the new password The default is admin 3 Confirm password re enter the new password 4 Click Apply NOTE Rem...

Страница 58: ...Configuration The restore flash ROM value can be restored from TFTP server but the backup image has to be on the TFTP server The industrial switch will download the image back to the flash from the TF...

Страница 59: ...switch 1 TFTP Server IP Address Fill in the TFTP server IP 2 Backup File Name Fill the file name 3 Click Apply TFTP Backup Configuration interface TFTP Update Firmware Updating the switch firmware Bef...

Страница 60: ...emain as user had been configured Click Default button to reset switch to default setting Factory Default interface Save Configuration Save the industrial switch configuration to the flash memory Powe...

Страница 61: ...acket only are only for ingress packet The egress rate only supports all type packets Band Width The port1 port 8 supports port ingress and egress rate control For example assume port 1 is 10Mbps user...

Страница 62: ...Set up system log events and view the system log events System Log Configuration Viewing the system log events Click Reload button to get newest system log event and press Clear button to clear the lo...

Страница 63: ...m will send out the log information Also per port log events can be selected System event selection 4 selections Device cold start Power status SNMP Authentication Failure and Redundant ring topology...

Страница 64: ...nged the system will produce a log message Port event selection select the per port events Per port has 3 selections Link UP Link Down and Link UP Link Down Disable means no event is selected Link UP...

Страница 65: ...nection does not exceed 100 meters 328 feet Diagnosing LED Indicators the Switch can be easily monitored through panel indicators to assist in identifying problems which describes common problems user...

Страница 66: ...ning tree IEEE802 1w rapid spanning tree IEEE802 1p class of service IEEE802 1Q VLAN Tag Protocol CSMA CD Management SNMP management Web interface management One default button for system default sett...

Страница 67: ...EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m Power Supply 12 48 VDC Redundant power with polarity reverse protect function and connective removable terminal...

Страница 68: ...Alarm configuration Fault alarm redundant ring Class of service IEEE802 1p class of service support Per port provides 4 priority queues Quality of service The quality of service support port based Ta...

Страница 69: ...IGMP v1 and Query mode Up to 256 groups SNTP Simple network time protocol SMTP Simple mail transfer protocol System Event Log 1000 event log entries Management IP security IP address security to preve...

Страница 70: ...256Kbps 512Kbps 1MB 2MB 4MB and 8MB Ingress filter packet type combination rules are Broadcast Multicast Unknown Unicast packet Broadcast Multicast packet Broadcast packet only and all of packet The...

Страница 71: ...RS CE EN 61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 Safety UL cUL CE EN60950 1 Stability testing IEC60068 2 32 F...