9. LANSINOH® BOTTLE WITH NATURALWAVE™ TEAT

Clinically Proven to Reduce Nipple Confusion in Breastfed Babies

The patented NaturalWave™ Teat enables 
baby to replicate natural sucking actions 
learned at the breast.

Exclusive breastfeeding is recommended 
for at least 4-6 weeks if possible before 
introducing a bottle and teat.

Storage & Use

Prior to use, always inspect and pull the teat 
in all directions to check the product. Throw away at the first signs of damage or weakness. 
For safety and hygiene reasons, replace the teat every 7 weeks.

Cleaning

Before first use, boil all parts for 5 minutes to sanitise. Ensure all parts are completely 
covered in water and free floating. Always wash all components of the product immediately 
after each use. The teat can be washed in hot soapy water and rinsed in clean water. 
Dishwasher safe on top rack only. Do not clean with solvents or harsh chemicals.

Assembly

Once thoroughly dry, insert teat through the top of the 
screw cap collar. Attach the screw cap collar securely 
onto the bottle neck. When carrying a full bottle, make 
sure it is closed with the collar in place, taking care to 
position the teat in the center of the collar to activate 
the “spill-proof” function of the product.

Latching on

 

Baby’s lips open outward and latch 

onto the areola

Peristaltic “wave-like” tongue movement

 

Baby’s tongue moves in “wave-like” motion 

to compress nipple and extract milk

Swallowing 

Back of baby’s tongue rises, channeling 

the milk into the esophagus

10. TECHNICAL DATA

1.  Power Supply

Battery operation: 

6 AA size alkaline batteries, all connected in series

Operating time: 

Minimum 30 minutes. Maximum 2 hours. Results are 

dependent on battery freshness and pump settings.

AC Adapter operation: 

100-240 Vac wall plug type AC adapter, galvanically 

isolated with 9Vdc output voltage

Pump power dissipation: 

10.0 Watts maximum

Voltage regulation: 

Linear voltage regulator with low dropout voltage and 

short circuit protection

2. Control System

Control unit: 

Microcontroller with integral program memory

Program memory:

 32K flash ROM, 2K RAM memory

HMI: 

LCD display with LED backlight, soft keypad 

Single/double control: 

Single or double breast pumping possible

Selectable pumping style mode:

 3 pumping style modes are selectable 

and controlled from keypad

Adjustable suction level:

 8 suction levels are selectable and controlled 

from keypad

Suction vacuum level: 

Minimum 80 mmHg, maximum 250 mmHg

Cap

Teat

Collar

Bottle

Insert the 

teat into top 

of the collar

NOTE: 

DO NOT MICROWAVE BREASTMILK! Microwaving alters the 

composition of the milk. Microwaving also may create “hot spots” in the 

milk that could burn the infant.

NOTE:

 DO NOT thaw breastmilk in hot or boiling water.

Thawing

Thaw frozen milk in the refrigerator or place the containers 
under cool running water, gradually warming the water 
until the milk is thawed. Thawed milk can be kept in a 
refrigerator for up to 24 hours.

Breastmilk is not homogenised and you may notice that it separates as it sits. 
Gently swirl thawed milk before feeding to baby to mix the layers that have 
separated. Breastmilk can vary in colour and consistency depending upon the 
time of the day that the milk was expressed, what you have eaten, and the age 
of the baby at the time of pumping. For further advice, please contact your 
healthcare professional.

Precautions

Do not leave bottle in direct sunlight, heat or disinfectant (sterilising solution), as this may 
weaken the teat. Do not clean with or allow teat to come into contact with solvents or 
harsh chemicals. Damage could result. Fill with the required amount of liquid and tighten 
the screw cap before using. Do NOT overfill. Heating in a microwave is NOT recommended 
as it may produce uneven heating and high localised temperatures. If you choose to heat 
liquid this way, DO NOT SEAL BOTTLES. Swirl well before use, and always check the 
temperature before feeding baby. Hot or unevenly heated liquid may burn baby’s mouth. 
Do not warm liquid by placing the bottle directly onto gas or electric rings, warming plates, 
in electric ovens, etc. Wash after every use. Some liquids and sterile solutions may make the 
silicone turn opaque. This does not alter any of its properties.

WARNING!

DO NOT MICROWAVE BREASTMILK! Microwaving alters the composition of the milk 
and may also create “hotspots” in the milk that could burn the infant. Allowing your child 
to use this product for prolonged periods separate from regular mealtimes or to go to 
sleep while drinking liquids, other than water, from this bottle may cause or contribute 
to early childhood tooth decay. Always use this product with adult supervision. Keep all 
components not in use out of the reach of children. Do not leave baby alone with drinking 
equipment due to the risk of choking. Never use teat as a soother. Always check liquid 
temperatures before feeding.

NOTE:

 

DO 

NOT refreeze 

milk once it is 

thawed.

Содержание SM ARTPUMP 2.0

Страница 1: ...1 INSTRUCTIONS FOR USE S M A R T P U M P 2 0 D o u b l e El ectr i c Breast P ump...

Страница 2: ...ions should always be maintained To reduce the risk of burns electrocution fire or injury to persons This product should never be left unattended when plugged in Close supervision is necessary when th...

Страница 3: ...24 27 PLEASE DO NOT RETURN THIS PUMP TO THE RETAILER Lansinoh s dedicated Customer Service team is here to help If you experience any issues with your Lansinoh Smartpump 2 0 breast pump please call 01...

Страница 4: ...ery first time it starts in let down mode suction level 5 When you switch to the expression mode the pump will start in style 2 suction level 3 Adjusting Suction Levels Increase or decrease the suctio...

Страница 5: ...eastmilk Expression Set Includes B1 ComfortFit Breast Cushion 25mm 2 53408 B2 ComfortFit Breast Cushion 30 5mm 2 50419 B3 Smartpump 2 0 Breast Cushion Body 2 53454 B4 Smartpump 2 0 Diaphragm 2 53402 B...

Страница 6: ...te basin that is used only for cleaning infant feeding items 5 Place pump parts on a clean unused tea towel or paper towel in an area protected from dirt and dust Do not use a tea towel to rub or pat...

Страница 7: ...4 Holding the base of the white valve gently secure the valve into the bottom of the breast cushion body 6 Attach end of 300mm tubing to back of diaphragm cap Ensure that tubing is pushed all the way...

Страница 8: ...ng Replace batteries as a simultaneous set Do not mix old and new batteries Do not mix alkaline and standard carbon zinc batteries If batteries are in the pump but AC adapter is in use the pump will u...

Страница 9: ...pass the pre set two minute let down phase or your milk lets down sooner than two minutes press the let down expression toggle button to move to the expression phase 4 Automatic memory function will s...

Страница 10: ...it is not necessary to time your pumping sessions As you get more experienced with pumping you will get a better sense of the time it takes for your body to express your milk using a breast pump If yo...

Страница 11: ...alve with one of the spare valves provided with the product 8 BREASTMILK STORAGE GUIDELINES Breastmilk Storage and Thawing Guidelines for Healthy Term Babies Check with your healthcare professional or...

Страница 12: ...ble and controlled from keypad Suction vacuum level Minimum 80 mmHg maximum 250 mmHg Cap Teat Collar Bottle Insert the teat into top of the collar NOTE DO NOT MICROWAVE BREASTMILK Microwaving alters t...

Страница 13: ...is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect...

Страница 14: ...urbances induced by RF fields c d o IEC 61000 4 6 3 V m 0 15 MHz 80 MHz 6 V m in ISM bands between 0 15 MHz and 80 MHz n 80 AM at 1 kHz e 3 V m 0 15 MHz 80 MHz 6 V m in ISM and amatuer radio bands bet...

Страница 15: ...DE53260IF0820 2020 Lansinoh Laboratories Inc Alexandria VA USA...