background image

16

17

Regulatory Compliance

Type BF Applied Part

To maintain your power adaptor follow these instructions:

Troubleshooting 

Troubleshooting the Lansinoh Affinity

®

 Pro Double Electric Breast Pump

Interruption of Electrical Service

If you experience an interruption in the normal operation of the electrical and/or  

mechanical functioning of the pump, simply do the following:

n

  Unplug the AC adapter cord from the electrical outlet.

n

  Wait a few seconds, and then plug the AC adapter cord back into the electrical outlet.

  If you still experience electrical failure, try using the pump with the six AA batteries  

making sure the AC adapter is removed.

Discomfort While Pumping

If you feel any discomfort, you may need a different size flange. 

Visit www.lansinohstore.com or call 800-292-4794.

Decreased Suction

If it feels like the suction has decreased, try the following:

n

  Remove the tubing from pump and place a finger over the tubing connector. If you 

feel suction, the pump is operating properly, but the Breastmilk Expression Set may 

not be correctly assembled or the white valve may be damaged. If no suction is felt 

on your finger, try unplugging the adapter from the electrical outlet, wait a few  

seconds, and plug it back into the electrical outlet.

n

  Make sure the Breastmilk Expression Set has been properly assembled. Check the  

assembly information in the section “Assembling the Breastmilk Expression Set”, 

page 10

.

n

  Inspect the white valve for a tear or pinhole. This component is critical to achieving 

proper suction. Replace the white valve with one of the spare valves provided with 

the product. 

n

  When single pumping, check the tubing connector on the front of the pump to make 

sure it is closed for single pumping. If open, close the connector.

n

  If double pumping, ensure that the breastmilk expression set is on both breasts 

before starting the pump.

Increased suction level for single pumping:

If it feels like the suction is higher than usual when single pumping, check that the plug 

for the tubing is clean and that the airway in the plug is not blocked.

DO NOT

 

wrap cord  

of power adaptor  

around the plug body.

CORRECT

DO NOT

 

unplug 

power adaptor by  

pulling on the cord.

CORRECT

DO NOT

 use power adaptor if damaged.

Technical Data 

Power Requirements

AC Adapter (included)
AC Adapter – North American 
Plug Configuration
110Vac/220Vac wall plug type 
AC adaptor, galvanically isolated 
adaptor with 9Vdc output voltage.
Batteries (not included)
6 AA batteries, 1.5V alkaline 
Regulatory Compliance
UL (E302267 ) and CSA approved 
with North American power adapter.

Technical Data

Warranty

Limited Consumer Product Warranty (United States)

This product is warranted to the original consumer purchaser (the “purchaser”)  
to be free from defects in material and workmanship which are not commercially  
acceptable for the period of one year from the date of purchase on the pump 
mechanism and the period of 90 days on all other product components. Warranty 
coverage terminates if you sell or otherwise transfer this product to another person. 
This warranty gives you specific legal rights and you may also have other rights, 
which vary, by location. 
LANSINOH

®

 MAKES NO EXPRESS WARRANTY OF ANY KIND REGARDING  

THE PRODUCT OTHER THAN THOSE WARRANTIES EXPLICITLY SET FORTH 
HEREIN. ANY IMPLIED WARRANTY, INCLUDING ANY IMPLIED WARRANTY  
OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A  
PARTICULAR PURPOSE, TO THE EXTENT PERMITTED BY LAW, SHALL BE  
LIMITED IN DURATION TO A PERIOD OF 90 DAYS FROM THE DATE OF  
PURCHASE BY THE ORIGINAL PURCHASER.
In the event the product is found by Lansinoh

®

 to not meet the above limited  

warranty, as purchaser’s sole and exclusive remedy Lansinoh

®

 will repair or, at the 

option of Lansinoh

®

, replace this product without charge for such replacement or 

parts or labor. 

NOTE: The purchaser shall bear all expense for returning this product 
to Lansinoh

®

. This warranty does not apply to any product that has 

been subjected to misuse, abuse, or alteration.

 

Only Lansinoh

®

 brand replacement parts are recommended for use with Lansinoh

®

 

breastfeeding products. Improper or incorrectly performed maintenance or repair, or 
use of non-Lansinoh

®

 brand replacement parts may invalidate this warranty.

TO THE EXTENT PERMITTED BY LAW, LANSINOH

®

 SHALL NOT BE 

LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES IN-
CLUDING, BUT NOT LIMITED TO, REPLACEMENT COSTS RESULTING 
FROM THE BREACH OF ANY WRITTEN OR IMPLIED WARRANTY.

If you wish to make a claim under this warranty, you must return the product to Lan-
sinoh Laboratories Inc., prepaid, together with your dated bill of sale or other dated 
proof of purchase and a brief statement of the problem, along with a Replacement 
Authorization (RA) number. You may obtain the appropriate Replacement Authoriza-
tion number and shipping address by calling the phone number or sending an email 
to the email address provided below. 
Items returned without an associated Replacement Authorization Number will be 
returned to sender.
To obtain the address to Return Goods or a Replacement Authorization Number:

 800-292-4794 

 

 [email protected]

1008

Operating 

instructions

CLASS II 

equipment

Transport / 

Storage

Transport / 

Storage

!

Caution

Operation

Operation

!

Warning: Children have STRANGLED in cords.

Keep the cords out of the reach of children.

+122 ˚F

-4 ˚F

+122 ˚F

-4 ˚F

20% - 80%

20% - 95%

104 ˚F

41 ˚F

Содержание Affinity PRO

Страница 1: ...1 AFFINITY PRO DOUBLE ELECTRIC BREAST PUMP INSTRUCTIONS FOR USE ...

Страница 2: ... has a range of adjustable pumping rhythms and suc tion strengths that can be customized to your preferences a key difference in the Lansinoh Affinity Pro Double Electric Breast Pump If you have any questions please call our customer service department at 800 292 4794 or email customerservice lansinoh com Important Safeguards 4 Pump Diagram 6 Affinity Pro Breast Pump Parts 8 Cleaning Instructions ...

Страница 3: ...p the cord away from heated surfaces Never use while sleeping or drowsy Never drop or insert any object into any opening or tubing Do not use this product if it is broken or any parts are missing Do not allow small children or pets to play with the pump unit AC adaptor etc Do not use outdoors with the AC adapter or operate where aerosol spray products are being used or where oxygen is being admini...

Страница 4: ...crease Control Button 3 Pumping Rhythm Mode Toggle Button 4 LCD Display with Timer 5 Stimulation Expression Toggle Button 6 Suction Level Decrease Control Button 7 Stimulation Expression Phase Indicator Pump Diagram 1 2 3 4 5 6 7 11 10 9 8 12 Pump Diagram 13 Tubing input 14 Battery compartment for 6 AA batteries not included 15 AC adapter input AC Adapter AA Battery Compartment underneath pump 14 ...

Страница 5: ... for 10 minutes Note Ensure you use enough water to keep parts afloat while boiling Note Do not boil the tubing and tubing connector 2 Remove all parts from water immediately after boiling 3 Completely air dry before assembly and next use Note Partially dried parts may affect operation of the pump Please ensure parts are completely dry before use Cleaning Set aside the tubing and tubing connector ...

Страница 6: ...g effectiveness using the let down reflex stimulated by your baby s sucking You may pump into any standard sized screw top bottle or container Should you choose to use the Lansinoh bottle with a nipple of your own please take the following precautions Always test the temperature of any liquid before feeding your baby Do not let a child take a bottle to bed or self feed for long periods To prevent ...

Страница 7: ...vided three different pumping rhythms so you can maximize your milk production and comfort You should try all three modes to determine which works best for you Note if at any time the suction on your breast reaches uncomfortable levels re duce the suction level by pressing the button on the left side of the LCD screen You can control suction levels in both phases by pressing the and buttons 4 The ...

Страница 8: ...al safety can only be achieved when the breast pump is connected to the AC Power Adapter supplied with the product See Technical Data section page 15 16 Breastmilk Storage Guidelines Note DO NOT store breastmilk in freezer door The door tends to be the warmest part of the freezer Date all breastmilk and use the oldest breastmilk first Thawing Thaw frozen milk in the refrigerator or place the conta...

Страница 9: ...Technical Data Warranty Limited Consumer Product Warranty United States This product is warranted to the original consumer purchaser the purchaser to be free from defects in material and workmanship which are not commercially acceptable for the period of one year from the date of purchase on the pump mechanism and the period of 90 days on all other product components Warranty coverage terminates i...

Страница 10: ...s wireless home network devices mobile phones cordless telephones and their base stations walkie talkies can affect this equipment and should be kept at least a distance 3 5m away from the equipment Stacking This device should not be used adjacent to or stacked with other equipment And if adjacent or stacked use is necessary this device should be observed to verify normal operation in the configur...

Страница 11: ...tor de leche eléctrico doble Lansinoh Affinity Pro es un artículo personal y por razones de higiene nunca se debe compartir ni revender a otras madres Cualquiera de esas acciones anulará la garantía Si usted tiene hepatitis B hepatitis C o el virus de inmunodeficiencia humana VIH extraer la leche materna por medio del Extractor eléctrico doble Lansinoh Affinity Pro no disminuirá ni eliminará el ri...

Страница 12: ...ura 1 Si prefiere saltarse la Fase de estimulación de dos minutos que ya viene programada o si le baja la leche antes de los dos minutos presione el interruptor Estimulación extracción para cambiar a la Fase de extracción El Extractor de leche eléctrico doble Lansinoh Affinity Pro comenzará a funcionar en la Fase de estimulación y luego de dos minutos cambiará automáticamente a la Fase de extracci...

Страница 13: ...a blanca Affinity Pro 2 2 extra 53401 b6 Biberón Affinity Pro de 5 oz 150 ml 2 50414 c Anillo 2 y disco 2 del biberón Affinity Pro 50406 d Adaptador cable de CA Affinity Pro 50409 e Base de biberón Affinity Pro 2 53404 Se incluyen dos válvulas blancas adicionales Puede adquirir por separado copas de succión de mayor tamaño Para solicitar piezas de repuesto o copas de succión de mayor tamaño llame ...

Страница 14: ...de extracción de leche materna por primera vez desármelo y hierva por 10 minutos todas las piezas que entran en contacto con la leche incluye b1 b2 b3 b4 b5 y b6 Nota Asegúrese de usar agua suficiente para mantener todas las piezas a flote durante el hervor Nota No hierva el tubo ni su conector 2 Retire todas las piezas del agua inmediatamente después de hervirlas 3 Séquelas completamente antes de...

Страница 15: ...veces durante su sesión de extracción si presiona el botón de estimulación extracción Cuánto debe durar la extracción Si en lugar de la extracción individual utiliza la doble disminuirá el tiempo que dedica a la extracción La producción de leche materna depende de la demanda por eso si extrae su leche regularmente su cuerpo estará estimulado y usted podrá mantener su suministro de leche Como suced...

Страница 16: ... el adaptador de CA suministrado con el producto Ver la sección Datos técnicos en la página 32 33 Modo de uso del extractor Affinity Puede cambiar el ritmo de extracción del extractor presionando el botón Modo del ritmo de extracción Al presionar este botón cambiará el modo del ritmo de extracción Todas las mamás son diferentes es por ello que hemos establecido tres ritmos de extracción distintos ...

Страница 17: ...terna en la puerta del congelador La puerta tiende a ser el lugar menos frío del congelador Anote la fecha en el recipiente y utilice primero la leche que lleva más tiempo en el congelador Descongelamiento de la leche Descongele la leche en la nevera o coloque el recipiente debajo de un chorro de agua fría y entibie la temperatura del agua gradualmente hasta que la leche se descongele La leche des...

Страница 18: ...zas que no sean de Lansinoh pueden anular esta garantía EN LA MEDIDA EN QUE LA LEY LO PERMITA LANSINOH NO SE RESPONSABILIZARÁ POR NINGÚN DAÑO INCIDENTAL O INDIRECTO LO CUAL INCLUYE PERO NO SE LIMITA AL COSTO DE REEMPLAZO RESULTANTE DE LA INFRACCIÓN DE ALGUNA GARANTÍA ESCRITA O IMPLÍCITA Si desea presentar una reclamación en virtud de esta garantía deberá devolver el producto a Lansinoh Laboratorie...

Страница 19: ...gún problema con este producto sírvase llamar gratis a la línea de servicio al cliente al 800 292 4794 Nuestro representante tendrá mucho gusto de ayudarle Distributed by Distribuido por Lansinoh Laboratories Inc Alexandria VA 22314 USA 800 292 4794 Lansinoh com Lansinoh is a registered trademark of Lansinoh Laboratories Inc 2012 Lansinoh Laboratories Inc All rights reserved Printed in Turkey Lans...

Отзывы: