background image

14

15

Breastmilk Storage Guidelines

Breastmilk Storage and Thawing Guidelines 
For Healthy Term Babies

Check with your healthcare provider or an International Board Certified Lactation 
Consultant for specific storage instructions. 
When you are freezing your breastmilk, do not fill containers more than ¾ full to 
allow for expansion from freezing. Date containers with the date you expressed 
your milk for future reference.

          in a Freezer              in a Refrigerator 

        Room Temperature 

             -0.4 to -4°F                               39°F 

                    66° to 78°F

             -18 to -20˚C                                4˚C 

                    19 to 26˚C

         6 months (ideal)                     72 hours (ideal) 

                  4 hours (ideal)

         up to 12 months            up to 8 days (acceptable            up to 6 hours (acceptable)

            (acceptable)               if collected in a very clean          (Some sources use 8 hours)

 

                        careful way)  

Source: La Leche League International, 2012

Power Options

The pump may be operated under any of the following power supply modes:

AC Adapter 

(included)

6 AA Alkaline Batteries 

(not included)

Do not mix old and new batteries. Do not mix alkaline and standard (carbon-zinc) 
batteries. If batteries are in the pump, but AC adapter is in use, the pump will use 
the adapter to power the pump, not the batteries. For the most economical use, we 
recommend using your pump with the AC adapter provided. Your AC adaptor is a 
universal AC plug adaptor type and can be used with 100 Vac to 240 Vac systems 
with 50Hz and 60Hz mains.

Make sure the batteries are inserted correctly 
according to the polarity (+) and (-)  as indicated. 
Close the compartment by gently pressing the 
cover until it snaps into place.
Remove batteries if pump is not in use for a long 
period of time. Dispose of batteries according 
to regulations for environmental protection and      
recycling. Replace batteries as a simultaneous set.  

Connect the AC adapter to the power receptacle 
located on the right side of the pump. Plug the 
AC adapter into an available electrical outlet.
Electrical safety can only be achieved when the 
breast pump is connected to the AC Power 
Adapter supplied with the product. 
(See “Technical Data” section, page 15-16 )

Breastmilk Storage Guidelines 

Note: DO NOT store breastmilk in freezer door. The door tends to be 
the warmest part of the freezer.

 

 

Date all breastmilk and use the oldest breastmilk first.

Thawing

Thaw frozen milk in the refrigerator or place the containers under cool running  
water, gradually warming the water until the milk is thawed. Thawed milk can be 
kept in a refrigerator for up to 24 hours.
 

NOTE: DO NOT refreeze milk once it is thawed.

Gently shake thawed milk before feeding to baby to mix the layers that have  
separated. Breastmilk is not homogenized and the “cream” will rise to the top of  
the bottle. Breastmilk can vary in color and consistency depending upon the time  
of the day that the milk was expressed, what you have eaten, and the age of the 
baby at the time of pumping.

NOTE: DO NOT MICROWAVE HUMAN MILK! Microwaving alters the 
composition of the milk. Microwaving also may create “hot spots” in 
the milk that could burn the infant.

NOTE: DO NOT thaw breastmilk in hot or boiling water.

Technical Data

1. Power Supply

 

  Battery operation:

 6 AA size alkaline batteries, all connected in series

  Battery operating time:

 Approximately 2 hours with 6 alkaline batteries

  AC Adaptor operation:

 110Vac / 220Vac wall plug type AC adaptor, galvanically isolated  

  with 9Vdc output voltage 

  Pump power dissipation:

10.0 Watts maximum

  Voltage regulation:

 Linear voltage regulator with low dropout voltage and short circuit    

  protection  

2. Control System 

  Control unit:

 Microcontroller with integral program memory

  Program memory:

 32K flash ROM, 2K RAM memory

  HMI:

 LCD display with LED backlight, soft keypad 

  Single / double control:

 Single or double breast pumping possible

  Selectable pumping rhythm mode:

 3 pumping rhythm modes are selectable and 

  controlled from keypad

  Adjustable suction level:

 8 suction levels are selectable and controlled from keypad

  Suction vacuum level:

 Minimum 80 mmHg, maximum 220 mmHg

Содержание Affinity PRO

Страница 1: ...1 AFFINITY PRO DOUBLE ELECTRIC BREAST PUMP INSTRUCTIONS FOR USE ...

Страница 2: ... has a range of adjustable pumping rhythms and suc tion strengths that can be customized to your preferences a key difference in the Lansinoh Affinity Pro Double Electric Breast Pump If you have any questions please call our customer service department at 800 292 4794 or email customerservice lansinoh com Important Safeguards 4 Pump Diagram 6 Affinity Pro Breast Pump Parts 8 Cleaning Instructions ...

Страница 3: ...p the cord away from heated surfaces Never use while sleeping or drowsy Never drop or insert any object into any opening or tubing Do not use this product if it is broken or any parts are missing Do not allow small children or pets to play with the pump unit AC adaptor etc Do not use outdoors with the AC adapter or operate where aerosol spray products are being used or where oxygen is being admini...

Страница 4: ...crease Control Button 3 Pumping Rhythm Mode Toggle Button 4 LCD Display with Timer 5 Stimulation Expression Toggle Button 6 Suction Level Decrease Control Button 7 Stimulation Expression Phase Indicator Pump Diagram 1 2 3 4 5 6 7 11 10 9 8 12 Pump Diagram 13 Tubing input 14 Battery compartment for 6 AA batteries not included 15 AC adapter input AC Adapter AA Battery Compartment underneath pump 14 ...

Страница 5: ... for 10 minutes Note Ensure you use enough water to keep parts afloat while boiling Note Do not boil the tubing and tubing connector 2 Remove all parts from water immediately after boiling 3 Completely air dry before assembly and next use Note Partially dried parts may affect operation of the pump Please ensure parts are completely dry before use Cleaning Set aside the tubing and tubing connector ...

Страница 6: ...g effectiveness using the let down reflex stimulated by your baby s sucking You may pump into any standard sized screw top bottle or container Should you choose to use the Lansinoh bottle with a nipple of your own please take the following precautions Always test the temperature of any liquid before feeding your baby Do not let a child take a bottle to bed or self feed for long periods To prevent ...

Страница 7: ...vided three different pumping rhythms so you can maximize your milk production and comfort You should try all three modes to determine which works best for you Note if at any time the suction on your breast reaches uncomfortable levels re duce the suction level by pressing the button on the left side of the LCD screen You can control suction levels in both phases by pressing the and buttons 4 The ...

Страница 8: ...al safety can only be achieved when the breast pump is connected to the AC Power Adapter supplied with the product See Technical Data section page 15 16 Breastmilk Storage Guidelines Note DO NOT store breastmilk in freezer door The door tends to be the warmest part of the freezer Date all breastmilk and use the oldest breastmilk first Thawing Thaw frozen milk in the refrigerator or place the conta...

Страница 9: ...Technical Data Warranty Limited Consumer Product Warranty United States This product is warranted to the original consumer purchaser the purchaser to be free from defects in material and workmanship which are not commercially acceptable for the period of one year from the date of purchase on the pump mechanism and the period of 90 days on all other product components Warranty coverage terminates i...

Страница 10: ...s wireless home network devices mobile phones cordless telephones and their base stations walkie talkies can affect this equipment and should be kept at least a distance 3 5m away from the equipment Stacking This device should not be used adjacent to or stacked with other equipment And if adjacent or stacked use is necessary this device should be observed to verify normal operation in the configur...

Страница 11: ...tor de leche eléctrico doble Lansinoh Affinity Pro es un artículo personal y por razones de higiene nunca se debe compartir ni revender a otras madres Cualquiera de esas acciones anulará la garantía Si usted tiene hepatitis B hepatitis C o el virus de inmunodeficiencia humana VIH extraer la leche materna por medio del Extractor eléctrico doble Lansinoh Affinity Pro no disminuirá ni eliminará el ri...

Страница 12: ...ura 1 Si prefiere saltarse la Fase de estimulación de dos minutos que ya viene programada o si le baja la leche antes de los dos minutos presione el interruptor Estimulación extracción para cambiar a la Fase de extracción El Extractor de leche eléctrico doble Lansinoh Affinity Pro comenzará a funcionar en la Fase de estimulación y luego de dos minutos cambiará automáticamente a la Fase de extracci...

Страница 13: ...a blanca Affinity Pro 2 2 extra 53401 b6 Biberón Affinity Pro de 5 oz 150 ml 2 50414 c Anillo 2 y disco 2 del biberón Affinity Pro 50406 d Adaptador cable de CA Affinity Pro 50409 e Base de biberón Affinity Pro 2 53404 Se incluyen dos válvulas blancas adicionales Puede adquirir por separado copas de succión de mayor tamaño Para solicitar piezas de repuesto o copas de succión de mayor tamaño llame ...

Страница 14: ...de extracción de leche materna por primera vez desármelo y hierva por 10 minutos todas las piezas que entran en contacto con la leche incluye b1 b2 b3 b4 b5 y b6 Nota Asegúrese de usar agua suficiente para mantener todas las piezas a flote durante el hervor Nota No hierva el tubo ni su conector 2 Retire todas las piezas del agua inmediatamente después de hervirlas 3 Séquelas completamente antes de...

Страница 15: ...veces durante su sesión de extracción si presiona el botón de estimulación extracción Cuánto debe durar la extracción Si en lugar de la extracción individual utiliza la doble disminuirá el tiempo que dedica a la extracción La producción de leche materna depende de la demanda por eso si extrae su leche regularmente su cuerpo estará estimulado y usted podrá mantener su suministro de leche Como suced...

Страница 16: ... el adaptador de CA suministrado con el producto Ver la sección Datos técnicos en la página 32 33 Modo de uso del extractor Affinity Puede cambiar el ritmo de extracción del extractor presionando el botón Modo del ritmo de extracción Al presionar este botón cambiará el modo del ritmo de extracción Todas las mamás son diferentes es por ello que hemos establecido tres ritmos de extracción distintos ...

Страница 17: ...terna en la puerta del congelador La puerta tiende a ser el lugar menos frío del congelador Anote la fecha en el recipiente y utilice primero la leche que lleva más tiempo en el congelador Descongelamiento de la leche Descongele la leche en la nevera o coloque el recipiente debajo de un chorro de agua fría y entibie la temperatura del agua gradualmente hasta que la leche se descongele La leche des...

Страница 18: ...zas que no sean de Lansinoh pueden anular esta garantía EN LA MEDIDA EN QUE LA LEY LO PERMITA LANSINOH NO SE RESPONSABILIZARÁ POR NINGÚN DAÑO INCIDENTAL O INDIRECTO LO CUAL INCLUYE PERO NO SE LIMITA AL COSTO DE REEMPLAZO RESULTANTE DE LA INFRACCIÓN DE ALGUNA GARANTÍA ESCRITA O IMPLÍCITA Si desea presentar una reclamación en virtud de esta garantía deberá devolver el producto a Lansinoh Laboratorie...

Страница 19: ...gún problema con este producto sírvase llamar gratis a la línea de servicio al cliente al 800 292 4794 Nuestro representante tendrá mucho gusto de ayudarle Distributed by Distribuido por Lansinoh Laboratories Inc Alexandria VA 22314 USA 800 292 4794 Lansinoh com Lansinoh is a registered trademark of Lansinoh Laboratories Inc 2012 Lansinoh Laboratories Inc All rights reserved Printed in Turkey Lans...

Отзывы: