background image

www.lanpro.com

Active Products - Switches - LP-SGW2400

10

4.4 RSTP Port Status

Display the port RSTP Port Status.

Figure 19

4.5 IGMP Status

Display IGMP Status.

Figure 20

Type of diagnostics. 

“Full”

 comprises cable length and full 

anomaly  check, 

“anomaly”

  comprises  full  anomaly  check 

and 

“termination”

 comprises anomaly check without check 

for coupling between pairs (default: full).

4.6 VeriPHY

Figure 21

4.7 Ping

The  ping  function  is  to  test  the  connectedness  of  the  link 
between the switch and destination.

Figure 21b

Содержание LP-SGW2400

Страница 1: ...com LPSGW2400_UG_ENB01W LP SGW2400 24 ports 10 100 1000 24 ports Remote Web Manageable Smart Switch 10 100 1000 Mbps SNMP capable LP SGW2400 24 ports 10 100 1000 24 ports Remote Web Manageable Smart S...

Страница 2: ...ndwidth control function Supports QoS function Supports port based access control support IEEE 802 1X Supports source IP lter per port to block unwanted access Supports broadcast storm smart control f...

Страница 3: ...of the switch the other end is connected with the NIC card and router If the power of the switch is on the related indicators are on Every port of the switch can be used as Uplink port Note Don t plug...

Страница 4: ...t the relative items according to your demands the more detailed guide will be mentioned in the later chapters will take the 24Port Switch as sample 3 2 System Figure 3 System Display current switch s...

Страница 5: ...16 VLAN groups for 802 1q VLAN VLAN group setting the port can communicate only when it is set to the same VLAN goup a port can belong to a multi VLAN group and can communicate with a multi Vlan group...

Страница 6: ...a way to set up aggregation automatically between switches Figure 7 3 7 RSTP RSTP is a protocol that prevents loops in the network and dynamically recon gures which physical links in a switch should f...

Страница 7: ...r VLAN The switch must be setup for IP management in order for the querying to work Figure 10 3 10 Mirroring Port mirror function can transfer a monitored package means the received and sent or sendin...

Страница 8: ...68 kbps Notice If the chosen speed is higher than the practical speed the status column will display the chosen No but not the practical speed Figure 14 3 14 Storm Control Storm Control Can Prevent th...

Страница 9: ...1 Statistics Overview Display all the port current Transmit information and Receive information Figure 16 4 2 Detailed Statistics Display the port current Transmit detailed information and Receive de...

Страница 10: ...tus Figure 20 Type of diagnostics Full comprises cable length and full anomaly check anomaly comprises full anomaly check and termination comprises anomaly check without check for coupling between pai...

Страница 11: ...o the switch window again after you restore factory default con guration If you once changed the default IP address before restore please use the new IP address of you set Figure 23 5 3 Software Uploa...

Страница 12: ...IP Dot1X Debug At top level you may enter a command by giving the full command string including group or you may change context into a group by entering the name of the group At group level you may en...

Страница 13: ...speci c command the command syntax and a description of the command are shown 6 5 Example 1 The command hierarchy and the help utility is demonstrated in the following example enter Figure 30 System S...

Страница 14: ...in this example we wish to reset the switch values to factory settings hence we input System and then Enter In order to take a look at the sublevel values we enter and then enter We will be able to lo...

Отзывы: