Electrical equipment generates heat. Ambient air temperature may not be adequate to cool equipment to 
acceptable operating temperatures without adequate circulation. Be sure that the room in which you 
choose to operate your system has adequate air circulation.   

 

Ensure that the chassis cover is secure. The chassis design allows cooling air to circulate effectively. An 
open chassis permits air leaks, which may interrupt and redirect the flow of cooling air from internal 
components. 

 

Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD damage occurs 
when electronic components are improperly handled and can result in complete or intermittent failures. 
Be sure to follow ESD-prevention procedures when removing and replacing components to avoid these 
problems.   

 

Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. If no wrist strap is available, 
ground yourself by touching the metal part of the chassis. 

 

Periodically check the resistance value of the antistatic strap, which should be between 1 and 10 
megohms (Mohms).   

 

 

 

L’équipement électrique génère de la chaleur. La température ambiante peut ne pas 

être adéquate pour 

refroidir l’équipement à une température de fonctionnement acceptable sans circulation adaptée. Vérifiez 
que votre site propose une circulation d’air adéquate. 

 

 

Vérifiez que le couvercle du châssis est bien fixé. La conception du châssis 

permet à l’air de 

refroidissement de bien circuler. Un châssis ouvert laisse l’air s’échapper, ce qui peut interrompre et 
rediriger le flux d’air frais destiné aux composants internes. 

 

 

Les décharges électrostatiques (ESD) peuvent endommager l’équipement 

et gêner les circuits électriques. 

Des dégâts d’ESD surviennent lorsque des composants électroniques sont mal manipulés et peuvent 
causer des pannes totales ou intermittentes. Suivez les procédures de prévention d’ESD lors du retrait et 

du remplacement de composants. 

 

Portez un bracelet anti-

ESD et veillez à ce qu’il soit bien au contact de la peau. Si aucun bracelet n’est 

disponible, reliez votre corps à la terre en touchant la partie métallique du châssis. 

 

Vérifiez régulièrement la valeur de résistance du bracelet antistatique, qui doit être comprise entre 1 et 10 
mégohms (Mohms).   

 

Mounting Installation Precautions 

The following should be put into consideration for rack-mount or similar mounting installations:

 

 

Do not install and/or operate this unit in any place that flammable objects are stored or used in.   

 

The installation of this product must be performed by trained specialists; otherwise, a non-specialist might 

create the risk of the system’s falling to the ground or other damages. 

 

 

Lanner Electronics Inc. shall not be held liable for any losses resulting from insufficient strength for 
supporting the system or use of inappropriate installation components. 

 

Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient 
temperature of the rack environment may be greater than room ambient. Therefore, consideration should 
be given to installing the equipment in an environment compatible with the maximum ambient 
temperature (Tma) specified by the manufacturer.   

 

Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of airflow 
required for safe operation of the equipment is not compromised.   

 

Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition 
is not achieved due to uneven mechanical loading.   

 

Circuit Overloading - Consideration should be given to the connection of the equipment to the supply 
circuit and the effect that overloading of the circuits might have on overcurrent protection and supply 
wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this 
concern. 

Содержание NCA-5310

Страница 1: ...NCA 5310 User Manual 1 NCA 5310 User Manual Version 1 2 Date of Release 2021 08 26 Industrial Embedded Platforms...

Страница 2: ...ent font types and icons in order to make selected text more transparent and explicable to users Please note that this document contains the following conventions Example Convention Usage iptables F M...

Страница 3: ...e support is offered to our customers in the United States and Canada Toll free customer service number 1 855 852 6637 This document is copyrighted 2021 by Lanner Electronics Inc All rights are reserv...

Страница 4: ...orm Tech Co Ltd Guodong LOFT 9 Layer No 9 Huinan Road Huilongguan Town Changping District Beijing 102208 China T 86 010 82795600 F 86 010 62963250 E service ls china com cn USA Lanner Electronics Inc...

Страница 5: ...interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a c...

Страница 6: ...ions dangereuses sont pr sentes Ne consid rez jamais que l alimentation est coup e d un circuit v rifiez toujours le circuit Cet appareil g n re utilise et met une nergie radiofr quence et s il n est...

Страница 7: ...auser des pannes totales ou intermittentes Suivez les proc dures de pr vention d ESD lors du retrait et du remplacement de composants Portez un bracelet anti ESD et veillez ce qu il soit bien au conta...

Страница 8: ...the grounding cable of the equipment Proper grounding grounding is very important to protect the equipment against the harmful effects of external noise and to reduce the risk of electrocution in the...

Страница 9: ...45 of the National Electrical Code and NFPA 75 Peut tre install dans des salles de mat riel de traitement de l information conform ment l article 645 du National Electrical Code et la NFPA 75 The mach...

Страница 10: ...otherboard Information 16 Opening the Chassis 24 Installing the CPU 24 Installing the Disk Drive s 27 Installing the TPM Module 29 Installing the NIC Modules 30 Installing the IPMI card 32 Installing...

Страница 11: ...NCA 5310 User Manual 11 Security 67 Save and Exit Menu 71 AMD CBS 73 AMD PBS Option 82 Event Logs 83...

Страница 12: ...s 1x Console cable 1x LAN Cable Grey 2x SATA cable SKU No Main Features NCA 5310A AMD EYPC 7000 Series w Support for Naples up to 32C64T and Rome up to 64C128T 1x GbE RJ45 4x NIC Module Slots 1x Conso...

Страница 13: ...e Power Button 1 x ATX Power Switch Console 1 x RJ45 USB 2 x USB 3 0 LCD Module N A Display AC Power Inlet on PSU Storage HDD SSD Support 2 x 2 5 Bays Onboard Slots 1 x 22110 2280 M 2 Slot Expansion P...

Страница 14: ...iption F1 Reset button For software reset F2 LED Indicators F3 USB Ports 2x USB 3 0 F4 RJ45 Port 1x RJ45 port F5 Console Port 1x Console port F6 NIC Module Slot 4x NIC Slots F4 F1 F2 F3 F5 System Powe...

Страница 15: ...NCA 5310 User Manual 15 No Description R1 Power Supply 2 x 800W Redundant PSU R2 Fans 5 x Hot swappable Cooling Fans R3 Power Switch 1 x Power Button R1 R2 R3...

Страница 16: ...NCA 5310 User Manual 16 The block diagram indicates how data flows among components on the motherboard Please refer to the following figure for your motherboard s layout design...

Страница 17: ...NCA 5310 User Manual 17 The motherboard layout shows the connectors and jumpers on the board Refer to the following picture as a reference of the pin assignments and the internal connectors...

Страница 18: ...on them so that they become SHORT To make the pins setting OPEN simply remove the jumper cap 2 pin Header 3 pin Header 4 pin Header Open Short Open 1 2 Jumped Open 1 2 Jumped JUSB1 USB2 0 Pin No Desc...

Страница 19: ...ption 1 GND 2 GND 3 P3V3 4 P12V JATXP12V 4 pin Power Connector Reserve Pin No Description Pin No Description 1 GND 2 GND 3 P12V 4 P12V JSATA1 JSATA4 SATA Pin No Description 1 GND 2 TX_P 3 TX_N 4 GND 5...

Страница 20: ...C_PRX_P7 8 X 9 GND 10 M 2_LED_N 11 PCIE_PTX_M2RX_N7 12 P3V3 13 PCIE_PTX_M2RX_P7 14 P3V3 15 GND 16 P3V3 17 PCIE_M2TX_C_PRX_N6 18 P3V3 19 PCIE_M2TX_C_PRX_P6 20 X 21 GND 22 X 23 PCIE_PTX_M2RX_N6 24 X 25...

Страница 21: ...BMC_COM2_RX 4 BMC_COM2_RTS 5 BMC_COM2_TX 6 BMC_COM2_CTS 7 8 9 IO_GND2 10 P5V JPMB1 PMBUS Pin No Description Pin No Description 1 P3V3_SB 2 3 ATX_PSON 4 GND 5 ATXPWGD 6 PMBUS_CLK 7 PMBUS_DAT 8 PMBUS_A...

Страница 22: ...3V3 A2 GND B3 P3V3 A3 P0_UART0_RXD B4 P0_SPD_SMBUS_CLK A4 IOBAORD_DETECT B5 P0_SPD_SMBUS_CLK A5 P0_UART0_CTS_L B6 P0_SPD_SMBUS_CLK A6 P0_UART0_RTS_L B7 P0_SPD_SMBUS_CLK A7 USB_OC 0 B8 LED_GRN_STATUS A...

Страница 23: ...NTX_N10 B29 USB20_N1 A29 GND B30 GND A30 X B31 USB3_HTX_DRX_N0 A31 X B32 USB3_HTX_DRX_P0 A32 X B33 GND A33 X B34 USB3_HRX_DTX_N0 A34 X B35 USB3_HRX_DTX_P0 A35 X B36 GND A36 GND B37 USB3_HTX_DRX_N1 A37...

Страница 24: ...the processor on your own If handling the processor on your own is inevitable please read through the instructions in this section and refer to the official tutorial released by Intel to make sure you...

Страница 25: ...n the screws that secure metal frame in the sequence of 3 2 1 using the T20 torque 2 Once 1 screw is loosened the metal frame will pop up by itself 3 Gently lift the inner frame by the blue tab and pu...

Страница 26: ...sert the CPU Make sure the alignment corner marked on the CPU matches that of the metal frame When securing the metal frame fasten the screws in the sequence of 1 2 3 5 Secure the heat sink onto the C...

Страница 27: ...isk drive installation procedures based on their HDD SSD designs 1 Power off the system 2 Locate the 2 5 disk bay on the front panel 3 Loosen the screw that fixes the tray onto the motherboard 4 Mount...

Страница 28: ...5 Install the tray back to the original position with the screw Make sure the notch of the tray s side engages properly into the pin as shown in the picture 6 Connect the SATA cable and SATA power cab...

Страница 29: ...NCA 5310 User Manual 29 1 Locate the TPM socket 2 Carefully insert the TPM Make sure the alignment corner marked on the motherboard matches that of the TPM 1...

Страница 30: ...follow the steps for installation 1 On the front panel select a NIC Ethernet module slot 2 Rotate clockwise and loosen the two lock screws 3 Remove the door and locate the socket for module insertion...

Страница 31: ...A 5310 User Manual 31 4 Insert the NIC module The module shown in the image below is for reference only 2 Once the module is firmly seated rotate counter clockwise and tighten the two lock screws 4 5...

Страница 32: ...or installing an IPMI card 1 Locate the IPMI socket Align the notch of the card with the socket key in the slot 2 Insert the module at 30 degrees into the socket until it is fully seated in the connec...

Страница 33: ...em 2 Pull open the DIMM slot latches 3 Align the notch of the module with the socket key in the slot and carefully insert the card into the slot 4 Push the module down into the slot until it is firmly...

Страница 34: ...the steps below to install it 1 Locate the M 2 slot 2 Align the notches of the module with the socket keys in the slot and insert it at 30 degrees into the socket until it is fully seated in the conne...

Страница 35: ...screws that secure the fan 2 Take out the worn fan and disconnect its power cable connector from the motherboard 3 Install a new fan by reversing the above steps Power supply units wear down eventual...

Страница 36: ...ching the Rail Brackets 2 Unpack a slide rail and slide the Inner Channel all the way to the end 3 Stretch the Rail Bracket to the fullest 4 Remove the Rail Bracket from the Inner Channel by pushing t...

Страница 37: ...locked into the four screw holes as shown in the picture 7 Repeat Steps 5 6 to attach the Rail Bracket to the other side of the chassis Assembling the Ear Brackets 1 Check the package contents which...

Страница 38: ...les on the rack front and snap the rail front into the rack post as shown in the image You should hear a click sound once it is firmly attached 2 For the rear rack installation slide the rail to aim a...

Страница 39: ...facing you lift the chassis and gently engage the Rail Brackets on the model while aligning them with the slide rail assemblies as shown in the image and then push the system into the cabinet While p...

Страница 40: ...p screen for instance Main Advanced Chipset Security Boot Save Exit AMD CBS AMD PBS Option Event Logs select an item option on a setup screen Enter select an item option or enter a sub menu to adjust...

Страница 41: ...rnel version CRB code base X64 Compliancy UEFI version PI version Project Version BIOS release version Build Date and Time MM DD YYYY Access Level Administrator User System Date To set the Date use Ta...

Страница 42: ...NCA 5310 User Manual 42 Select the Advanced menu item from the BIOS setup screen to enter the Advanced setup screen Users can select any of the items in the left frame of the screen...

Страница 43: ...Options Description Security Device Support Enabled Disabled Enables or disables BIOS support for security device By disabling this function OS will not show Security Device TCG EFI protocol and INT1A...

Страница 44: ...isables Security Device NOTE Your computer will reboot during restart in order to change State of the Device Pending operation None TPM Clear Schedules an Operation for the Security Device NOTE Your c...

Страница 45: ...NCA 5310 User Manual 45 Trusted Computing TPM2 0...

Страница 46: ...Platform Hierarchy Storage Hierarchy Enabled Disabled Enables or disables Storage Hierarchy Endorsement Hierarchy Enabled Disabled Enables or disables Endorsement Hierarchy TPM2 0 UEFI Spec Version TC...

Страница 47: ...NCA 5310 User Manual 47 Feature Description PSP Firmware Versions PSP Recovery BL Ver SMU FW Version ABL Version PSP BootLoader Version SMU Version ABL Version...

Страница 48: ...NCA 5310 User Manual 48...

Страница 49: ...NCA 5310 User Manual 49...

Страница 50: ...NCA 5310 User Manual 50 Feature Options Description Watch Dog Timer Enabled Disabled Watch Dog Timer Enable or Disable...

Страница 51: ...NCA 5310 User Manual 51 Feature Options Description Control Legacy PXE Boot from Enabled Disabled PXE Enable or Disable...

Страница 52: ...NCA 5310 User Manual 52 Feature Options Description Consol Redirection Enabled Disabled Enables or disables Console Redirection...

Страница 53: ...ser Manual 53 Feature Options Terminal Type VT100 VT100 VT UTF8 ANSI Bits per second 9600 19200 38400 57600 115200 Data Bits 7 8 Parity None Even Odd Mark Space Stop Bits 1 2 Flow Control None Hardwar...

Страница 54: ...NCA 5310 User Manual 54 VT UTF8 Combo Key Support Disabled Enabled Recorder Mode Disabled Enabled Resolution 100x31 Disabled Enabled Putty KeyPad VT100 LINUX XTERM86 SCO ESCN VT400...

Страница 55: ...NCA 5310 User Manual 55...

Страница 56: ...NCA 5310 User Manual 56 Feature Options Description SVM Mode Disabled Enabled Enable disable CPU Virtualization SMEE Disabled Enabled Control secure memory encryption enable...

Страница 57: ...NCA 5310 User Manual 57 Node 0 Information Node 1 Information...

Страница 58: ...bled If system has SR IOV capable PCIe Devices this option Enables or Disables Single Root IO Virtualization Support BME DMA Mitigation Disabled Enabled Re enable Bus Master Attribute disabled during...

Страница 59: ...This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver USB Mass Storage Driver Support Enabled Disabled Enables or disables USB Mass Sto...

Страница 60: ...B mass storage device Start Unit command time out Device power up delay Auto Manual Maximum time the device will take before it properly reports itself to the Host Controller Auto uses default value f...

Страница 61: ...trols the execution of UEFI and Legacy PXE OpROM Storage Do Not Launch UEFI Legacy Controls the execution of UEFI and Legacy Storage OpROM Video Do Not Launch UEFI Legacy Controls the execution of UEF...

Страница 62: ...NCA 5310 User Manual 62...

Страница 63: ...NCA 5310 User Manual 63...

Страница 64: ...NCA 5310 User Manual 64 Select the Chipset menu item from the BIOS setup screen to enter the Platform Setup screen Users can select any of the items in the left frame of the screen...

Страница 65: ...NCA 5310 User Manual 65...

Страница 66: ...NCA 5310 User Manual 66...

Страница 67: ...Administrator s password is set it only limits access to Setup and is only asked for when entering Setup User Password If ONLY the User s password is set it serves as a power on password and must be e...

Страница 68: ...t Disabled Enabled Secure Boot is activated when Platform Key PK is enrolled System mode is User Deployed and CSM function is disabled Secure Boot Mode Standard Custom Secure Boot mode selector In Cus...

Страница 69: ...ows User to provision factory default Secure Boot keys when System is in Setup Mode Install Factory Default keys None Forces System to User Mode install all Factory Default keys Enroll Efi Image None...

Страница 70: ...ans indefinite waiting BootupNumLock State On Off Select the keyboard NumLock state Quiet Boot Enabled Disable Enables or disables Quiet Boot option Boot mode select LEGACY UEFI DUAL Select boot mode...

Страница 71: ...em configuration The following window will appear after the Discard Changes and Exit option is selected Select Yes to Discard changes and Exit Setup Save Changes and Reset When Users have completed th...

Страница 72: ...anual 72 Restore Defaults Restore default values for all setup options Select Yes to load Optimized defaults Note The items under Boot Override were not same with image It should depend on devices con...

Страница 73: ...NCA 5310 User Manual 73...

Страница 74: ...te Control Disabled Enabled Controls IO based C state generation and DF C states Power Supply Idle Control Low Current Idle Typical Current Idle Auto Power Supply Idle Control Local APIC Mode xAPIC x2...

Страница 75: ...d for ACS enable to work PCIe ARI Support Disabled Enabled Auto Enables Alternative Routing ID Interpretation PCIe Ten Bit Tag Support Disabled Enabled Auto Enables PCIe ten bit tags for supported dev...

Страница 76: ...to Manual User can set customized CLDO_VDDP voltage EfficiencyModeEn Enabled Auto 0 use performance optimized CCLK DPM settings 1 use power efficiency optimized CCLK DPM settings Package Power Limit C...

Страница 77: ...NCA 5310 User Manual 77...

Страница 78: ...ta RAS Support Disabled Enabled Auto Disable or enable Sata RAS Support Sata Disabled AHCI Prefetch Function Disabled Enabled Auto Disable or enable Sata Disabled AHCI Prefetch Function Aggresive SATA...

Страница 79: ...tion Options Feature Options Description XHCI Controller0 enable Disabled Enabled Auto Enable or disable USB3 controller XHCI Controller1 enable Disabled Enabled Auto Enable or disable USB3 controller...

Страница 80: ...ser Manual 80 MCM USB enable Feature Options Description XHCI2 enable Socket1 Disabled Enabled Auto Enable or disable USB3 controller XHCI3 enable Socket1 Disabled Enabled Auto Enable or disable USB3...

Страница 81: ...NCA 5310 User Manual 81 Feature Options Description Ac Loss Control S5 State S0 State Last State Select Ac Loss Control Method...

Страница 82: ...NCA 5310 User Manual 82 Feature Options Description SPI Locking Disabled Enabled Enable disable SPI Locking for protect ROM part...

Страница 83: ...NCA 5310 User Manual 83...

Страница 84: ...ystem boot event MECI 1 255 Multiple Event Count Increment The number of occurrences of a duplicate event that must pass before the multiple event counter of log entry is updated The value ranges from...

Страница 85: ...NCA 5310 User Manual 85...

Страница 86: ...ense 5 The following conditions are excluded from this warranty Improper or inadequate maintenance by the customer Unauthorized modification misuse or reversed engineering of the product Operation out...

Страница 87: ...NCA 5310 User Manual 87 When requesting RMA service please fill out the following form Without this form enclosed your RMA cannot be processed...

Страница 88: ...ds Use x2APIC scales beyond 255 hardware threads but not supported by some legacy OS versions Use x2APIC only if 256 hardware threads in the system otherwise use xAPIC Note Interrupt delivery is faste...

Страница 89: ...device the Mellanox card is hosted on and set it as this address cTDP Control Advanced NBIO Common Options cTDP Control Manual Set configurable Thermal Design Point by manually Auto Use default confi...

Страница 90: ...ck Advanced UMC Common Options DDR4 Common Options DRAM Timing Configuration Accept Overclock Enable Enable Enable DRAM Timing Configuration Speed Advanced UMC Common Options DDR4 Common Options DRAM...

Страница 91: ...BIOS parameter Recommend by Mellanox sudo set_irq_affinity_bynode sh 0 Run script to optimizing single port traffic When you using signal port recommend by Mellanox sudo ifconfig NIC_Name ex eth0 mtu...