Страница 1: ...Network Application Platforms Hardware platforms for next generation networking infrastructure FW 7525 V1 1 User s Manual Release Date 2015 05 08...

Страница 2: ...E This product has passed the CE test for environmental specifications Test conditions for passing included the equipment being operated within an industrial enclosure In order to protect the product...

Страница 3: ...manual may cause harmful interference to radio communications Operation of this equipment in a commercial area is likely to cause harmful interference in which case users will be required to correct t...

Страница 4: ...la terre en touchant la partie m tallique du ch ssis V rifiez r guli rement la valeur de r sistance du bracelet antistatique qui doit tre comprise entre 1 et 10 m gohms Mohms Consignes de s curit lect...

Страница 5: ...6 Preparing the Hardware Installation 16 Installing the System Memory 16 Installing Disk Drive 16 Installing the CompactFlash Card 17 Installing the Mini PCIe Card 17 Installing FW 7525 on the Wall 18...

Страница 6: ...HA 1 MD5 SHA 2 SHA 224 SHA 256 SHA 384 SHA 512 Authentication HMAC AES XCBC AES CCM and AES GCM Public Key Exchanges RSA DH DSA ECC Form Factor Desktop Platform Processor Options 2 core Intel Atom Pro...

Страница 7: ...TM processor C2518 Code named Rangeley 6 GbE LAN ports with Gen 2 Bypass 60W power adapter FW 7525D Fanless Network Security Appliance with Intel AtomTM processor C2558 Code named Rangeley 6 GbE LAN p...

Страница 8: ...N3 LAN6 GbE ports are provided by Marvell 88E1543 and LAN1 LAN2 are provided by Intel i210AT LAN1 is capable of Preboot eXecution Environment PXE This feature needs to be enabled or disable in the BIO...

Страница 9: ...3 R1 Reset Switch The reset switch can be used to reboot the system without turning off the power R2 ATX Power on button with LEDs Standby mode in Red Power on mode in Green R3 Power in Socket The sys...

Страница 10: ...2 Motherboard Information Block Diagram The block diagram depicts the relationships among the interfaces or modules on the motherboard Please refer to the following figure for your motherboard s layou...

Страница 11: ...connectors and jumpers on the board Refer to the following picture as a reference of the pin assignments and the internal connectors FAN1 LAN6 JBAT1 LAN5 LAN4 LAN3 LAN2 LAN1 USB1 COM1 J20 PKMB1 LPC1 M...

Страница 12: ...D2 10 2 10 1 9 USB Pin Header USB2 It is for connecting the USB module cable It complies with USB2 0 and support up to 480 Mbps connection speed Dual USB 2 0 Ports USB1 This provides two USB 2 0 ports...

Страница 13: ..._N 4 LPC_AD0 5 LPC_FRAME_N 6 P3V3 7 LPC_AD3 8 Key ping 9 LPC_AD2 10 GND 1 2 9 10 1 2 9 10 Clear CMOS jumper JBAT1 It is for clearing the CMOS memory and system setup parameters by erasing the data sto...

Страница 14: ...euing AHCI also provides usability enhancements such as Hot Plug Note You will need to configure your SATA as 1 AHCI mode in the BIOS in order to use the advanced features of SATA To do this access th...

Страница 15: ...GND 9 GND 35 GND 10 NC_UIM_DATA 36 USB_IO3_DN 11 M I N I P C I E _ R E F CLKN 37 GND 12 NC_UIM_CLK 38 USB_IO3_DP 13 MINIPCIE_REFCLKP 39 VCC3 14 NC_UIM_RST 40 GND 15 GND 41 VCC3 16 NC_UIM_VPP 42 NC_LE...

Страница 16: ...on the bottom of 2 the cover of the FW 7525 System Slide the cover backwards to open it 3 Installing the System Memory The motherboard supports DDR3 memory that features data transfer rates of 1333 16...

Страница 17: ...ides one CompactFlash slot Please follow the steps below to install a CompactFlash card 1 Align CompactFlash card and the card slot with the arrow pointing toward the connector The card fits only the...

Страница 18: ...stem on where it will be mounted on the wall You may draw marks for the circled screw holes as the image below for applying wall anchors in later steps Do the same for both sides 5 Apply the 4 white w...

Страница 19: ...Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wir...

Страница 20: ...4 Attach the ears of the L shaped brackets to the rack and then apply long threaded nails Notes rack use screws and nuts are not supplied in the mounting kit 5 Repeat Step 4 for another side...

Страница 21: ...on on the system chassis You can also restart by turning the system off and then back on Do this last option only if the first two failed The Setup program is designed to make it as easy to use as pos...

Страница 22: ...e right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a text message will acco...

Страница 23: ...e Arrow keys All Advanced BIOS Setup options are described in this section The Advanced BIOS Setup screen is shown at the right The sub menus are described on the following pages PXE Function The Preb...

Страница 24: ...Super IO configuration Serial Port 0 1 Configuration Item Selection Serial Port Enable or disable this serial port Device Settings Shows the serial port base address and the IRQ port...

Страница 25: ...iguration options PC Health Status SYSIN1 SYSIN2 SYSIN3 Temperature The onboard hardware monitor automatically detects and displays the CPU and motherboard temperatures CPU Voltage 1V voltage 5V volta...

Страница 26: ...able BIOS through remote access Console Redirection Settings Enter to view more op tions COM0 Console Redirection Settings Item Selection Terminal Type Sets the connection ter minal type Bits per seco...

Страница 27: ...es of LAN bypass configuration in each state Note that according to the result from table 2 the ports are not bypassed in both system on or system off state when the setting System off LAN Bypass for...

Страница 28: ...s fully booted with all USB drivers loaded When this option is enabled any attached USB mouse or USB keyboard can be used on the system even when there is no USB drivers loaded on it Option Descriptio...

Страница 29: ...this case the transfer waits indefinitely until it is manually canceled or the transfer completes normally If set to a nonzero value time out interval the host controller starts a timer when it receiv...

Страница 30: ...ology EIST It allows the operating system to dynamically adjust the processor voltage and cores frequency result ing to a decreased average power consumption and decreased average heat production TM1...

Страница 31: ...n setting to Power Off the system goes into off state after an AC power interruption Power On When setting to Power on the system turns on automatically after a power interruption Auto When setting to...

Страница 32: ...r Serial ATA Port 0 1 Use this menu to configure specific SATA Port for all ports on the system Option Description Spin Up Spin up is a simple mechanism by which the storage subsystem controller can s...

Страница 33: ...word you must enter the user password for booting and accessing the system however some functions may be disabled To set an Administrator User password Select the option item and press Enter 1 From th...

Страница 34: ...or the boot setup prompt to wait for user s intervention during the POST Bootup Num Lock State This option lets you to enable or disable the function of the NumLock key Quiet Boot Enabling this item a...

Страница 35: ...ter so the new system configuration parameters can take effect Discard Changes and Reset This option allows you to discard the selections you made and restore the previously saved values After selecti...

Страница 36: ...anual CD Appendix B Setting up Console Redirections Console redirection lets you monitor and configure a system from a remote terminal computer by re directing keyboard input and text output through t...

Страница 37: ...menu as shown below There are two ways to enable the bypass on the system The LAN bypass can be turned on or off in two system states i e power on 1 Runtime Bypass and power off System Off Bypass The...

Страница 38: ...ass A watchdog timer can be used to control the LAN Bypass function dynamically by 1 programming Lanner also provides sample code for bypass control with WDT via programming For sample code look in th...

Страница 39: ...h Authenticate Operation Cipher Hash Combined Operation Key Derivation Operation Public Key Functions RSA Operation Diffie Helman Operation Digital Signature Standard Operation Key Derivation Operatio...

Страница 40: ...se The following conditions are excluded from this 5 warranty Improper or inadequate maintenance by the customer Unauthorized modification misuse or reversed engineering of the product Operation outsi...

Страница 41: ...Others ________________ Item Model Name Serial Number Configuration Item Problem Code Failure Status Problem Code 01 D O A 02 Second Time R M A 03 CMOS Data Lost 04 FDC Fail 05 HDC Fail 06 Bad Slot 0...