10 - 35
LANGER
EMV-Technik
DE-01728 Bannewitz
[email protected]
www.langer-emv.com
P1202 / P1301 L-ESD set
BPM 02 dB/dt Field Meter
4.6
Frequency range
500 kHz - 3 GHz
Magnetic flux density
B
calculation based on the voltage
u
out
at the measurement output
Ḃ = K ∙ u
out
K = 122 dB (
T
V ∙ s
)
B = (1 ω
⁄ ) Ḃ
B = Ḃ − 20 log
10
(ω)
Table 6: Conversion factor of BPM 02
EPM 02 dE/dt Field Meter
4.7
Frequency range
500 kHz - 3 GHz
Electric field strength
𝐸
calculation based on the voltage
u
out
at the measurement output
Ė = K ∙ u
out
K = 251 dB (
1
cm ∙ s
)
E = (1 ω
⁄ ) Ė
𝐸 = Ė − 20 𝑙𝑜𝑔
10
(𝜔)
Table 7: Conversion factor of EPM 02
BPS 203 Burst Power Station
4.8
Frequency range
0.1 Hz
– 30 Hz
Output voltage
± (0.1 ... 9) kV
Supply voltage
12 V / 1 A DC
Interface
USB
Weight
350 g
Sizes (L x W x H)
(175 x 122 x 61) mm
Software
BPS 203-client
Table 8: BPS 203 technical parameters