19 / 26
3.4.10.1 User setting - h parameters
Table 2: h parameters
Parameter Function
Min.
value
Default
value
Max.
value
Factor Unit
hA
Activation
Additional dri-
ve
Only for use with optional add on
boards (valid from version TSG
V4).
00: Opportunity to move to the
intermediate position and Ready
For Operation (usable with add
on board 4E/4A relais or 4E/4A
electronic)
01: interlock or skate drive
(e.g. QKS6, usable with add on
board additional drive)
02: retiring cam magnet (e.g.
KONE ADC, usable with add on
board additional drive)
03: interlock with emergency
power supply (e.g. Koch, usable
with add on board additional
drive)
04: enabling mode (usable with
add on board 4E/4A electronic)
05: external sensor, two channel
(usable with add on board 4E/4A
electronic)
06: interlock drive for shaft
hinged doors (usable with add
on board additional drive)
00
00
18
hb
Closing time
of the skate
Only with additional board that
can be optionally fitted and
hA=01, hA=03 or hA=06.
Caution:
If the value of h7 = 00, then the
value of hb is for opening and
closing time of the skate.
00
50
80
[1/100
seconds]
hC
Time delay
between
opening of the
drive and
opening of the
door
Only with additional board that
can be optionally fitted and
hA=01, hA=03 or hA=06.
01
50
99
[1/100
seconds]
h7
Opening time
of the skate
Only with additional board that
can be optionally fitted and
hA=01 or hA=03
Caution:
If the value of h7 = 00, then the
value of hb is for opening and
closing time of the skate.
00
00
80
[1/100
seconds]