background image

 

 
 

 

11 / 26 

 
 

3.2  Safety Equipment 

 

CAUTION: 

All the safety regulations listed in EN81 must still be observed after modifying the new door 
machine. 
 
 
 

In the case of a telescopic lift door, it should be noted that the door panel has a door interlock. 
Extract from EN81-1: 
Ch. 8.10 Lift-compartment sliding doors with several mechanically linked door panels 
8.10.1 In the case of lift-compartment sliding doors with several directly mechanically interlinked door pan-
els, it is permissible, 

a)

  to attach the installation as per 8.9.2 

1.  either only on one door panel (the fastest one in the case of telescopic doors) 
2.  or on the door drive, as long as there is a form-fitting link between the drive element and the door 

panels,, 

and 

b)  in the event of locking only one door panel and in accordance with the conditions as per 11.2.1 c, if 

this one interlock prevents the opening of the other door panels due to their intermeshing with each 
other in the closed position. 

 
When attaching and commissioning the TSG in/on a lift cabin, it must be ensured that the maximum per-
mitted total weight of the lift cabin is not exceeded under maximum rated load. 
 
In the event of an emergency stop or shut-down of the lift, it must be ensured that the TSG door-control 
unit does not cause any unintentional, dangerous or uncontrolled door movements. 
 
 

CAUTION: 

The simulated limit switch for “Door open”, “Door closed” and “Door blocked” on the control-
ler for the door and locking bar drive must not be used as safety equipment with any safety 
relevance. 
 
 

 

3.3  Car door lock 

 
WARNING: 

The Schindler QKS6/9 car door lock 

is not

 compatible with the Langer & Laumann  

modernization packages and 

is not

 supported! 

 

 

Содержание QKS6

Страница 1: ...1 26 User Manual for QKS6 L L door operator conversion...

Страница 2: ...end to include copies which are created for third parties and sold to or in any other way conveyed to same Nevertheless the entire acquired material including all backup copies can be sold to handed o...

Страница 3: ..._________________________ 8 2 3 Scope of Delivery ______________________________________________________________ 9 2 4 Description of Product Functions ________________________________________________...

Страница 4: ...cuments It is prohibited to reproduce them make them available to third parties or to use them in any other unauthorised manner without our prior agree ment Changes require our express prior and writt...

Страница 5: ...g danger of serious physical damage or death CAUTION This sign is to indicate a possible impending danger of light physical damage This sign is also to warn you of material damage NOTE You will be inf...

Страница 6: ...6 26 2 General 2 1 Summary Sketch Abb 1 QKS6 L L door operator telescoping right Abb 2 QKS6 L L door operator centre...

Страница 7: ...7 26 Abb 3 QKS6 L L door operator centre telescoping...

Страница 8: ...iguration 2 panel telescoping left 2 panel telescoping right 2 panel telescoping centre 4 panel telescoping centre 0700 X X X 0800 X X X 0900 X X X 1000 X X X 1100 X X X 1200 X X X X 1300 X X X X 1400...

Страница 9: ...ngs as well as the encoder must not be damaged by pumping 2 4 Description of Product Functions All the door drives operate according to the same function principle The doors are activated by a DC mo t...

Страница 10: ...it switches as well as the door pusher dogs The existing shaft door actuator for shaft opening remains intact in principle but requires an additional ac tuator As all the assembly steps for the 2 pane...

Страница 11: ...f locking only one door panel and in accordance with the conditions as per 11 2 1 c if this one interlock prevents the opening of the other door panels due to their intermeshing with each other in the...

Страница 12: ...track has the same length and mass as the old one 3 4 2 Disassembly the old door operator The old door drive must be dismantled completely The clamping plates at the old door drive must be un screwed...

Страница 13: ...de on the exterior wall of the cab With both types of fasteners the mountings have been pre assembled on the frame their respective spacing can be moved horizontally and is infinitely variable Abb 4 V...

Страница 14: ...help of the door roller supports 3 4 6 Safety contact Control the safety contact at door operator and fix the actuator for safety contact on door roller Abb 5 safety contact by QKS6 L L telescoping ri...

Страница 15: ...serves as a stop and stops the panel in open and close di rection Control the limit stop buffer in closed and opened position 3 4 8 Slow panel The slow panel hang up with the help of the door roller s...

Страница 16: ...actuator Dismantle old lever Clean and fit to handle the new shaft door actuator Drill holes for the safety contact bridge Install the new shaft door actuator at the panel Connect contact safety circu...

Страница 17: ...17 26 NOTE Before mounting the shaft door actuator must be 2 holes in the door be drilled A match ing template is included Abb 10 Processing door drilling pattern...

Страница 18: ...r installed in new shaft door actuator Abb 12 old shaft door actuator mounted Abb 13 Removed from the old lever shear Abb 14 Delivery condition shaft door actuator Abb 15 safety contacts on the new sh...

Страница 19: ...le with add on board 4E 4A electronic 05 external sensor two channel usable with add on board 4E 4A electronic 06 interlock drive for shaft hinged doors usable with add on board additional drive 00 00...

Страница 20: ...er hA NOTE For additional information on parameter settings see the TSG door control device manual 3 4 10 4 Opening and closing time of Sinus Drive The opening and closing time of the Sinus Drive can...

Страница 21: ...e drive first moves the shaft door actuator apart and then the door moves up Parameter hC can be adjusted for this purpose 3 4 11 Technical data for TSG electronics 3 4 11 1 Overview of TSG drive expa...

Страница 22: ...e 1 X1 drive 1 3 pin screw connector 1 Connection 1 2 Connection 2 PE PE Table 4 TSG expansion board X2 drive 2 X2 drive 2 3 pin screw connector 1 Connection 1 2 Connection 2 PE PE Table 5 TSG expansi...

Страница 23: ...purposes Abb 16 QKS6 L L with ribbon cable 3 4 13 Console for housing You can fit the TSG electronic board plus IP54 housing with the console on the back of the door operator see Abb 17 console for h...

Страница 24: ...eight must not bounce The cab doors and all the shaft doors must move easily The toothed belts must be taut one should only be able to depress it in the centre by two fingers The connector rail X1 inp...

Страница 25: ...cles One cycle corresponds to one extension movement plus one retraction movement of the Sinus Drive a high performance lift can be presumed to complete approx 800 000 cycles per year As part of servi...

Страница 26: ...act You can reach us at the following address with any questions or queries Langer Laumann Ing B ro GmbH Wilmsberger Weg 8 48565 Steinfurt Germany Phone 49 2552 92 7 91 0 Email info LuL Ing de Web www...

Отзывы: