5
INSTALLATION
CAUTION:
UNIT IS EXTREMELY HEAVY. FOR SAFE HANDLING, INSTALLER
SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE
MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY,
OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND
MOVE IT TO THE PLACE OF INSTALLATION.
WARNING:
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL
QUALIFIED TO WORK WITH PLUMBING. IMPROPER INSTALLATION
CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO
EQUIPMENT. UNIT MUST BE INSTALLED IN ACCORDANCE WITH
ALL APPLICABLE CODES.
CAUTION:
SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK
WHEN CUT.
NOTICE:
The data plate is located on the right side of the unit. The Char broiler
gas specifications are on the data plate. This information should be
carefully read and understood before proceeding with the installation.
WARNING:
BEFORE LIGHTING, USE A SOAP AND WATER SOLUTION TO TEST
ALL JOINTS FOR GAS LEAKS.
NOTICE:
The installation of any components such as a vent hood, grease
extractors, fire extinguisher systems, must conform to their applicable
National, State and locally recognized installation standards.
2.1 General
All Lang Char broilers are shipped with a gas pressure regulator packed with the unit. All units
are adjusted, tested, and inspected at the factory prior to shipment.
A manual gas shut-off valve must be installed in the gas supply (service) line ahead of the char
broiler and gas pressure regulator for safety and ease of future service.
The gas pressure regulator supplied must be installed on the appliance prior to connecting the
equipment to the gas line. Failure to install a regulator will void the equipment warranty and
result in a potentially hazardous condition.
The appliance and its individual shut off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 PSI.
The appliance must be isolated from the gas supply piping system by closing its individual
manual shut off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 PSI.
2.2 Installation
RATING PLATE
- Information on this plate includes the model and serial numbers. When
communicating with factory about a unit or requesting special parts or information, this data is
essential for proper identification. Other information on this plate is the BTU/hr input of the
burners, operating gas pressure in inches WC, and whether the unit is orificed for natural or
propane gas.
Содержание LRB