9
SERVICE
WARNING
SERVICE ON THIS, OR ANY OTHER LANG APPLIANCE, MUST BE PERFORMED BY
QUALIFIED PERSONNEL ONLY. CONSULT YOUR LANG AUTHORIZED SERVICE STATION
DIRECTORY OR CALL THE FACTORY AT 1-800-224-5264 FOR THE SERVICE STATION
NEAREST YOU.
ALWAYS DISCONNECT THE APPLIANCE FROM POWER AND GAS BEFORE PERFORMING
SERVICE.
ALWAYS CHECK FOR GAS LEAKS WITH A SOAP AND WATER SOLUTION AFTER SERVICE
IS COMPLETED.
NEVER CHECK FOR GAS LEAKS WITH AN OPEN FLAME!
BURNER AIR SHUTTER ADJUSTMENT
GRIDDLE
The air shutters are pre-set at the factory, however, minor adjustments may be required in the field to
accommodate differences in gas and elevation.
The shutter is located on the end of the burner at the orifice fitting.
To adjust the griddle air shutter loosen the set screw holding the shutter to the burner.
Adjust the air mixture until the flame is well defined with an inner and outer cone and just flickers on the
burner face.
"Lift-off" or yellow flame indicates improper shutter adjustment.
Periodically inspect and clean the air shutters to insure complete combustion.
BROILER
The broiler air shutter is pre-set at the factory, however, minor adjustment may be required to
accommodate differences in gas and elevation.
The air shutter plate is located near the top of the right broiler stanchion as viewed from the rear of the
griddle.
Figure 1
Adjust the air shutter plate by loosening the two screws and nuts which hold the shutter to the stationary
mount.
Push the air shutter in until the burner flame becomes a hazy blue cloud. Slide the shutter out until the
burner flame pulls up tight against the ceramic and the tiles turn a bright orange.
Содержание GGB-24
Страница 18: ...15 WIRING DIAGRAM ...